Schneider A9R41440 Acti9 iID RCCB 4P 40 A 30mA Type AC
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9R41440 is a 4-pole residual current circuit breaker (RCCB) from the Acti 9 iID range, rated at 40 A with 30 mA sensitivity for AC-type earth fault protection. Designed as an outgoing device in AC distribution systems, it delivers instantaneous tripping to protect people and installations from residual fault currents.
Technical specifications:
- Commercial reference: A9R41440
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iID
- Product type: Residual current circuit breaker (RCCB)
- Number of poles: 4P
- Neutral conductor position: Left
- Rated current [In]: 40 A
- Network type: AC
- Residual current sensitivity: 30 mA
- Tripping delay: Instantaneous
- Residual current class: Type AC
- Rated voltage [Ue]: 380...415 V AC 50/60 Hz
- Rated insulation voltage [Ui]: 500 V AC 50/60 Hz
- Rated impulse withstand voltage [Uimp]: 6 kV
- Rated conditional short-circuit current: 10 kA
- Rated making/breaking capacity: Idm/Im 1500 A
- Surge current withstand: 250 A (8/20 µs)
- Mounting: Snap-on, DIN rail
- Dimensions (WxHxD): 72 x 91 x 73.5 mm
- Weight: 0.37 kg
- IP rating: IP20 / IP40 in modular enclosure (IEC 60529)
- Operating temperature: -5...60 °C
- Connection: Single terminal block upper or lower, 1...35 mm² rigid / 1...25 mm² flexible
- Strip length: 14 mm
- Tightening torque: 3.5 N.m
- Mechanical durability: 20,000 cycles
- Pollution degree: 3
- Standards: EN/IEC 61008-1, EN/IEC 61008-2-1
Features and benefits:
- Instantaneous, voltage-independent tripping technology ensures reliable earth fault protection
- Snap-on DIN rail mounting allows fast, tool-free installation
- Built-in contact position indicator provides quick visual status check
- Compatible locking device option prevents unauthorized switching
- Wide conductor acceptance range (1...35 mm² rigid) suits diverse wiring configurations
Applications:
- Final distribution boards in residential and commercial buildings
- Three-phase and neutral AC circuit protection in modular enclosures
- Outgoing feeder protection in industrial control panels
- Installations requiring Type AC residual current protection per IEC 61008
Compliant with EN/IEC 61008-1 and EN/IEC 61008-2-1. Part of the Schneider Electric Acti 9 iID range.