Siemens 3VA9214-0RS20 SENTRON RCD510 Type A 4P 250A 30mA-5A for 3VA1
Doprava zdarma
Získejte dopravu zdarma při objednávce nad 300 €!
The Siemens 3VA9214-0RS20 is a SENTRON RCD510 basic residual current protection module, Type A, designed for side-mounted assembly with 3VA1 molded-case circuit breakers (e.g. 3VA12 Frame 250). It provides 4-pole earth-fault protection rated for 250 A operational current at 127-480 V AC, with selectable residual current thresholds from 30 mA to 5 A and selectable trip delay from 0 to 3000 ms. Includes 30% pre-alarm indication, sealable selectors, and switchable RCD-or-monitoring mode.
Technical specifications:
- Order number (MLFB): 3VA9214-0RS20
- Manufacturer: Siemens
- Product line: SENTRON
- Product type: Residual current protection module, Type A
- Series: RCD510 basic
- Compatible circuit breakers: 3VA1 with terminal connection (e.g. 3VA12 Frame 250)
- Mounting: Side mounted, screw fixing
- Number of poles: 4
- Operational current (Ie): 250 A AC
- Supply voltage (Ue): 127-480 V AC
- Operating frequency: 50/60 Hz (rated max 60 Hz)
- Fault current frequency range: 50-60 Hz
- Adjustable rated residual current (IΔn): 0.03 / 0.05 / 0.1 / 0.3 / 0.5 / 1 / 3 / 5 A
- Adjustable non-tripping time (tv): 0 / 0.06 / 0.15 / 0.3 / 0.5 / 1.0 / 2.0 / 3.0 s
- Pre-alarm indication: Yes, at 30% of IΔn setting
- Selectable RCD or monitoring mode: Yes
- Electrical trip indicator: Yes
- Sealable selectors: Yes
- Infeed position on RCD module: Top or bottom
- Remote tripping: No
- Communication function: No
- IP protection (front): IP40
- Dimensions (H × W × D): 228 × 170 × 70 mm
- Net weight: 1.516 kg
- Ambient temperature during operation: -25 to +70 °C
- Storage temperature: -40 to +80 °C
- Approvals: General Product Approval, EMC, Maritime application, type test, environmental confirmations, dangerous-goods transport information
- EAN/GTIN: 4042949002277
Features and benefits:
- Type A residual current detection - covers pulsating DC fault currents in addition to AC, suitable for modern loads with rectifiers/inverters
- Wide adjustable thresholds 30 mA to 5 A - allows tuning from personal-protection to fire-protection use cases on the same hardware
- Adjustable time delay 0-3 s - selective coordination with downstream RCDs to prevent nuisance tripping
- 30% pre-alarm indication - early warning of insulation degradation before actual trip
- Switchable RCD/monitoring mode - run as a true breaker OR as a monitoring-only relay for fault recording without tripping
- Side-mounted: doesn't increase the breaker footprint depth; preserves panel layout
- Sealable settings - prevent unauthorized tampering with trip thresholds
- Maritime approval - usable on shipboard and offshore distribution
Applications:
- Earth-fault protection on 3VA1 Frame 250 main and feeder circuit breakers in industrial and commercial distribution boards
- Final distribution circuits requiring 30 mA personal protection (additional protection per IEC 60364-4-41)
- Fire prevention applications using 300-500 mA threshold settings
- Selective TT/TN-S systems requiring time-delayed S-type residual current protection
- Plants with frequency converters and rectifier loads where Type A detection is required
- Maritime and shipboard switchboards with earth-fault monitoring requirements
Also known as: Siemens 3VA9214-0RS20, SENTRON RCD510 basic Type A 4P 250A, 3VA1 residual current module 30mA-5A, side-mounted RCD for 3VA12.
Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.
Důležité
Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.