Schneider Electric 18792 is a 2-pole Miniature Circuit Breaker (MCB) from the Acti 9 NG125L range, rated at 32A with a C tripping curve and a breaking capacity of 50kA at 380-415V AC. Designed for electrical power distribution, it combines thermomagnetic protection technology with high interrupting performance across AC and DC networks.
Technical specifications:
- Commercial reference: 18792
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 NG125
- Device short name: NG125L
- Number of poles: 2P
- Number of protected poles: 2
- Neutral conductor position: Left
- Rated current [In]: 32A at 40°C
- Tripping curve: C
- Network type: AC / DC
- Protection unit technology: Thermomagnetic
- Breaking capacity [Icu]: 100kA at 220-240V AC 50/60Hz; 50kA at 380-415V AC 50/60Hz; 40kA at 440V AC 50/60Hz; 15kA at 500V AC 50/60Hz; 36kA at <=250V DC (per EN/IEC 60947-2)
- Service breaking capacity [Ics]: 75kA (75%) at 220-240V AC; 37.5kA (75%) at 380-415V AC; 30kA (75%) at 440V AC; 11.25kA (75%) at 500V AC; 50kA (100%) at 250V DC
- Rated voltage [Ue]: 220-240V / 380-415V / 440V / 500V AC 50/60Hz; <=250V DC
- Rated insulation voltage [Ui]: 690V AC 50/60Hz
- Rated impulse withstand voltage [Uimp]: 8kV
- Overcurrent protection limit: 8 x In +/- 20%
- Usage category: Category A per IEC 60947-2
- Mounting: Click-on system, 35mm symmetrical DIN rail
- Handle mounting position: Vertical
- Busbar comb distribution block: Yes
- Width: 54mm
- Height: 103mm
- Depth: 81mm
- Weight: 0.48kg
- Connection terminals: Tunnel terminals 1.5-50mm² rigid; 1-35mm² flexible
- Wire strip length: 20mm
- Tightening torque: 3.5 N.m
- IP protection rating: IP20 (IEC 60529)
- IK protection rating: IK05 (EN/IEC 62262)
- Operating temperature: -30 to 70°C
- Storage temperature: -40 to 70°C
- Relative humidity: 95% at 55°C
- Operating altitude: 2000m
- Pollution degree: 3 (IEC 60947-2)
- Overvoltage category: IV
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Standard: EN/IEC 60947-2
Features and benefits:
- Exceptional breaking capacity of 100kA at 220-240V AC, suitable for demanding industrial power distribution applications
- Thermomagnetic protection technology provides reliable overload and short-circuit protection
- Compatible with both AC and DC networks, offering installation flexibility
- Integrated lockable handle for enhanced safety and access control
- Quick DIN rail snap-on mounting with busbar comb compatibility for efficient panel wiring
- Suitable for isolation per IEC 60947-2, doubling as a disconnection device
Applications:
- Final distribution boards in commercial and industrial buildings
- Main or sub-main circuit protection in industrial power distribution panels
- Protection of outgoing circuits in low-voltage switchgear assemblies
- DC network protection in renewable energy or battery-backed installations
- High-fault-level environments requiring elevated breaking capacity
Compliant with EN/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.
Also known as: Schneider 18792, Schneider Electric 18792, Acti9 NG125L 2P 32A MCB, Schneider NG125L C32 2-pole circuit breaker.
Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.
Důležité
Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.