Schneider A9K01320 Acti9 K60N MCB 3P 20 A B Curve 6kA DIN Rail
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9K01320 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated at 20 A with a B tripping curve and 6 kA breaking capacity at 400 V AC. Designed for electrical power distribution, it combines thermomagnetic protection technology with compact DIN rail mounting for use in distribution boards and final circuits.
Technical specifications:
- Commercial reference: A9K01320
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 K60
- Product type: Miniature circuit breaker (MCB)
- Number of poles: 3P
- Number of protected poles: 3
- Rated current [In]: 20 A
- Tripping curve: B
- Network type: AC
- Protection technology: Thermomagnetic
- Breaking capacity [Icn]: 6000 A at 400 V AC 50/60 Hz per EN/IEC 60898-1
- Service breaking capacity [Ics]: 6000 A (100%) at 400 V AC 50/60 Hz per EN/IEC 60898-1
- Overcurrent protection range: 3...5 x In
- Rated insulation voltage [Ui]: 440 V AC 50/60 Hz
- Rated impulse withstand voltage [Uimp]: 4 kV
- Limitation class: 3 per EN/IEC 60898-1
- Network frequency: 50/60 Hz
- Mounting: DIN rail
- Width: 54 mm (6 x 9 mm modules)
- Height: 81 mm
- Depth: 70 mm
- Weight: 0.36 kg
- IP rating: IP20 per IEC 60529
- Operating temperature: -25...70 °C
- Storage temperature: -40...70 °C
- Connection: Tunnel terminals, 0.5...35 mm² rigid / 0.5...25 mm² flexible (top and bottom)
- Tightening torque: 3.5 N.m
- Strip length: 14 mm
- Standards: EN/IEC 60898-1
- Certifications: OVE, VDE
- Mechanical / electrical durability: 20,000 cycles
- Color: White
Features and benefits:
- B curve thermomagnetic protection suitable for resistive and lightly inductive loads with low inrush currents
- 6 kA breaking capacity (Icn = Ics at 100%) ensures reliable fault clearance without derating
- Compact 54 mm width (6 modules) optimises space in distribution boards
- Wide conductor range (0.5...35 mm² rigid) accommodates diverse wiring requirements
- Wide operating temperature range of -25...70 °C suits demanding installation environments
- Halogen-free product with 56% minimum recycled plastic content supporting sustainability goals
Applications:
- Final circuit protection in residential and commercial electrical distribution boards
- Protection of resistive loads such as lighting circuits and heating elements
- Industrial control panels requiring compact 3-pole overcurrent protection
- Branch circuit protection in DIN rail enclosures
- Low-inrush load protection in building electrical installations
Compliant with EN/IEC 60898-1, Usage Category A per IEC 60947-2, and certified by OVE and VDE. Part of the Schneider Electric Acti 9 K60 range.
Also known as: Schneider A9K01320, Schneider Electric A9K01320, Acti9 K60N 3P 20A B curve MCB, Schneider 3-pole 20A miniature circuit breaker.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.