{"product_id":"a9y82740-schneider-electric-add-on-residual-current-devices-vigi-ic40-3p-n-40a-30ma-ac-type","title":"Schneider A9Y82740 Acti9 iC40 Vigi Add-On RCD 3P+N 40A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9Y82740 is an \u003cstrong\u003eActi9 Vigi iC40 add-on residual current device (RCD) block\u003c\/strong\u003e, configured as \u003cstrong\u003e3P + N, 40 A rated current, 30 mA sensitivity, Type AC\u003c\/strong\u003e. It clips onto a compatible Acti9 iC40 circuit breaker to add earth-leakage protection downstream, with the neutral pole positioned on the left and instantaneous tripping. The unit is voltage-independent (functions without auxiliary supply) and is rated 400 V AC at 50\/60 Hz, with a 440 V AC rated insulation voltage and 4 kV impulse withstand. A local fault indicator signals the trip status on the front face.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eActi9 iC40 Vigi block, 3P + N, 40 A, 30 mA Type AC residual current protection\u003c\/li\u003e\n\u003cli\u003eInstantaneous tripping, voltage-independent (works without auxiliary supply)\u003c\/li\u003e\n\u003cli\u003eRated operational voltage Ue 400 V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage Ui 440 V AC; impulse withstand Uimp 4 kV\u003c\/li\u003e\n\u003cli\u003eLocal fault-indication window on the front\u003c\/li\u003e\n\u003cli\u003eClips onto compatible Acti9 iC40 MCB; electrical link to MCB by screws\u003c\/li\u003e\n\u003cli\u003eWhite housing, 4 modules wide (9 mm pitch), DIN-rail mounted\u003c\/li\u003e\n\u003cli\u003eMechanical endurance 20,000 cycles, electrical endurance 10,000 cycles\u003c\/li\u003e\n\u003cli\u003eLower tunnel terminals: 1-16 mm² rigid \/ 1-10 mm² flexible, 14 mm strip length, 2 N·m torque\u003c\/li\u003e\n\u003cli\u003eCompliant with EN\/IEC 61009-2-1; CE marked; IMQ and OVE quality labels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRange: Acti9 (PowerLogic catalog family)\u003c\/li\u003e\n\u003cli\u003eProduct: Acti9 Vigi iC40 add-on Vigi block\u003c\/li\u003e\n\u003cli\u003eCompatibility: Acti9 iC40\u003c\/li\u003e\n\u003cli\u003ePoles: 3P + N (neutral on the left)\u003c\/li\u003e\n\u003cli\u003eRated current In: 40 A\u003c\/li\u003e\n\u003cli\u003eEarth-leakage sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eEarth-leakage class: Type AC\u003c\/li\u003e\n\u003cli\u003eTripping delay: Instantaneous\u003c\/li\u003e\n\u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eUe \/ Ui \/ Uimp: 400 V AC \/ 440 V AC \/ 4 kV\u003c\/li\u003e\n\u003cli\u003eTripping technology: Voltage independent\u003c\/li\u003e\n\u003cli\u003eDevice position in system: Downstream (output)\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm (4 modules at 9 mm pitch)\u003c\/li\u003e\n\u003cli\u003eHeight: 99.5 mm; Depth: 74 mm\u003c\/li\u003e\n\u003cli\u003eColor: White\u003c\/li\u003e\n\u003cli\u003eMounting: Clip-on, DIN rail\u003c\/li\u003e\n\u003cli\u003eConnection to MCB: By screws\u003c\/li\u003e\n\u003cli\u003eTerminals: Lower tunnel, 1-16 mm² rigid \/ 1-10 mm² flexible\u003c\/li\u003e\n\u003cli\u003eStripping length: 14 mm; Tightening torque: 2 N·m\u003c\/li\u003e\n\u003cli\u003eIngress protection: IP20 (IP40 in modular enclosure) per IEC 60529\u003c\/li\u003e\n\u003cli\u003ePollution degree: 3\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 95 % at 55 °C\u003c\/li\u003e\n\u003cli\u003eOperating altitude: 2,000 m\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -5 to +60 °C; Storage: -40 to +85 °C\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 20,000 cycles; Electrical durability: 10,000 cycles\u003c\/li\u003e\n\u003cli\u003eStandards: EN\/IEC 61009-2-1; Certifications: CE; Quality labels: IMQ, OVE\u003c\/li\u003e\n\u003cli\u003eCountry of origin: Spain (ES); Warranty: 18 months\u003c\/li\u003e\n\u003cli\u003eEU RoHS: Compliant with exemption; REACh: Contains SVHC above threshold\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eDesigned for final distribution boards in residential, commercial and light-industrial installations where downstream earth-leakage protection must be added to an existing Acti9 iC40 miniature circuit breaker. Suitable for three-phase plus neutral circuits up to 40 A on AC networks, providing protection against sinusoidal AC residual currents in line with EN\/IEC 61009-2-1. Typical uses include lighting and power sub-distribution, small motor circuits, HVAC feeders and general purpose three-phase loads. Type AC is not suitable for circuits containing DC components or pulsating DC fault currents - use Type A or higher where electronic loads (variable speed drives, inverters, switched-mode power supplies) are present.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53453077217544,"sku":"SCHA9Y82740","price":103.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9y82740-schneider-electric-add-on-residual-current-devices-vigi-ic40-3pn-40a-30ma-ac-type-2685400.jpg?v=1773354561","url":"https:\/\/gabbyelectric.com\/en-us\/products\/a9y82740-schneider-electric-add-on-residual-current-devices-vigi-ic40-3p-n-40a-30ma-ac-type","provider":"Gabby Electric","version":"1.0","type":"link"}