{"product_id":"a9f83106-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-1p-6a-b-curve-10000a-15ka","title":"Schneider A9F83106 Miniature Circuit Breaker (MCB), Acti9 iC60H, 1P 6A B curve 1","description":"\u003cp\u003eThe Schneider Electric A9F83106 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 6 A with a B tripping curve. It delivers a breaking capacity of 10,000 A (Icn) at 230 V AC per EN\/IEC 60898-1, and up to 15 kA (Icu) at 220-240 V AC per EN\/IEC 60947-2, making it suitable for both residential and industrial distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F83106\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60H\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 1P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 1\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10,000 A at 230 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 15 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 42 kA at 12-60 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 15 kA at 100-133 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 15 kA at 72 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 12-60 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWidth: 18 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.215 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m (top or bottom)\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 10,000 A (Icn) at 230 V AC, providing robust short-circuit protection in demanding installations.\u003c\/li\u003e\n  \u003cli\u003eB tripping curve suited for loads with low inrush current, minimising nuisance tripping on resistive and cable protection circuits.\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering installation flexibility across diverse system types.\u003c\/li\u003e\n  \u003cli\u003eComb busbar connection supported from top or bottom, simplifying wiring in multi-pole distribution boards.\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for fast visual diagnostics without opening the panel.\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation duty per EN\/IEC 60898-1 and EN\/IEC 60947-2, enabling safe maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings requiring reliable overcurrent and short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels where AC and DC network compatibility and high breaking capacity are essential.\u003c\/li\u003e\n  \u003cli\u003eCable protection in low-voltage switchgear and controlgear assemblies operating at 230 V AC or below.\u003c\/li\u003e\n  \u003cli\u003eDIN rail enclosures in light industrial and building automation installations with limited panel width (18 mm pitch).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F83106, Schneider Electric A9F83106, Acti9 iC60H 1P 6A MCB, Schneider 6A B-curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53477171855624,"sku":"SCHA9F83106","price":5.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/schneider-a9f83106-miniature-circuit-breaker-mcb-acti9-ic60h-1p-6a-b-curve-1-3188952.jpg?v=1779036894","url":"https:\/\/gabbyelectric.com\/en-us\/products\/a9f83106-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-1p-6a-b-curve-10000a-15ka","provider":"Gabby Electric","version":"1.0","type":"link"}