The Circutor TP10 1250/5 (code M78037) is a single-phase split core current transformer that can be clamped around live conductors and flat busbars up to 80 x 120 mm without interrupting the power supply. It steps a 1250 A primary current down to a standard 5 A secondary output and is available across three accuracy classes, making it a practical choice for retrofitting current measurement into large distribution panels and switchboards.

Technical specifications:

  • Model: TP10 1250/5
  • Circutor code: M78037
  • EAN: 8433059401641
  • Transformer type: Split core
  • System: Single-phase
  • Measurement range: 1250/5 A
  • Flat strip (busbar) aperture: 80 x 120 mm
  • Inner diameter: 80 mm
  • Rated burden by accuracy class: Class 0.5 at 7 VA, Class 1 at 15 VA, Class 3 at 28 VA
  • Safety factor (SF): 10
  • Insulation voltage between terminals S1-S2: 3 kV
  • Maximum operating voltage: 0.72 kV AC
  • Nominal frequency: 50/60 Hz
  • Thermal short-circuit current (Ith): 60 In
  • Dynamic current (Idyn): 2.5 Ith
  • Dimensions (width x height x depth): 158 x 51 x 193.8 mm
  • Enclosure: Self-extinguishing plastic, class V0
  • Mounting: Wall-mounted or DIN rail (via accessory)
  • Weight: 0.55 kg
  • Thermal class: B (130 °C)
  • Protection class: IP 20
  • Working temperature: -5 to +40 °C
  • Storage temperature: -40 to +85 °C
  • Relative humidity: 15 to 85% (non-condensing)
  • Maximum installation altitude: 1000 m
  • Standards: UNE-EN 61869-1, UNE-EN 61869-2, UL 94

Features and benefits:

  • Split core design lets the transformer be fitted around live cables or busbars without cutting power, removing the need for planned outages during installation.
  • Wide 80 x 120 mm aperture accommodates the large flat busbars and high-current conductors common in main distribution boards and substations.
  • Three selectable accuracy classes (0.5, 1, and 3) allow the unit to be matched to energy billing, general metering, or protection relay applications.
  • Self-extinguishing V0 enclosure limits fire propagation risk inside electrical panels and switchgear cabinets.
  • Dual-frequency rating (50/60 Hz) makes the transformer suitable for use in both European and international power systems.

Applications:

  • Retrofitting current sensing into energised distribution boards and motor control centres without service interruption.
  • Energy metering and consumption monitoring on 1250 A single-phase circuits in industrial and commercial buildings.
  • Providing a 5 A secondary signal to power analysers, multifunction meters, and protection relays.
  • Current measurement on large flat busbar installations in switchboards where dismantling is impractical.

Also known as: Circutor TP10 1250/5, TP10 1250/5 M78037, split core current transformer 1250 A, Circutor M78037, split core CT 1250/5 A.

Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.

Klikněte zde pro požádání o cenovou nabídku

Důležité

Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.