{"product_id":"schneider-electric-c10f44v040-nsx100f-circuit-breaker-36ka-415vac-4p-4-2-40a","title":"Schneider Electric C10F44V040 NSX100F Circuit Breaker 36kA\/415VAC 4P 4.2 40A","description":"\u003cp\u003eThe Schneider Electric C10F44V040 is a 4-pole differential circuit breaker from the ComPacT NSX new generation range (NSX100F), rated 40 A at 40 °C with a performance level of 36 kA at 415 V AC. It is designed for AC power distribution applications and is fitted with the Micrologic 4.2 electronic protection unit providing overload, short-time short-circuit, instantaneous, and earth-leakage protection (LSoIR function).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRated current [In]: 40 A at 40 °C\u003c\/li\u003e\n\u003cli\u003eRated voltage [Ue]: 440 V AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePoles: 4P; protected-pole configurations: 4d, 3d+N\/2, or 3d; neutral conductor position: left\u003c\/li\u003e\n\u003cli\u003eUltimate breaking capacity [Icu] per IEC 60947-2: 85 kA at 220\/240 V AC; 36 kA at 380\/415 V AC; 35 kA at 440 V AC; 25 kA at 500 V AC; 8 kA at 660\/690 V AC\u003c\/li\u003e\n\u003cli\u003eService breaking capacity [Ics] per IEC 60947-2: 85 kA at 220\/240 V AC; 36 kA at 380\/415 V AC; 12 kA at 500 V AC; 4 kA at 660\/690 V AC\u003c\/li\u003e\n\u003cli\u003eProtection unit: Micrologic 4.2 electronic — L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), R (earth-leakage \/ differential)\u003c\/li\u003e\n\u003cli\u003eEarth-leakage sensitivity [IΔn]: Adjustable — 30 mA, 100 mA, 300 mA, 500 mA, 1 A, 3 A, or 5 A; Class A; earth-leakage can be switched off via IΔn reversing switch\u003c\/li\u003e\n\u003cli\u003eLong-time pick-up [Ir]: Adjustable across 9 settings, 18–40 A; long-time delay 400 s at 1.5×Ir, 16 s at 6×Ir, 11 s at 7.2×Ir\u003c\/li\u003e\n\u003cli\u003eShort-time pick-up [Isd]: Adjustable 1.5–10×Ir; fixed at 600 A; short-time delay integrated\u003c\/li\u003e\n\u003cli\u003eThermal memory: 20 minutes before and after tripping\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage [Ui]: 500 V AC; rated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n\u003cli\u003eMechanical endurance: 50,000 cycles; electrical endurance: 50,000 cycles at 440 V In\/2; 30,000 cycles at 440 V In; 10,000 cycles at 690 V In\u003c\/li\u003e\n\u003cli\u003eMounting: Fixed; front upper and lower connections; back-plate mounting bracket; handle mountable horizontally, vertically, or flat on the back\u003c\/li\u003e\n\u003cli\u003eUtilisation category: Category A; suitable for isolation per EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":58023186333960,"sku":"SCHC10F44V040","price":409.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/13443-schneider-electric-mini-enclosure-for-modular-device-mureva-enclosure-1x8-modules-earth-and-neutral-terminal-blocks-6040146_b8207ec3-95e2-4402-9204-06598a8b8c45.png?v=1781473326","url":"https:\/\/gabbyelectric.com\/products\/schneider-electric-c10f44v040-nsx100f-circuit-breaker-36ka-415vac-4p-4-2-40a","provider":"Gabby Electric","version":"1.0","type":"link"}