Schneider LADR2 TeSys Time Delay Auxiliary Contact Block
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric LADR2 is a TeSys D time delay auxiliary contact block featuring a 1 NO + 1 NC arrangement for front-mounting on TeSys D and TeSys F contactors. It delivers off-delay timing adjustable from 1 to 30 seconds, rated at 690 V AC with a conventional thermal current of 10 A at 60°C.
Technical specifications:
- Commercial reference: LADR2
- Manufacturer: Schneider Electric
- EAN:
- Series / range: TeSys D / TeSys Deca
- Product type: Time delay auxiliary contact block
- Contact arrangement: 1 NO + 1 NC
- Timer type: Off-delay
- Time delay range: 1...30 s
- Rated operational voltage [ue]: 690 V AC, 25...400 Hz
- Rated current [ie]: 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
- Rated insulation voltage [ui]: 690 V per IEC 60947-5-1; 600 V per UL / CSA
- Conventional thermal current [ith]: 10 A at 60°C
- Rated making capacity (Irms): 140 A at 690 V AC; 250 A at 690 V DC
- Mechanical endurance: 5 million cycles
- Minimum switching current: 5 mA
- Minimum switching voltage: 17 V
- Connection type: Screw terminals, 1...2.5 mm² flexible or rigid, with or without ferrule
- Tightening torque: 1.7 N.m
- Mounting location: Front
- Dimensions (WxHxD): 44 x 48 x 61 mm
- IP protection rating: IP20 per IEC 60529
- Operating temperature: -40...70°C
- Storage temperature: -60...80°C
- Operating altitude: up to 3000 m
- Color: Dark grey
- Certifications: IECEE CB Scheme, UL, CSA, CCC, EAC, UKCA
Features and benefits:
- Off-delay timer adjustable from 1 to 30 seconds enables controlled shutdown sequencing in motor circuits.
- Compatible with TeSys Deca CAD, LC1D, TeSys F LC1F, and CR1F for broad integration across the TeSys contactor range.
- Non-overlap time of 1.5 ms on both opening and closing prevents contact bridging between NC and NO states.
- Insulation resistance greater than 10 MOhm and GG fuse protection at 10 A ensure reliable circuit integrity.
- Operating range of -40 to 70°C and IP20 protection support demanding industrial environments.
Applications:
- Motor control panels requiring timed shutdown sequencing after contactor de-energisation.
- Industrial automation switchgear where auxiliary off-delay timing is needed between circuit events.
- HVAC and refrigeration control systems in compliance with IEC 60335-2-40 Annex JJ.
- Machine control cabinets built around TeSys D or TeSys F contactors.
Compliant with EN/IEC 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and EN 50012. Part of the Schneider Electric TeSys D / TeSys Deca range.
Also known as: Schneider LADR2, Schneider Electric LADR2, TeSys off-delay auxiliary contact block, time delay auxiliary contact 1NO 1NC.