The Schneider Electric A9F84406 is an Acti9 iC60H miniature circuit breaker, 4-pole, 6 A, C curve. It provides overload and short-circuit protection with a rated breaking capacity of 10000 A (Icn) to EN/IEC 60898-1 and up to 15 kA (Icu) at 380-415 V AC to EN/IEC 60947-2.
Technical specifications:
- Commercial reference: A9F84406
- Manufacturer: Schneider Electric
- Range: Acti9
- Product name: Acti9 iC60
- Device short name: iC60H
- Product type: Miniature circuit-breaker
- Poles: 4P (4 protected poles)
- Rated current (In): 6 A
- Curve code: C
- Trip unit technology: Thermal-magnetic
- Magnetic tripping limit: 8 x In +/- 20 %
- Network type: AC and DC
- Network frequency: 50/60 Hz
- Rated operational voltage (Ue): 12...133 V AC, 220...240 V AC, 380...415 V AC, 440 V AC, <= 250 V DC
- Breaking capacity: 42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2; 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2; 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2; 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
- Limitation class: 3 conforming to EN/IEC 60898-1
- Rated insulation voltage (Ui): 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
- Rated impulse withstand voltage (Uimp): 6 kV conforming to EN/IEC 60947-2
- Utilisation category: Category A conforming to EN/IEC 60947-2
- Suitability for isolation: Yes conforming to EN/IEC 60947-2 and EN/IEC 60898-1
- Mounting: Clip-on on 35 mm DIN rail
- Width in 9 mm pitches: 8
- Dimensions (HxWxD): 85 mm x 72 mm x 78.5 mm
- Product weight: 0.5 kg
- Colour: White
- Mechanical durability: 20000 cycles
- Electrical durability: 10000 cycles
- Connections: Single terminal (top or bottom) , for 1 cable(s) , 1…25 mm², rigid, copper
- Wire stripping length: 14 mm for top or bottom connection
- Tightening torque: 2 N.m top or bottom
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: EN/IEC 60947-2, EN/IEC 60898-1
Features and benefits:
- C curve magnetic trip at 8 x In +/- 20 % for inductive loads such as motors and transformers
- Suitable for isolation to both EN/IEC 60947-2 and EN/IEC 60898-1
- Comb busbar compatible for fast distribution board wiring
- Clip-on mounting to 35 mm DIN rail
Applications:
- Overload and short-circuit protection of final circuits in distribution boards
- Three-phase plus neutral circuits at 380-415 V AC
- Industrial and commercial installations requiring a 10 kA breaking capacity
- Circuits with inductive inrush that would nuisance-trip a B curve device
Conforms to EN/IEC 60898-1 and EN/IEC 60947-2. Part of the Schneider Electric Acti9 range.