The Schneider Electric A9F83116 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 16A with a B tripping curve. It provides thermomagnetic overcurrent protection for AC and DC networks, with a breaking capacity of 10,000A at 230V AC per IEC/EN 60898-1 and up to 15kA at 220-240V AC per IEC/EN 60947-2.

Technical specifications:

  • Commercial reference: A9F83116
  • Manufacturer: Schneider Electric
  • EAN:
  • Series / range: Acti 9 iC60
  • Product type: Miniature Circuit Breaker (MCB)
  • Short designation: iC60H
  • Number of poles: 1P
  • Number of protected poles: 1
  • Rated current: 16A
  • Tripping curve: B
  • Network type: AC / DC
  • Trip unit technology: Thermomagnetic
  • Breaking capacity: 10,000A Icn at 230V AC per EN/IEC 60898-1; 15kA Icu at 220-240V AC per EN/IEC 60947-2; 42kA Icu at 12-60V AC per EN/IEC 60947-2; 15kA Icu at 72V DC per EN/IEC 60947-2
  • Limitation class: 3 per EN/IEC 60898-1
  • Rated insulation voltage: 500V AC at 50/60 Hz
  • Rated impulse withstand voltage: 6kV
  • Overcurrent limit: 4 x In +/- 20%
  • Network frequency: 50/60 Hz
  • Mounting: DIN rail
  • Width: 18mm (2 x 9mm rows)
  • Height: 85mm
  • Depth: 78.5mm
  • Weight: 0.215kg
  • IP rating: IP20 per IEC/EN 60529
  • Operating temperature: -35 to 70°C
  • Storage temperature: -40 to 85°C
  • Relative humidity: 95% at 55°C
  • Connection: Single terminal block 1-25mm² rigid / 1-16mm² flexible; strip length 14mm; tightening torque 2 N.m
  • Mechanical durability: 20,000 cycles
  • Electrical durability: 10,000 cycles
  • Standards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2
  • Warranty: 18 months

Features and benefits:

  • High breaking capacity of 10kA at 230V AC (IEC/EN 60898-1) and 15kA at 220-240V AC (IEC/EN 60947-2) for robust protection in demanding installations
  • Suitable for both AC and DC networks, providing flexibility across different electrical systems
  • B tripping curve for protection of sensitive circuits and loads with low inrush currents
  • Compact 18mm width with comb busbar compatibility (upper or lower) for space-efficient panel design
  • Trip indication and contact position indicator for quick status identification without opening the panel
  • Limitation class 3 for reduced let-through energy, minimising thermal and mechanical stress on downstream equipment

Applications:

  • Final distribution boards in residential and light commercial buildings
  • Protection of lighting circuits and sensitive electronic equipment requiring B-curve characteristics
  • Low-voltage electrical panels in industrial and commercial installations
  • DC circuit protection in photovoltaic and battery systems (up to 72V DC)
  • Electrical energy distribution systems requiring IEC/EN 60947-2 compliance

Compliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.