Siemens 3VA5215-5EC31-0AA0 MCCB 3P 150A 35kA TM230 Frame 250
Free Shipping
Get free shipping on orders exceeding €300!
The Siemens 3VA5215-5EC31-0AA0 is a 3-pole SENTRON 3VA5 moulded case circuit breaker (MCCB) in the UL Frame 250 size, rated In 150 A with a TM230 thermal-magnetic trip unit for line protection (LI). It provides fixed overload protection and adjustable short-circuit protection in power distribution boards, control panels and machine installations, with switching capacity class M: 35 kA at 480 V to UL 489 and 55 kA at 415 V to IEC 60947.
Technical specifications:
- MLFB: 3VA5215-5EC31-0AA0
- Manufacturer: Siemens
- Product brand: SENTRON
- Series: 3VA5, UL Frame 250
- Product type: Moulded case circuit breaker (MCCB), system protection
- Number of poles: 3
- Trip unit: TM230 thermal-magnetic, LI protection function (FTAM)
- Rated current In: 150 A
- Overload protection Ir: 150 A, permanently set
- Short-circuit protection Ii: 5 - 10 x In, adjustable (750 - 1,500 A)
- Switching capacity class: M
- Icu and Ics (IEC 60947): 85 kA at 240 V, 55 kA at 415 V, 7 kA at 690 V
- Icm (IEC 60947): 187 kA at 240 V, 121 kA at 415 V, 11.9 kA at 690 V
- Breaking capacity (UL 489): 85 kA at 240 V, 35 kA at 480 V, 18 kA at 600 V
- Rated operating voltage: 690 V AC, 750 V DC
- Rated insulation voltage: 800 V
- Operational current vs ambient temperature: 150 A at 40 °C, 141 A at 50 °C, 132 A at 60 °C, 123 A at 70 °C
- Power loss: 30 W max, 9.7 W per pole at rated current
- Mechanical service life: 20,000 operating cycles
- Electrical endurance: 8,000 cycles at 380/415 V AC-1, 4,000 cycles at 690 V AC-1
- Degree of protection: IP40 on the front
- Ambient temperature: -25 °C to 70 °C (operation), -40 °C to 80 °C (storage)
- Dimensions (H x W x D): 185 x 105 x 83 mm
- Net weight: 2.048 kg
- Main connections: supplied without connection terminals
- Auxiliary contacts: none fitted
- Optional extension: motor operator
- EAN: 4042948854280
Features and benefits:
- Adjustable instantaneous trip from 5 to 10 x In for selectivity with downstream devices
- Dual IEC 60947 and UL 489 ratings for equipment built for both European and North American markets
- Ics equal to Icu (55 kA at 415 V), so full breaking performance is kept after a fault
- Can be fitted with a motor operator for remote switching
Applications:
- Incoming and outgoing feeder protection in low voltage distribution boards
- Line and cable protection in industrial control panels and machinery
- Panels exported to UL markets that need a UL 489 breaker
- Replacement for existing 3VA5 Frame 250 breakers
Rated to IEC 60947 and UL 489. Part of the Siemens SENTRON 3VA moulded case circuit breaker range.
Also known as: Siemens 3VA5 150A 3 pole, SENTRON 3VA MCCB 150 A, 3VA5 Frame 250 TM230, Siemens 3VA5215-5EC31-0AA0 circuit breaker
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.