The Schneider Electric A9F84110 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 10 A with a C tripping curve. Designed for electrical distribution applications, it offers a breaking capacity of 10 kA at 230 V AC per EN/IEC 60898-1 and is suitable for both AC and DC networks.
Technical specifications:
- Commercial reference: A9F84110
- Manufacturer: Schneider Electric
- Series / range: Acti 9 iC60
- Device short name: iC60H
- Number of poles: 1P
- Number of protected poles: 1
- Rated current [In]: 10 A
- Tripping curve: C
- Network type: AC / DC
- Protection unit technology: Thermomagnetic
- Breaking capacity [Icn]: 10,000 A at 230 V AC 50/60 Hz per EN/IEC 60898-1
- Breaking capacity [Icu]: 15 kA at 220-240 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity [Icu]: 42 kA at 12-60 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity [Icu]: 15 kA at 72 V DC per EN/IEC 60947-2
- Limitation class: 3 per EN/IEC 60898-1
- Rated insulation voltage [Ui]: 500 V AC 50/60 Hz per EN/IEC 60947-2
- Rated impulse withstand voltage [Uimp]: 6 kV per EN/IEC 60947-2
- Overcurrent protection limit: 8 x In +/- 20%
- Mounting: DIN rail
- Width: 18 mm (2 x 9 mm rows)
- Height: 85 mm
- Depth: 78.5 mm
- Weight: 0.215 kg
- IP protection rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 85 °C
- Relative humidity: 95% at 55 °C
- Connection: Single terminal block (top or bottom), 1-25 mm² solid / 1-16 mm² flexible
- Tightening torque: 2 N.m
- Mechanical durability: 20,000 cycles
- Electrical durability: 10,000 cycles
- Standards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2
- Color: White
Features and benefits:
- Thermomagnetic protection unit provides reliable overload and short-circuit protection in a compact 18 mm wide housing
- Compatible with both AC and DC networks, offering versatility across a wide range of applications
- High breaking capacity up to 42 kA (at 12-60 V AC) ensures safe disconnection under severe fault conditions
- Limitation class 3 reduces let-through energy, protecting downstream equipment from thermal and mechanical stress
- Trip indicator provides local signaling of fault trips for fast fault identification
- Suitable for isolation per EN/IEC 60898-1 and EN/IEC 60947-2, eliminating the need for a separate isolator
Applications:
- Final distribution boards in residential and commercial electrical installations
- Protection of branch circuits in industrial control panels
- DC distribution systems and battery-backed power circuits
- Busbar comb distribution systems requiring compact DIN rail MCBs
Compliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F84110, Schneider Electric A9F84110, iC60H C10 1P MCB, Acti9 10A C-curve miniature circuit breaker.
Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.
Důležité
Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.