{"product_id":"hager-mcn116e-miniature-circuit-breaker-1p-c16a-6ka-1-module","title":"Hager MCN116E Miniature Circuit Breaker 1P C16A 6kA 1 Module","description":"\u003cp\u003eThe Hager MCN116E is a single-pole miniature circuit breaker rated 16 A with a type C tripping characteristic and 6 kA breaking capacity to IEC 60898-1. It is one module wide and clips onto 35 mm DIN rail in consumer units and distribution boards.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eReference: MCN116E\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Hager\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of modules: 1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity Icn at 230 V AC (IEC 60898-1): 6 kA\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity at 400 V (EN 60947-2): 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated voltage (Ue): 230-400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4000 V\u003c\/li\u003e\n  \u003cli\u003eEnergy limiting class: 3\u003c\/li\u003e\n  \u003cli\u003ePollution degree (IEC 664): 2\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eTotal power loss at In: 2.40 W\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section: 1-35 mm2 solid, 1-25 mm2 flexible\u003c\/li\u003e\n  \u003cli\u003eTerminal tightening torque: 2.80 N.m\u003c\/li\u003e\n  \u003cli\u003eLower terminal type: biconnect\u003c\/li\u003e\n  \u003cli\u003eUpper terminal type: Screw terminal\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm DIN rail, 360 deg mounting position possible\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 C to 70 C\u003c\/li\u003e\n  \u003cli\u003eTropicalisation: Suitable for all climates\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant: Yes\u003c\/li\u003e\n  \u003cli\u003eRated current at 30 C: 16 A\u003c\/li\u003e\n  \u003cli\u003eRated current at 40 C: 15.3 A\u003c\/li\u003e\n  \u003cli\u003eRated current at 60 C: 13.3 A\u003c\/li\u003e\n  \u003cli\u003eDimensions (HxWxD): 83 x 17.50 x 70 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n  \u003cli\u003eType C characteristic for inductive loads with moderate inrush current\u003c\/li\u003e\n  \u003cli\u003e6 kA breaking capacity to IEC 60898-1 and EN 60947-2\u003c\/li\u003e\n  \u003cli\u003ebiconnect lower terminal for fast busbar connection\u003c\/li\u003e\n  \u003cli\u003eEnergy limiting class 3 for reduced let-through energy\u003c\/li\u003e\n  \u003cli\u003e360 degree mounting position and same-height terminals for tidy assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n  \u003cli\u003eOverload and short-circuit protection of final circuits\u003c\/li\u003e\n  \u003cli\u003eMotor, transformer and discharge-lighting circuits with inrush current\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial distribution boards\u003c\/li\u003e\n  \u003cli\u003eExtension of existing Hager consumer units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComplies with IEC 60898-1 and EN 60947-2. RoHS compliant.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Hager MCN116E, MCB 1P C16A 6kA.\u003c\/p\u003e","brand":"HAGER","offers":[{"title":"Default Title","offer_id":58552529486088,"sku":"HGRMCN116E","price":4.76,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/HGRMCN116E.png?v=1787773962","url":"https:\/\/gabbyelectric.com\/products\/hager-mcn116e-miniature-circuit-breaker-1p-c16a-6ka-1-module","provider":"Gabby Electric","version":"1.0","type":"link"}