Schneider A9F83106 Miniature Circuit Breaker (MCB), Acti9 iC60H, 1P 6A B curve 1

Doprava zdarma

Získejte dopravu zdarma při objednávce nad 300 €!

Původní cena €5,06 - Původní cena €5,06
Původní cena
€5,06
€5,06 - €5,06
Momentální cena €5,06

The Schneider Electric A9F83106 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 6 A with a B tripping curve. It delivers a breaking capacity of 10,000 A (Icn) at 230 V AC per EN/IEC 60898-1, and up to 15 kA (Icu) at 220-240 V AC per EN/IEC 60947-2, making it suitable for both residential and industrial distribution applications.

Technical specifications:

  • Commercial reference: A9F83106
  • Manufacturer: Schneider Electric
  • Series / range: Acti 9 iC60
  • Device short name: iC60H
  • Number of poles: 1P
  • Number of protected poles: 1
  • Rated current (In): 6 A
  • Tripping curve: B
  • Network type: AC / DC
  • Trip unit technology: Thermomagnetic
  • Breaking capacity (Icn): 10,000 A at 230 V AC 50/60 Hz per EN/IEC 60898-1
  • Breaking capacity (Icu): 15 kA at 220-240 V AC 50/60 Hz per EN/IEC 60947-2
  • Breaking capacity (Icu): 42 kA at 12-60 V AC 50/60 Hz per EN/IEC 60947-2
  • Breaking capacity (Icu): 15 kA at 100-133 V AC 50/60 Hz per EN/IEC 60947-2
  • Breaking capacity (Icu): 15 kA at 72 V DC per EN/IEC 60947-2
  • Breaking capacity (Icu): 20 kA at 12-60 V DC per EN/IEC 60947-2
  • Rated insulation voltage (Ui): 500 V AC 50/60 Hz
  • Rated impulse withstand voltage (Uimp): 6 kV
  • Overcurrent protection limit: 4 x In +/- 20%
  • Limitation class: 3 per EN/IEC 60898-1
  • Use category: Category A per EN/IEC 60947-2
  • Width: 18 mm
  • Height: 85 mm
  • Depth: 78.5 mm
  • Weight: 0.215 kg
  • IP rating: IP20 per IEC/EN 60529
  • Operating temperature: -35 to 70 °C
  • Storage temperature: -40 to 85 °C
  • Relative humidity: 95% at 55 °C
  • Mounting: DIN rail
  • Connection: Single terminal block (top or bottom), 1-25 mm² rigid / 1-16 mm² flexible
  • Tightening torque: 2 N.m (top or bottom)
  • Strip length: 14 mm
  • Mechanical endurance: 20,000 cycles
  • Electrical endurance: 10,000 cycles
  • Pollution degree: 3
  • Overvoltage category: IV
  • Standards: EN/IEC 60898-1, EN/IEC 60947-2

Features and benefits:

  • High breaking capacity of 10,000 A (Icn) at 230 V AC, providing robust short-circuit protection in demanding installations.
  • B tripping curve suited for loads with low inrush current, minimising nuisance tripping on resistive and cable protection circuits.
  • Compatible with both AC and DC networks, offering installation flexibility across diverse system types.
  • Comb busbar connection supported from top or bottom, simplifying wiring in multi-pole distribution boards.
  • Contact position indicator and trip indicator for fast visual diagnostics without opening the panel.
  • Suitable for isolation duty per EN/IEC 60898-1 and EN/IEC 60947-2, enabling safe maintenance procedures.

Applications:

  • Final distribution boards in residential and commercial buildings requiring reliable overcurrent and short-circuit protection.
  • Industrial control panels where AC and DC network compatibility and high breaking capacity are essential.
  • Cable protection in low-voltage switchgear and controlgear assemblies operating at 230 V AC or below.
  • DIN rail enclosures in light industrial and building automation installations with limited panel width (18 mm pitch).

Compliant with EN/IEC 60898-1 and EN/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.

Also known as: Schneider A9F83106, Schneider Electric A9F83106, Acti9 iC60H 1P 6A MCB, Schneider 6A B-curve circuit breaker.

Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.

Klikněte zde pro požádání o cenovou nabídku

Důležité

Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.