Schneider A9F73302 Acti9 iC60N MCB 3P 2 A B Curve 10kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F73302 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 2 A with a B tripping curve for electrical energy distribution on AC and DC networks. Thermomagnetic protection technology guards against both overload and short-circuit conditions. Breaking capacity is 6000 A Icn at 400 V AC per IEC 60898-1, rising to 50 kA Icu at 380-415 V AC per IEC 60947-2.
Technical specifications:
- Commercial reference: A9F73302
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Number of poles: 3P, 3 protected poles
- Rated current: 2 A
- Tripping curve: B
- Network type: AC / DC
- Protection technology: Thermomagnetic
- Breaking capacity (Icn): 6000 A at 400 V AC 50/60 Hz per EN/IEC 60898-1
- Breaking capacity (Icu): 50 kA at 220-240 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity (Icu): 50 kA at 380-415 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity (Icu): 25 kA at 440 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity (Icu): 10 kA at up to 180 V DC per EN/IEC 60947-2
- Service breaking capacity (Ics): 50 kA 100% at 380-415 V AC per EN/IEC 60947-2
- Overcurrent protection limit: 4 x In +/- 20%
- Limitation class: 3 per EN/IEC 60898-1
- Usage category: Category A per EN/IEC 60947-2
- Rated insulation voltage (Ui): 500 V AC 50/60 Hz per EN/IEC 60947-2
- Rated impulse withstand voltage (Uimp): 6 kV per EN/IEC 60947-2
- Overvoltage category: IV
- Pollution degree: 3 per EN/IEC 60947-2
- IP rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70°C
- Storage temperature: -40 to 85°C
- Relative humidity: 95% at 55°C
- Tropicalization: Class 2 per IEC 60068-1
- Mounting: DIN rail, fixed
- Dimensions (W x H x D): 54 x 85 x 78.5 mm
- Weight: 0.375 kg
- Connection: Single terminal block (upper or lower), 1-25 mm² rigid / 1-16 mm² flexible
- Strip length: 14 mm; tightening torque: 2 N.m
- Comb busbar distribution block: Compatible, upper or lower
- Mechanical durability: 20,000 cycles
- Electrical durability: 10,000 cycles
- Color: White
- Standards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2
Features and benefits:
- B tripping curve provides overcurrent protection suited to circuits with low starting currents
- Suitable for use as an isolating device per EN 60898-1 and EN 60947-2
- Compatible with comb busbar distribution blocks on upper or lower terminals for flexible panel wiring
- Trip indicator enables local fault signaling without additional instrumentation
- Tropicalized construction (Class 2 per IEC 60068-1) for reliable operation in demanding environments
- High mechanical durability rated at 20,000 operating cycles
Applications:
- Final distribution boards for electrical energy distribution in residential and commercial installations
- Industrial switchgear panels requiring 3-pole B-curve overcurrent protection
- DC circuit protection up to 180 V in low-voltage DC distribution systems
- DIN rail mounted assemblies with comb busbar connectivity
- Control panels requiring an isolating-rated MCB per IEC 60947-2
Compliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F73302, Schneider Electric A9F73302, iC60N 3P 2A B curve MCB, Acti9 miniature circuit breaker.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.