Schneider A9Z05225 Acti9 ID K RCCB 2P 25 A 30mA Type AC

Free Shipping

Get free shipping on orders exceeding €300!

Original price $20.66 - Original price $20.66
Original price
$20.66
$20.66 - $20.66
Current price $20.66

The Schneider Electric A9Z05225 is a 2-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 ID K range, rated at 25 A with a 30 mA sensitivity for AC-type earth fault protection. Designed for final distribution, it provides instantaneous tripping to protect personnel and equipment against residual currents in AC networks operating at 220-240 V AC 50 Hz.

Technical specifications:

  • Commercial reference: A9Z05225
  • Manufacturer: Schneider Electric
  • EAN:
  • Series / range: Acti 9 ID K
  • Product type: RCCB (Residual Current Circuit Breaker)
  • Number of poles: 2P
  • Neutral position: Left
  • Rated current (In): 25 A
  • Network type: AC
  • Residual current sensitivity: 30 mA
  • Tripping delay: Instantaneous
  • RCD class: Type AC
  • Rated voltage (Ue): 220-240 V AC 50 Hz
  • Network frequency: 50/60 Hz
  • Rated making and breaking capacity: Idm 500 A, Im 500 A
  • Rated conditional short-circuit current: GL63: Inc 4.5 kA / K60: Inc 6 kA
  • Rated insulation voltage (Ui): 440 V AC 50 Hz
  • Rated impulse withstand voltage (Uimp): 4 kV
  • Mounting: DIN rail, click-on system, 9 mm pitch - 4 rows
  • Dimensions (WxHxD): 36 x 81 x 68 mm
  • Weight: 0.18 kg
  • IP rating: IP20 (IEC 60529) / IP40 in modular enclosure (IEC 60529)
  • Operating temperature: -5 to 40 °C
  • Storage temperature: -30 to 70 °C
  • Connection: Double connection upper or lower, 1-35 mm² rigid / 1-25 mm² flexible
  • Tightening torque: 3.5 N.m
  • Strip length: 14 mm
  • Mechanical endurance: 5000 cycles
  • Electrical endurance: AC-1: 2000 cycles
  • Quality mark: VDE
  • Standards: EN/IEC 61008-1, EN/IEC 61008-2-1
  • Warranty: 18 months

Features and benefits:

  • Instantaneous tripping at 30 mA sensitivity for fast earth fault disconnection
  • Type AC residual current detection covers sinusoidal fault currents
  • Independent tripping technology ensures operation independent of mains voltage
  • Click-on DIN rail mounting for fast, tool-free installation in modular enclosures
  • Double-terminal connection accepts both rigid and flexible conductors up to 35 mm²
  • VDE-certified and compliant with EN/IEC 61008-1 for verified performance

Applications:

  • Residential final distribution boards requiring personal protection against earth faults
  • Commercial building electrical panels with AC supply networks
  • Modular DIN rail enclosures in offices, retail, and light industrial installations
  • Outgoing circuits requiring 30 mA RCD protection per electrical installation standards

Compliant with EN/IEC 61008-1 and EN/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.