{"product_id":"a9n18363-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120n-2p-c125a-10ka","title":"Schneider A9N18363 Miniature Circuit Breaker (MCB), Acti9 C120N, 2P C125A 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18363 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 C120N range, rated at 125 A with a C tripping curve. Designed for electrical distribution applications, it delivers a breaking capacity of 10 kA at 230-400 V AC and is suitable for use on AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18363\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current: 125 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10 kA at 230-400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC; 10 kA at 380-415 V AC; 6 kA at 440 V AC; 10 kA at \u0026lt;= 250 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 220-240 V \/ 380-415 V \/ 440 V AC 50\/60 Hz; \u0026lt;= 250 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5-10 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetric DIN rail, snap-on\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.41 kg\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel terminals, 1-50 mm² solid \/ 1.5-35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2, EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 5,000 cycles (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve characteristic provides reliable protection for resistive and slightly inductive loads with high inrush currents\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per IEC 60947-2, enabling safe maintenance procedures\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible for streamlined panel wiring\u003c\/li\u003e\n  \u003cli\u003eHandle sealable in ON or OFF position with cable diameter 0.7 mm for tamper prevention\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25 to 70°C) supports installation in demanding environments\u003c\/li\u003e\n  \u003cli\u003eDC-rated up to 250 V, suitable for photovoltaic and battery-backed distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain or sub-main circuit protection in commercial and industrial distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in large switchgear panels and busbar systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial power distribution where high breaking capacity and isolation are required\u003c\/li\u003e\n  \u003cli\u003eDC distribution circuits in photovoltaic or energy storage installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2 and EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18363, Schneider Electric A9N18363, Acti9 C120N 2P 125A MCB, Schneider 125A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53453077315848,"sku":"SCHA9N18363","price":69.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18363-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120n-2p-c125a-10ka-2915196.jpg?v=1773354561","url":"https:\/\/gabbyelectric.com\/products\/a9n18363-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120n-2p-c125a-10ka","provider":"Gabby Electric","version":"1.0","type":"link"}