Přeskočit na obsah
Nemůžete najít, co hledáte? Kontaktujte nás!
Nemůžete najít, co hledáte? Kontaktujte nás!

Circutor M78012 TP6 Split Core Current Transformer 100/5A, 30x30mm

podle CIRCUTOR

Doprava zdarma

Získejte dopravu zdarma při objednávce nad 300 €!

Původní cena €54,96 - Původní cena €54,96
Původní cena
€54,96
€54,96 - €54,96
Momentální cena €54,96

The Circutor TP6 100/5 (code M78012) is a single-phase split-core current transformer rated 100/5 A with a 30 × 30 mm busbar and cable opening. The split-core construction allows the unit to be fitted around an energised conductor or busbar without interrupting the circuit, making it well suited to retrofit metering work. The secondary output is a standard 5 A signal compatible with energy meters and panel instruments.

Technical specifications:

  • Model: TP6 100/5
  • Circutor code: M78012
  • EAN: 8433059401184
  • Measurement range: 100/5 A
  • System: Single-phase
  • Transformer type: Split core
  • Busbar / flat strip opening: 30 × 30 mm
  • Inner diameter: 30 mm
  • Rated power (Class 3): 1 VA
  • Safety factor (SF): 10
  • Insulation voltage between terminals S1-S2: 3 kV
  • Operating voltage: 0.72 kV~ max.
  • Nominal frequency: 50/60 Hz
  • Dynamic current (Idyn): 2.5 Ith
  • Thermal short-circuit current (Ith): 60 In
  • Overall dimensions (W × H × D): 100 × 51 × 101.8 mm
  • Enclosure: Plastic, V0 self-extinguishing
  • Mounting: Wall-mounted or DIN rail (accessory required)
  • Weight: 0.55 kg
  • Protection class: IP 20
  • Thermal class: Class B (max. +130 °C)
  • Working temperature: -5 to +40 °C
  • Storage temperature: -40 to +85 °C
  • Relative humidity: 15-85% (non-condensing)
  • Maximum installation altitude: 1000 m
  • Standards: UNE-EN 61869-1, UNE-EN 61869-2, UL 94

Features and benefits:

  • Split-core design permits installation on live cables and busbars, removing the need for a planned power interruption.
  • Accepts flat conductors and busbars up to 30 × 30 mm without dismantling existing wiring or switchgear.
  • V0 self-extinguishing plastic enclosure limits fire propagation inside closed panels and distribution boards.
  • Sealable terminals and cable fastening accessories are supplied with the unit, covering standard installation requirements without additional procurement.
  • Rated for working temperatures from -5 to +40 °C and storage down to -40 °C, suitable for indoor panels and unheated enclosures.

Applications:

  • Retrofitting energy monitoring or billing metering to live low-voltage distribution boards where a power outage is impractical.
  • Current measurement in single-phase cable or busbar systems with conductors up to 30 × 30 mm.
  • Supplying a 5 A secondary signal to panel instruments, energy analysers, or power meters.
  • Metering installations requiring sealable, tamper-evident measurement terminals.

Also known as: Circutor TP6 100/5, TP6 100/5 M78012, Circutor M78012, split core current transformer 100/5 A, split core CT 30 × 30 mm.

Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.

Klikněte zde pro požádání o cenovou nabídku

Důležité

Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.