The Siemens 5SU1336-6FP10 is a SENTRON 3-pole RCBO (residual current circuit breaker with overcurrent protection) rated 10 A on a B tripping characteristic with 30 mA Type A residual current detection. It combines earth-leakage protection and overload/short-circuit protection in a single 3-module device for 400 V AC three-phase final circuits.

Technical specifications:

  • Order number (MLFB): 5SU1336-6FP10
  • Manufacturer: Siemens
  • Product line: SENTRON
  • Product type: RCBO (instantaneous design)
  • Number of poles: 3 (3P, all three poles protected)
  • Tripping characteristic: B
  • Rated current (In): 10 A
  • Tripping fault current (IΔn): 30 mA
  • Residual current type: A (detects AC and pulsating DC fault currents)
  • Short-circuit breaking capacity:
    • 6 kA per EN 60898
    • 6 kA per IEC 60947-2
    • 6 kA Icn per EN 61009-1
    • 4.5 kA IΔm rated residual switching capacity per IEC 61009-1
  • Energy limitation class: 3
  • Supply voltage: 400 V AC, 50 Hz
  • Test voltage (min): 340 V
  • Insulation voltage (Ui): 500 V
  • Surge voltage resistance: 4 kV
  • Surge current resistance (8/20 µs): 0.25 kA
  • Overvoltage category: 3
  • Pollution degree: 3
  • Derated operational current: 9.6 A @ 40 °C; 9.4 A @ 45 °C; 9.1 A @ 50 °C; 8.9 A @ 55 °C; 8.6 A @ 60 °C; 8.2 A @ 70 °C
  • Power loss: max 2.1 W
  • Mechanical service life: 10,000 operating cycles
  • Touch protection: Yes
  • Halogen-free: No
  • IP protection: IP20 with connected conductors when installed in distribution board
  • Conductor range: 1-35 mm² (solid, stranded, and finely stranded with end-sleeve)
  • Tightening torque: 2 N·m
  • Power supply position: top or bottom
  • Height: 85 mm; Width: 54 mm (3 modules); Depth: 72 mm; installation depth 70 mm
  • Mounting position: any
  • Ambient temperature: -25 °C to +40 °C (operation), -40 °C to +70 °C (storage)
  • Humidity: max 95%
  • Weight: 339 g
  • Standards: IEC/EN 61009-1, IEC/EN 60947-2, EN 60898
  • EAN/GTIN: 4001869577838

Features and benefits:

  • All-in-one earth-leakage and overcurrent protection for three-phase circuits in 3-module width - fewer devices per final circuit
  • Type A residual current detection - reliably trips on pulsating DC fault currents from rectifiers, switching power supplies and electronic loads
  • B tripping characteristic - suited to resistive loads and long cable runs with low fault-loop impedance
  • 30 mA personal-protection threshold per IEC 60364-4-41
  • Instantaneous (non-delayed) design for fast disconnection on earth faults
  • Touch protection to IP20 with connected conductors for safe handling in live panels
  • Bidirectional power supply position - mount with top or bottom infeed
  • Any mounting position for flexible enclosure layout

Applications:

  • Three-phase 400 V AC final circuits requiring combined earth-leakage and overcurrent protection
  • Circuits feeding electronics, IT loads or rectifier-fed equipment requiring Type A detection
  • Distribution boards where a B characteristic is required for resistive loads or long cable runs
  • Replacement of separate MCB + RCD pairs to save panel space

Also known as: Siemens 5SU1336-6FP10, SENTRON RCBO 3P Type A B10A 30mA, Siemens 5SU1 series RCBO 10A 30mA 6kA, 5SU13 residual current circuit breaker with overcurrent.

When sold out, you can still preorder by requesting a quote below.

Click here to request a quote

Important

The images shown are for illustration purposes only and may not be an exact
representation of the product.