{"product_id":"siemens-5su1324-7fa06-sentron-rcbo-2p-type-a-c-6a-30ma-10ka","title":"Siemens 5SU1324-7FA06 SENTRON RCBO 2P Type A C 6A 30mA 10kA","description":"\u003cp\u003eThe Siemens 5SU1324-7FA06 is a SENTRON 2-pole RCBO (residual current circuit breaker with overcurrent protection) rated 6 A on a C tripping characteristic with 30 mA Type A residual current detection. It combines earth-leakage and overload\/short-circuit protection in a single 1-module device, switching both phase and neutral simultaneously.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOrder number (MLFB): 5SU1324-7FA06\u003c\/li\u003e\n\u003cli\u003eManufacturer: Siemens\u003c\/li\u003e\n\u003cli\u003eProduct line: SENTRON\u003c\/li\u003e\n\u003cli\u003eProduct type: RCBO (instantaneous design)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2 (both poles protected; 1P+N functionality with neutral switching)\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n\u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n\u003cli\u003eTripping fault current (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eResidual current type: A (detects AC and pulsating DC fault currents)\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity:\n  \u003cul\u003e\n  \u003cli\u003e10 kA per EN 60898\u003c\/li\u003e\n  \u003cli\u003e35 kA per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003e10 kA Icn per EN 61009-1\u003c\/li\u003e\n  \u003cli\u003e10 kA Im residual switching capacity per IEC 61009-1\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnergy limitation class: 3\u003c\/li\u003e\n\u003cli\u003eSupply voltage: 230\/240 V AC, 50 Hz\u003c\/li\u003e\n\u003cli\u003eTest voltage (min): 195 V AC\u003c\/li\u003e\n\u003cli\u003eInsulation voltage (Ui): 264 V\u003c\/li\u003e\n\u003cli\u003eSurge voltage resistance: 4 kV\u003c\/li\u003e\n\u003cli\u003eSurge current resistance (8\/20 µs): 1 kA\u003c\/li\u003e\n\u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eDerated operational current: 5.7 A @ 40 °C; 5.4 A @ 50 °C; 4.86 A @ 65 °C; 4.62 A @ 70 °C\u003c\/li\u003e\n\u003cli\u003ePower loss: max 3.7 W\u003c\/li\u003e\n\u003cli\u003eMechanical service life: 10,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eTouch protection: Yes\u003c\/li\u003e\n\u003cli\u003eNeutral conductor switching: Yes\u003c\/li\u003e\n\u003cli\u003eHalogen-free: Yes\u003c\/li\u003e\n\u003cli\u003eSilicon-free: Yes\u003c\/li\u003e\n\u003cli\u003eIP protection: IP20 with connected conductors when installed in distribution board\u003c\/li\u003e\n\u003cli\u003eConductor range: 0.75-35 mm² (solid\/stranded), 0.75-25 mm² (finely stranded with end-sleeve)\u003c\/li\u003e\n\u003cli\u003eTightening torque: 2.5-3 N·m\u003c\/li\u003e\n\u003cli\u003ePower supply position: top or bottom\u003c\/li\u003e\n\u003cli\u003eHeight: 90 mm; Width: 54 mm (3 modules)\u003c\/li\u003e\n\u003cli\u003eStandards: IEC\/EN 61009-1, IEC\/EN 60947-2\u003c\/li\u003e\n\u003cli\u003eEAN\/GTIN: 4001869305882\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll-in-one earth-leakage + overcurrent protection in 3-module width - fewer devices per final circuit\u003c\/li\u003e\n\u003cli\u003eType A residual current detection - reliably trips on pulsating DC faults from rectifiers, switching power supplies and inverter loads\u003c\/li\u003e\n\u003cli\u003e10 kA EN 60898 \/ 35 kA IEC 60947-2 breaking capacity - usable in both residential and industrial installations\u003c\/li\u003e\n\u003cli\u003e30 mA personal-protection threshold per IEC 60364-4-41 - mandatory additional protection for socket-outlet circuits in many jurisdictions\u003c\/li\u003e\n\u003cli\u003eHalogen- and silicon-free housing - clean room and food\/pharma compatible\u003c\/li\u003e\n\u003cli\u003eBidirectional power supply position - mount with top or bottom infeed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFinal socket-outlet circuits in residential and commercial installations (additional 30 mA personal protection per IEC 60364-4-41)\u003c\/li\u003e\n\u003cli\u003eWet-area circuits (bathrooms, kitchens, outdoor outlets) requiring earth-leakage + overcurrent protection\u003c\/li\u003e\n\u003cli\u003eFinal circuits feeding electronics, IT loads or inverter-driven equipment requiring Type A detection\u003c\/li\u003e\n\u003cli\u003eReplacement of separate MCB + RCD pairs to save panel space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: Siemens 5SU1324-7FA06, SENTRON RCBO 2P Type A C 6A 30mA, Siemens 5SU1 series RCBO 6A 30mA, 5SU13 residual current circuit breaker with overcurrent.\u003c\/p\u003e","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":57867415486728,"sku":"SMN5SU1324-7FA06","price":48.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/siemens-5su1324-7fa06-sentron-rcbo-2p-type-a-c-6a-30ma-10ka-3955464.png?v=1779394056","url":"https:\/\/gabbyelectric.com\/products\/siemens-5su1324-7fa06-sentron-rcbo-2p-type-a-c-6a-30ma-10ka","provider":"Gabby Electric","version":"1.0","type":"link"}