Přeskočit na obsah
Nemůžete najít, co hledáte? Kontaktujte nás!
Nemůžete najít, co hledáte? Kontaktujte nás!

Schneider A9F74103 Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 3A, C curve

Doprava zdarma

Získejte dopravu zdarma při objednávce nad 300 €!

Původní cena €5,39 - Původní cena €5,39
Původní cena
€5,39
€5,39 - €5,39
Momentální cena €5,39

The Schneider Electric A9F74103 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 3 A with a C tripping curve. It provides thermomagnetic overcurrent protection with a breaking capacity of 6,000 A Icn at 230 V AC, and is suitable for use on both AC and DC networks.

Technical specifications:

  • Commercial reference: A9F74103
  • Manufacturer: Schneider Electric
  • EAN:
  • Series / range: Acti 9 iC60
  • Product type: Miniature circuit breaker (MCB)
  • Number of poles: 1P
  • Rated current [In]: 3 A
  • Tripping curve: C
  • Network type: AC / DC
  • Protection technology: Thermomagnetic
  • Breaking capacity: 6,000 A Icn at 230 V AC (EN/IEC 60898-1); 50 kA Icu at 220-240 V AC (EN/IEC 60947-2)
  • Limitation class: 3 (EN/IEC 60898-1)
  • Rated insulation voltage [Ui]: 500 V AC 50/60 Hz
  • Rated impulse withstand voltage [Uimp]: 6 kV
  • Mounting: DIN rail
  • Dimensions (WxHxD): 18 x 85 x 78.5 mm
  • Weight: 0.215 kg
  • IP rating: IP20 (IEC/EN 60529)
  • Operating temperature: -35...70°C
  • Connection terminals: 1...25 mm² rigid / 1...16 mm² flexible
  • Tightening torque: 2 N.m
  • Mechanical durability: 20,000 cycles; electrical durability: 10,000 cycles
  • Standards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2
  • Quality marks: NF

Features and benefits:

  • Thermomagnetic protection for reliable overload and short-circuit tripping
  • High breaking capacity of 50 kA Icu at 220-240 V AC for demanding installations
  • Limitation class 3 reduces let-through energy and protects downstream equipment
  • Compatible with AC and DC networks for flexible installation across application types
  • Comb busbar compatible from upper or lower terminals for efficient panel wiring
  • Trip indicator provides clear local signaling of fault conditions

Applications:

  • Final distribution boards in residential and commercial buildings
  • Industrial control and automation panels requiring reliable overcurrent protection
  • DC network applications up to 72 V
  • Switchboards where high breaking capacity is required

Compliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.

Also known as: Schneider A9F74103, Schneider Electric A9F74103, iC60N 3A C curve MCB, Acti9 1P 3A miniature circuit breaker.

Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.

Klikněte zde pro požádání o cenovou nabídku

Důležité

Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.