Circutor R13864 Computer SMART III 14 Power Factor Regulator 14-Step RS-485

podle CIRCUTOR

Doprava zdarma

Získejte dopravu zdarma při objednávce nad 300 €!

Původní cena €265,98 - Původní cena €265,98
Původní cena
€265,98
€265,98 - €265,98
Momentální cena €265,98

The Circutor Computer SMART III 14 (code R13864) is a three-phase automatic power factor regulator that manages reactive energy compensation across 14 contactor-switched steps. It accepts an AC supply of 100...400 V at 50...60 Hz and communicates via RS-485 using the Modbus RTU protocol, making it a capable choice for both new installations and regulator replacements in industrial compensation panels.

Technical specifications:

  • Model: Computer SMART III 14
  • Circutor code: R13864
  • EAN: 8433059227494
  • Type: Three-phase power factor regulator
  • Number of regulation steps: 14
  • Switching unit: Contactor
  • AC power supply: 100...400 V AC, 50...60 Hz
  • Power consumption: 14...18 VA
  • Voltage measurement range: 20...300 V Ph-N / 35...520 V Ph-Ph
  • Nominal voltage: 230 V Ph-N / 400 V Ph-Ph
  • Minimum measurement voltage: 20 V Ph-N / 35 V Ph-Ph
  • Input current: .../5 A or .../1 A
  • Phase current measuring range: 1...120% of nominal
  • Minimum current measurement: 50 mA
  • Serial communication: RS-485, Modbus RTU
  • Digital relay outputs: 16 total (14 step outputs, 1 fan, 1 alarm relay)
  • Relay output ratings: 1 A, 1 kV max open-contact voltage, 2500 VA max switching capacity
  • Relay electrical life: 30 x 10^3 cycles; mechanical life: 5 x 10^6 cycles
  • Digital transistor outputs: 2 x NPN, 50 mA, 24 V DC
  • Digital inputs: 2, optoisolated, potential-free contact
  • Leakage current measurement range: 0.01...1.5 A
  • Active power measurement accuracy: 0.5% +/- 1 digit
  • Reactive power measurement accuracy: 1% +/- 2 digits, Class 1
  • Active energy accuracy: 0.5% +/- 2 digits
  • Reactive energy accuracy: Class 1
  • Phase current accuracy: 0.5% +/- 1 digit
  • Installation category: CAT III 300 V
  • Protection class: IP 51 (front panel) / IP 31 (unmounted)
  • Dimensions (W x H x D): 144 x 144 x 71 mm
  • Mounting: Panel
  • Weight: 0.619 kg
  • Operating temperature: -10...+55 °C
  • Storage temperature: -20...+70 °C
  • Relative humidity: 5...95% (non-condensing)
  • Display: LCD custom COG
  • Interface: Capacitive keyboard (5 keys), 4 LED indicators
  • Maximum installation altitude: 2000 m
  • Standards: IEC 61010, IEC 61000-6-2, IEC 61000-6-4, IEC 61557-12

Features and benefits:

  • Supports measurement with either one or three current transformers, allowing the regulator to mirror the utility meter reading precisely and handle installations where phase currents are significantly unbalanced.
  • Residual leakage current monitoring is available when used with compatible WG-series current transformers, adding an extra layer of safety supervision within the compensation panel.
  • RS-485 Modbus RTU communication enables integration with SCADA systems, energy management platforms, or building automation networks for centralised monitoring.
  • Up to four programmable cos phi target values can be set to match different tariff time periods, reducing manual intervention when consumption patterns change throughout the day.
  • The wide AC supply range of 100...400 V and voltage measurement span up to 520 V Ph-Ph make the unit suitable for diverse grid conditions without requiring additional matching transformers.

Applications:

  • Automatic reactive energy compensation in industrial plants, manufacturing facilities, and large commercial buildings to reduce reactive energy penalties.
  • Retrofitting or upgrading the controller in existing capacitor banks where a drop-in regulator replacement is required.
  • Installations with pronounced phase current imbalances where three-transformer measurement delivers greater compensation accuracy than a single-CT setup.
  • Medium voltage compensation systems that require a regulator capable of operating across a broad voltage measurement range.

Also known as: Circutor Computer SMART III 14, Computer SMART III 14 R13864, R13864 power factor controller, Circutor reactive energy regulator, three-phase power factor regulator 14-step.

Když je vyprodáno, můžete si stále předobjednat žádostí o cenovou nabídku níže.

Klikněte zde pro požádání o cenovou nabídku

Důležité

Zobrazené obrázky slouží pouze pro ilustraci a nemusí přesně odpovídat produktu.