A9F84220 Schneider Electric Miniaturní jistič (MCB), Acti9 iC60H 2P C20A 10kA

Doprava zdarma

Získejte dopravu zdarma při objednávce nad 300 €!

Vyprodáno
Původní cena €13,41 - Původní cena €13,41
Původní cena
€13,41
€13,41 - €13,41
Momentální cena €13,41

The Schneider Electric A9F84220 is a 2-pole, 20 A Miniature Circuit Breaker (MCB) from the Acti 9 iC60H series, featuring a C tripping curve and thermomagnetic protection technology. Suitable for both AC and DC networks, it delivers a 10 kA breaking capacity at 400 V AC per IEC 60898-1 and up to 30 kA at 220-240 V AC per IEC 60947-2, making it well suited to demanding distribution applications.

Technical specifications:

  • Commercial reference: A9F84220
  • Manufacturer: Schneider Electric
  • EAN:
  • Series / range: Acti 9 iC60
  • Number of poles: 2P (2 protected poles)
  • Rated current: 20 A
  • Tripping curve: C
  • Network type: AC / DC
  • Protection technology: Thermomagnetic
  • Breaking capacity (Icn): 10 kA at 400 V AC per IEC/EN 60898-1
  • Breaking capacity (Icu): 15 kA at 380-415 V AC; 30 kA at 220-240 V AC; 42 kA at 12-133 V AC; 15 kA at DC up to 125 V per IEC/EN 60947-2
  • Limitation class: 3 per IEC/EN 60898-1
  • Rated insulation voltage (Ui): 500 V AC
  • Rated impulse withstand voltage (Uimp): 6 kV
  • Overcurrent trip threshold: 8 x In +/- 20%
  • Mounting: DIN rail (fixed)
  • Dimensions (W x H x D): 36 x 85 x 78.5 mm
  • Weight: 0.25 kg
  • IP rating: IP20 per IEC/EN 60529
  • Operating temperature: -35 to 70°C
  • Storage temperature: -40 to 85°C
  • Connection: 1-25 mm² rigid / 1-16 mm² flexible; tightening torque 2 N.m
  • Mechanical endurance: 20,000 cycles
  • Electrical endurance: 10,000 cycles
  • Pollution degree: 3; overvoltage category IV

Features and benefits:

  • Thermomagnetic protection guards against both overloads and short circuits on AC and DC networks
  • Limitation class 3 enables fast current limiting, reducing thermal and mechanical stress on the installation
  • Compatible with comb busbars on upper or lower terminals for flexible panel wiring
  • Built-in contact position indicator and trip indicator for immediate visual status confirmation
  • Wide operating temperature range of -35 to 70°C for use in harsh or outdoor enclosure environments

Applications:

  • Final distribution boards in residential and commercial buildings
  • Industrial control panels requiring reliable overcurrent protection
  • DC distribution systems up to 125 V DC
  • Low-voltage switchgear and controlgear assemblies

Compliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.

Also known as: Schneider A9F84220, Schneider Electric A9F84220, iC60H 2P C20A MCB, Acti9 miniature circuit breaker 20A 2 pole.