Schneider A9F93116 Miniature Circuit Breaker (MCB), Acti9 iC60L, 1P B16A 15kA
Doprava zdarma
Získejte dopravu zdarma při objednávce nad 300 €!
Schneider Electric A9F93116 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60L range, rated at 16A with a B tripping characteristic. Designed for electrical distribution, it delivers a breaking capacity of 15kA at 230V AC and supports both AC and DC network types with thermomagnetic protection technology.
Technical specifications:
- Commercial reference: A9F93116
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Short device name: iC60L
- Number of poles: 1P
- Number of protected poles: 1
- Rated current [In]: 16A
- Tripping characteristic: B
- Network type: AC / DC
- Protection unit technology: Thermomagnetic
- Breaking capacity [Icn]: 15kA at 230V AC 50/60 Hz (EN/IEC 60898-1)
- Ultimate breaking capacity [Icu]: 70kA at 12-60V AC; 25kA at 220-240V AC; 25kA at 12-48V DC; 15kA at 72V DC (EN/IEC 60947-2)
- Service breaking capacity [Ics]: 7500A (50%) at 230V AC (EN/IEC 60898-1)
- Overcurrent protection limit: 4 x In +/- 20%
- Limitation class: 3 (EN/IEC 60898-1)
- Rated insulation voltage [Ui]: 500V AC 50/60 Hz
- Rated impulse withstand voltage [Uimp]: 6kV
- Usage category: Category A (EN/IEC 60947-2)
- Suitable for isolation: Yes
- Mounting: Fixed, DIN rail
- Busbar comb connection: Upper or lower
- Dimensions (WxHxD): 18 x 85 x 78.5 mm
- Weight: 0.215 kg
- Color: White
- IP protection rating: IP20 (IEC/EN 60529)
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 85 °C
- Relative humidity: 95% at 55 °C
- Pollution degree: 3
- Overvoltage category: IV
- Mechanical durability: 20,000 cycles
- Electrical durability: 10,000 cycles
- Connection: Single terminal block (upper or lower), 1-25 mm² solid / 1-16 mm² flexible
- Stripping length: 14 mm
- Tightening torque: 2 N.m
- Differential protection: None
- Standards: EN/IEC 60898-1, EN/IEC 60947-2
Features and benefits:
- High breaking capacity of 15kA at 230V AC, suitable for demanding distribution applications
- Supports both AC and DC networks with a wide voltage range
- Trip indicator for quick fault identification without opening the panel
- Wide operating temperature range (-35 to 70 °C) for use in harsh environments
- Compatible with comb busbar systems for efficient panel wiring
- Plastic-free, recycled cardboard packaging supporting Schneider Electric sustainability goals
Applications:
- Final distribution boards in residential and commercial buildings
- Protection of lighting and socket circuits in low-voltage installations
- Industrial control panels requiring AC and DC circuit protection
- Photovoltaic and DC distribution systems up to 72V DC
- Switchgear assemblies requiring high breaking capacity in compact form
Compliant with EN/IEC 60898-1 and EN/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.