Schneider A9F74316 Acti9 iC60N MCB 3P 16 A C Curve 10kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F74316 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 16 A with a C tripping curve. Designed for electrical power distribution, it provides reliable overcurrent protection with a breaking capacity of 10 kA at 380-415 V AC, suitable for both AC and DC network types.
Technical specifications:
- Commercial reference: A9F74316
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Number of poles: 3P
- Number of protected poles: 3
- Rated current: 16 A
- Tripping curve: C
- Network type: AC / DC
- Protection technology: Thermomagnetic
- Breaking capacity (Icn): 6000 A at 400 V AC 50/60 Hz per EN/IEC 60898-1
- Breaking capacity (Icu): 10 kA at 380-415 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity (Icu): 20 kA at 220-240 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity (Icu): 10 kA at up to 180 V DC per EN/IEC 60947-2
- Limitation class: 3 per EN/IEC 60898-1
- Rated insulation voltage (Ui): 500 V AC 50/60 Hz per EN/IEC 60947-2
- Rated impulse withstand voltage (Uimp): 6 kV per EN/IEC 60947-2
- Overvoltage category: IV
- Dimensions (WxHxD): 54 x 85 x 78.5 mm
- Weight: 0.375 kg
- IP rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 85 °C
- Relative humidity: 95 % at 55 °C
- Mounting: DIN rail
- Connection: Single terminal block (top or bottom), 1-25 mm² rigid / 1-16 mm² flexible
- Tightening torque: 2 N.m
- Strip length: 14 mm
- Mechanical endurance: 20000 cycles
- Electrical endurance: 10000 cycles
- Standards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2
Features and benefits:
- C tripping curve provides reliable protection for loads with moderate inrush currents
- Compatible with both AC and DC networks for versatile installation
- Comb busbar distribution block connection available from top or bottom terminals
- Contact position indicator and trip indicator for fast fault diagnosis
- Wide operating temperature range of -35 to 70 °C for demanding environments
- Suitable for isolation per EN/IEC 60898-1 and EN/IEC 60947-2
Applications:
- Final distribution boards in commercial and industrial buildings
- Protection of branch circuits in electrical panels and switchboards
- Industrial control panels requiring AC and DC circuit protection
- Power distribution systems with comb busbar arrangements
Compliant with EN/IEC 60898-1 and EN/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F74316, Schneider Electric A9F74316, Schneider iC60N 3P 16A MCB, Acti9 miniature circuit breaker C curve.