Schneider A9F83120 Miniature Circuit Breaker (MCB), Acti9 iC60H, 1P, 20A, B curv
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F83120 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 20A with a B tripping curve. Designed for AC and DC network distribution, it delivers a breaking capacity of 10,000A at 230V AC per EN/IEC 60898-1 and up to 15kA at 220-240V AC per EN/IEC 60947-2.
Technical specifications:
- Commercial reference: A9F83120
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Number of poles: 1P
- Number of protected poles: 1
- Rated current [In]: 20A
- Network type: AC / DC
- Trip unit technology: Thermomagnetic
- Tripping curve: B
- Breaking capacity [Icn]: 10,000A at 230V AC 50/60 Hz per EN/IEC 60898-1
- Ultimate breaking capacity [Icu]: 15kA at 220-240V AC; 42kA at 12-60V AC; 30kA at 100-133V AC; 15kA at up to 72V DC; 20kA at 12-60V DC per EN/IEC 60947-2
- Service breaking capacity [Ics]: 7,500A (75%) at 230V AC per EN/IEC 60898-1
- Limitation class: 3 per EN/IEC 60898-1
- Rated insulation voltage [Ui]: 500V AC 50/60 Hz per EN/IEC 60947-2
- Rated impulse withstand voltage [Uimp]: 6kV per EN/IEC 60947-2
- Overcurrent protection limit: 4 x In +/- 20%
- Mounting: Fixed, DIN rail
- Width: 18mm (2 x 9mm rows)
- Height: 85mm
- Depth: 78.5mm
- Weight: 0.215kg
- IP rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70°C
- Storage temperature: -40 to 85°C
- Relative humidity: 95% at 55°C
- Pollution degree: 3 per EN/IEC 60947-2
- Overvoltage category: IV
- Connection: Single terminal block (top or bottom), 1-25mm² rigid / 1-16mm² flexible
- Strip length: 14mm
- Tightening torque: 2 N.m
- Mechanical durability: 20,000 cycles
- Electrical durability: 10,000 cycles
- Standards: IEC 60947-2, EN 60947-2, EN 60898-1, IEC 60898-1
- Warranty: 18 months
Features and benefits:
- High breaking capacity of 10kA at 230V AC makes it suitable for demanding distribution applications
- B tripping curve provides sensitive overcurrent protection, ideal for long cable runs and resistive loads
- Compatible with comb busbar distribution blocks from top or bottom, simplifying panel wiring
- Contact position indicator and trip indicator enable fast local fault diagnosis
- Suitable for isolation per EN/IEC 60898-1 and EN/IEC 60947-2
- Tropicalization class 2 per IEC 60068-1 ensures reliable operation in humid environments
Applications:
- Final distribution boards in residential and commercial electrical installations
- Protection of lighting circuits and resistive loads requiring sensitive B-curve tripping
- Industrial control panels and power distribution in AC and DC systems
- Protection of long cable runs where low inrush currents are expected
Compliant with IEC 60947-2, EN 60947-2, EN 60898-1, and IEC 60898-1. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F83120, Schneider Electric A9F83120, iC60H 20A B curve MCB, Acti9 1P 20A miniature circuit breaker.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.