Schneider LADS2 Time Delay Auxiliary Contact Block, TeSys Deca, 1NO+1NC, On-Dela
Doprava zdarma
Získejte dopravu zdarma při objednávce nad 300 €!
The Schneider Electric LADS2 is a time delay auxiliary contact block from the TeSys Deca range, designed for front-mounting on compatible contactors and starters. It provides 1 NO + 1 NC contact configuration with on-delay timer functionality, offering an adjustable time delay range of 1 to 30 seconds for sequenced control applications.
Technical specifications:
- Commercial reference: LADS2
- Manufacturer: Schneider Electric
- Series / range: TeSys Deca
- Product type: Time delay auxiliary contact block
- Contact configuration: 1 NO + 1 NC
- Timer type: On-delay (delay on energisation)
- Time delay range: 1...30 s
- Rated operational voltage [Ue]: 690 V AC, 25...400 Hz
- Rated operational current [Ie]: 6 A at 120 V AC-15 / 1.04 A at 690 V AC-15 / 0.55 A at 125 V DC-13 / 0.1 A at 600 V DC-13
- Rated insulation voltage [Ui]: 690 V (IEC 60947-5-1) / 600 V (UL / CSA)
- Conventional thermal current [Ith]: 10 A at 60 °C
- Making capacity (Irms): 140 A at 690 V AC / 250 A at 690 V DC
- Mechanical endurance: 5 million operating cycles
- Minimum switching current: 5 mA
- Minimum switching voltage: 17 V
- Insulation resistance: > 10 MOhm
- Mounting location: Front
- Connection: Screw terminals, 1...2.5 mm², flexible or solid conductors
- Tightening torque: 1.7 N.m
- Dimensions (HxWxD): 48 x 44 x 61 mm
- Colour: Dark grey
- IP protection rating: IP20 (IEC 60529)
- Operating temperature: -40...70 °C
- Storage temperature: -60...80 °C
- Maximum operating altitude: 3000 m
- Standards: EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, EN 50012
- Certifications: IECEE CB, UL, CSA, CCC, EAC, UKCA
- Warranty: 18 months
Features and benefits:
- Adjustable on-delay timing from 1 to 30 seconds enables flexible sequencing of motor starting operations
- Compatible with TeSys Deca CAD, TeSys Deca LC1D, TeSys F LC1F, and TeSys F CR1F product families
- Non-overlap time of 1.5 ms between NC and NO contacts prevents simultaneous contact closure
- Wide operating temperature range of -40...70 °C suits demanding industrial environments
- PVC-free construction and recyclable cardboard packaging support sustainability requirements
- Multiple international certifications (UL, CSA, CCC, EAC, UKCA) facilitate global project deployment
Applications:
- Star-delta motor starters requiring timed transition between starting and running contactors
- Industrial motor control panels where sequenced energisation of control circuits is required
- Automation switchboards using TeSys D or TeSys F contactors needing auxiliary timing functions
- Machine control applications requiring a defined on-delay before auxiliary circuit activation
Compliant with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, and GB/T 14048.5. Part of the Schneider Electric TeSys Deca range.
Also known as: Schneider LADS2, Schneider Electric LADS2, TeSys D time delay auxiliary contact block, on-delay timer contact block.
Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.
Důležité
Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.