Schneider A9D31606 Acti9 iDPN N Vigi RCBO 1P+N 6 A C 30mA Type AC
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9D31606 is a 1P+N RCBO from the Acti 9 iDPN N Vigi series, rated 6 A with a C tripping curve and 30 mA Type AC residual current sensitivity. It combines thermomagnetic overcurrent protection with integrated earth fault detection and a breaking capacity of 6000 A Icn at 230-240 V AC 50 Hz.
Technical specifications:
- Commercial reference: A9D31606
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iDPN N Vigi
- Product type: RCBO (Residual Current Breaker with Overcurrent protection)
- Number of poles: 1P+N
- Rated current [In]: 6 A
- Tripping curve: C
- Overcurrent tripping range: 5-10 x In
- Rated voltage [Ue]: 230-240 V AC 50 Hz
- Breaking capacity [Icn]: 6000 A at 230-240 V AC (EN/IEC 61009-2-1)
- Service breaking capacity [Ics]: 6000 A (100% Icn)
- Residual current sensitivity: 30 mA
- RCD class: Type AC
- RCD tripping delay: Instantaneous
- Rated insulation voltage [Ui]: 400 V AC
- Impulse withstand voltage [Uimp]: 4 kV
- Limitation class: 3 (EN/IEC 61009-2-1)
- Mounting: DIN rail, clip-on
- Dimensions (WxHxD): 36 x 85 x 73 mm
- Weight: 125 g
- IP rating: IP20 / IP40 in modular enclosure (IEC 60529)
- Operating temperature: -5 to 60°C
- Connection terminals: 1-16 mm² solid / 1-10 mm² flexible, tightening torque 2 N.m
- Mechanical / electrical endurance: 20,000 cycles
- Certifications: VDE, GOST
Features and benefits:
- Integrated residual current protection removes the need for a separate RCD device
- Instantaneous tripping for rapid response to earth faults and leakage currents
- Suitable for isolation duty per EN/IEC 60947-2
- Compatible with comb busbar connection blocks on upper or lower terminals
- ON, OFF, and Fault trip local signaling for clear panel status indication
Applications:
- Residential consumer units and final distribution boards
- Protection of socket outlet circuits against overcurrent and earth faults
- Commercial electrical panels requiring combined RCBO protection
- Single-phase circuits in light industrial and commercial installations
Compliant with EN/IEC 61009-2-1 and suitable for isolation per EN/IEC 60947-2. Part of the Schneider Electric Acti 9 range.
Also known as: Schneider A9D31606, Schneider Electric A9D31606, Schneider iDPN N Vigi RCBO 6A 30mA.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.