Přeskočit na obsah
Nemůžete najít, co hledáte? Kontaktujte nás!
Nemůžete najít, co hledáte? Kontaktujte nás!

A9D20616 Proudový chránič s nadproudovou ochranou (RCBO), Acti9 DPN Vigi K, 1P+N, 16A, charakteristika C, 6000A, typ AC, 30mA

Doprava zdarma

Získejte dopravu zdarma při objednávce nad 300 €!

Původní cena €27,20 - Původní cena €27,20
Původní cena
€27,20
€27,20 - €27,20
Momentální cena €27,20

The Schneider Electric A9D20616 is an Acti 9 DPN Vigi K RCBO rated 16 A (1P+N, C curve) with 30 mA Type AC residual current sensitivity and a 6000 A breaking capacity at 220-240 V AC. It combines thermomagnetic overcurrent protection with integrated instantaneous earth fault protection for electrical power distribution applications.

Technical specifications:

  • Commercial reference: A9D20616
  • Manufacturer: Schneider Electric
  • EAN:
  • Series / range: Acti 9
  • Number of poles: 1P + N
  • Rated current [In]: 16 A
  • Tripping curve: C
  • Rated voltage: 220-240 V AC, 50 Hz
  • Breaking capacity [Icn]: 6000 A
  • Service breaking capacity [Ics]: 6000 A (100% Icn)
  • Residual current sensitivity: 30 mA, Type AC, instantaneous
  • Rated impulse withstand voltage [Uimp]: 4 kV
  • Limitation class: 3
  • IP rating: IP20 / IP40 (in modular enclosure)
  • Operating temperature: -5 to 40°C
  • Dimensions (W x H x D): 36 x 81 x 72 mm
  • Weight: 125 g
  • Mounting: DIN rail, clip-on
  • Connection terminals: phase 1-25 mm² rigid / 1-16 mm² flexible; neutral 1-16 mm² rigid / 1-10 mm² flexible
  • Mechanical and electrical durability: 20,000 cycles each
  • Certifications: VDE
  • Standard: EN/IEC 61009-2-1

Features and benefits:

  • Integrated RCD eliminates the need for a separate residual current device
  • Type AC sensitivity detects sinusoidal earth fault currents with instantaneous response
  • C curve thermomagnetic trip suits loads with moderate inrush currents
  • Contact position indicator with ON, OFF, and Fault trip local signaling for quick status checks
  • Left-side neutral positioning with 9 mm phase-to-neutral spacing supports modular board wiring

Applications:

  • Final distribution boards in residential and light commercial installations
  • Socket outlet circuit protection where earth fault protection is required
  • Single-phase circuits in modular consumer units and DIN rail enclosures
  • Space-constrained panels requiring combined overcurrent and residual current protection

Compliant with EN/IEC 61009-2-1. Part of the Schneider Electric Acti 9 range.

Also known as: Schneider A9D20616, Schneider Electric A9D20616, Acti9 DPN Vigi K RCBO 16A.

Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.

Klikněte zde pro požádání o cenovou nabídku

Důležité

Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.