Schneider LADN116 Auxiliary contact block
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric LADN116 is an auxiliary contact block from the TeSys Deca range, designed for front mounting on TeSys D and TeSys Deca contactors. It provides 1NO+1NC instantaneous pole contact composition with a rated operational voltage of 690 V AC and is rated for 6 A at 120 V AC-15, making it suitable for control circuit signalling and interlocking applications.
Technical specifications:
- Commercial reference: LADN116
- Manufacturer: Schneider Electric
- EAN:
- Series / range: TeSys Deca
- Product type: Auxiliary contact block
- Pole contact composition: 1 NO + 1 NC
- Contacts operation: Instantaneous
- Mounting location: Front
- Rated operational voltage [Ue]: 690 V AC, 25...400 Hz
- Rated operational current [Ie]: 6 A at 120 V AC-15 / 1.04 A at 690 V AC-15 / 0.55 A at 125 V DC-13 / 0.1 A at 600 V DC-13
- Rated insulation voltage [Ui]: 690 V (IEC 60947-5-1) / 600 V (UL, CSA)
- Conventional free air thermal current [Ith]: 10 A at 60 °C
- Rated making capacity (Irms): 140 A AC / 250 A DC (IEC 60947-5-1)
- Minimum switching current: 5 mA
- Minimum switching voltage: 17 V
- Non-overlap time: 1.5 ms (energisation and de-energisation)
- Insulation resistance: greater than 10 MOhm
- Connection type: Lugs-ring terminals (external diameter: 8 mm)
- Tightening torque: 1.7 N.m (M3.5)
- Protection type: GG fuse 10 A
- Mechanical durability: 30 Mcycles
- Width: 26 mm / Height: 48 mm / Depth: 42 mm
- Weight: 33 g
- Colour: Dark grey
- IP protection rating: IP20 (IEC 60529)
- Operating temperature: -5...60 °C
- Storage temperature: -60...80 °C
- Operating altitude: 3000 m
- Standards: EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1, CSA C22.2 No 60947-5-1
- Certifications: CB Scheme, UL, CSA, CCC, EAC, UKCA
Features and benefits:
- 1NO+1NC instantaneous contacts enable simultaneous normally-open and normally-closed signalling from a single block
- Front mounting design allows easy addition to TeSys D and TeSys Deca contactors without replacing the base unit
- 1.5 ms non-overlap time between NC and NO contacts prevents false signals during switching transitions
- Wide compatibility across TeSys D CAD, LC1D, TeSys F LC1F, CR1F, and TeSys Deca ranges
- Rated for 30 million mechanical cycles, ensuring long service life in high-cycle applications
- Lugs-ring terminal connection with M3.5 screws provides secure, vibration-resistant wiring
Applications:
- Motor starter control circuits requiring auxiliary signalling and status feedback
- Industrial automation panels using TeSys D or TeSys Deca contactors for interlocking logic
- HVAC control systems where contactor position feedback is needed for building management integration
- Machine safety circuits requiring NC contact monitoring of contactor state
- PLC input modules receiving run/stop status signals from motor control centres
Compliant with EN/IEC 60947-5-1, EN 50012, UL 60947-5-1, and CSA C22.2 No 60947-5-1. Part of the Schneider Electric TeSys Deca range.
Also known as: Schneider LADN116, Schneider Electric LADN116, TeSys auxiliary contact block, contactor auxiliary contact 1NO+1NC.