Schneider A9R44263 Acti9 iID RCCB 2P 63A 300mA Type AC

Doprava zdarma

Získejte dopravu zdarma při objednávce nad 300 €!

Vyprodáno
Původní cena €33,13 - Původní cena €33,13
Původní cena
€33,13
€33,13 - €33,13
Momentální cena €33,13

The Schneider A9R44263 is an Acti9 iID residual current circuit breaker (RCCB), rated 2P 63A 300mA Type AC, providing fire protection against earth leakage faults caused by insulation failures. The 300mA sensitivity targets fire protection in residential, commercial and industrial distribution boards, while the Type AC characteristic detects alternating sinusoidal residual currents typical of conventional resistive and inductive loads.

Technical specifications:

  • Part number: A9R44263
  • Manufacturer: Schneider Electric
  • Series: Acti9 iID
  • Type: Residual current circuit breaker (RCCB)
  • Poles: 2 (1P+N)
  • Rated current (In): 63A
  • Rated residual operating current (IΔn): 300mA
  • Trip type: Type AC (alternating sinusoidal residual currents)
  • Rated voltage: 230/240V AC
  • Frequency: 50/60 Hz
  • Rated conditional short-circuit current (Inc): 10kA
  • Rated impulse withstand voltage (Uimp): 6kV
  • Insulation class: II
  • Mechanical endurance: 20,000 operations
  • Electrical endurance: 10,000 operations
  • IP rating: IP20 (terminals), IP40 (front face)
  • Wire cross-section: up to 35 mm² rigid, 25 mm² flexible
  • Operating temperature: -25°C to +60°C
  • Mounting: 35mm DIN rail
  • Modules: 2 (18mm pitch each)

Features and benefits:

  • VisiTrip mechanical fault indicator shows the cause of tripping at a glance
  • VisiSafe positive contact indication confirms true contact separation
  • Double terminal accepts both cables and Acti9 comb busbars without adapters
  • 300mA sensitivity prevents nuisance tripping while protecting against fire hazards from insulation faults
  • Padlockable in OFF position for safe maintenance lockout
  • Compatible with the full Acti9 ecosystem of comb busbars, auxiliary contacts and accessories

Applications:

  • Main incomer protection in residential consumer units
  • Sub-distribution boards in commercial buildings
  • Fire protection in industrial control panels with conventional resistive and inductive loads
  • Earth leakage protection for lighting and heating circuits
  • Selective coordination with downstream 30mA RCBOs for two-level discrimination

Compliant with IEC/EN 61008-1.

Also known as: Schneider iID RCCB 63A 300mA, Acti9 RCCB 2P Type AC, A9R44263 fire protection RCD, Schneider 63A 300mA residual current breaker, A9R44263 Type AC 2-pole.