The Schneider Electric 18861 is a 4-pole miniature circuit breaker (MCB) from the Acti9 NG125L series, rated at 32A with a D tripping curve and a breaking capacity of 50kA at 380-415V AC, designed for distribution applications in industrial and commercial installations.
Technical specifications:
- Commercial reference: 18861
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti9 NG125
- Product type: Miniature circuit breaker (MCB)
- Device application: Distribution
- Number of poles: 4P
- Number of protected poles: 4
- Neutral position: Left
- Rated current [In]: 32A at 40°C
- Tripping curve: D
- Trip unit technology: Thermal-magnetic
- Network type: AC / DC
- Breaking capacity [Icu]: 100kA at 220-240V AC - 50kA at 380-415V AC - 40kA at 440V AC - 15kA at 500V AC - 36kA at 500V DC (EN/IEC 60947-2)
- Rated service breaking capacity [Ics]: 75kA at 220-240V AC - 37.5kA at 380-415V AC (EN/IEC 60947-2)
- Rated insulation voltage [Ui]: 690V AC
- Rated impulse withstand voltage [Uimp]: 8kV
- Magnetic tripping limit: 12 x In +/- 20%
- Utilisation category: Category A (IEC 60947-2)
- Mounting: Clip-on, 35mm symmetrical DIN rail, vertical
- Width: 108mm - Height: 103mm - Depth: 81mm
- Weight: 0.96kg
- Connection terminals: Tunnel type, 1.5-50mm² rigid / 1-35mm² flexible
- Tightening torque: 3.5 N.m
- IP protection rating: IP20 (IEC 60529)
- IK protection: IK05 (EN/IEC 62262)
- Operating temperature: -30 to 70°C
- Storage temperature: -40 to 70°C
- Operating altitude: 2000m
- Pollution degree: 3 (IEC 60947-2)
- Standard: EN/IEC 60947-2
- Mechanical durability: 20000 cycles
- Electrical durability: 10000 cycles
Features and benefits:
- High breaking capacity of 50kA at 380-415V AC ensures reliable protection in demanding distribution networks
- D curve thermal-magnetic trip unit suitable for loads with high inrush currents
- Suitability for isolation confirmed per IEC 60947-2, enabling safe maintenance procedures
- Integrated padlocking provision for lockout/tagout safety compliance
- Compatible with comb busbars and distribution blocks for flexible panel wiring
- Wide operating temperature range (-30 to 70°C) supports use in harsh environments
Applications:
- Industrial distribution boards and motor control centers requiring high breaking capacity
- Commercial and industrial panels with loads exhibiting high inrush currents (D curve)
- Power distribution in buildings with elevated short-circuit levels
- Main and sub-distribution panels in factories, warehouses, and infrastructure projects
Compliant with EN/IEC 60947-2. Part of the Schneider Electric Acti9 NG125 range.
Also known as: Schneider 18861, Schneider Electric 18861, NG125L 4P D32A, Acti9 NG125L MCB 32A.
Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.
Důležité
Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.