{"title":"Type AC RCDs (RCCB and RCBO)","description":"\u003cp\u003eType AC residual current devices detect sinusoidal AC residual current.\u003c\/p\u003e\u003cp\u003eThey suit circuits with simple resistive loads such as heating and lighting, where no DC fault current is expected. For circuits with electronics, inverters or EV chargers, choose Type A or higher.\u003c\/p\u003e","products":[{"product_id":"a9d20610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-10a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D20610 Acti9 DPN Vigi K RCBO 1P+N C 10A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric Acti 9 DPN Vigi K (A9D20610) is a 1P+N residual current breaker with overcurrent protection (RCBO) from the Acti 9 range, combining earth-fault and overcurrent protection in a single device for final circuit protection in residential and commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D20610\u003c\/li\u003e\n\u003cli\u003eModel: Acti 9 DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA, type AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326006536,"sku":"SCHA9D20610","price":26.42,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9d20610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-10a-c-curve-6000a-ac-type-30ma-349862.jpg?v=1745440437"},{"product_id":"a9d20616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-16a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D20616 Acti9 DPN Vigi K RCBO 1P+N C 16A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric Acti 9 A9D20616 DPN Vigi K is a 1P+N RCBO (residual current circuit breaker with integral overcurrent protection) from the Acti 9 range, providing combined protection of final circuits against overcurrents and earth faults in residential and commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D20616\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity (IdN): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326104840,"sku":"SCHA9D20616","price":28.66,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d20616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-16a-c-curve-6000a-ac-type-30ma-630831.jpg?v=1735229809"},{"product_id":"a9d20620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-20a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D20620 Acti9 DPN Vigi K RCBO 1P+N C 20A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric Acti9 DPN Vigi K (A9D20620) is a 1P+N RCBO combining overcurrent and residual-current protection in a single device, part of the Acti 9 modular range for residential and commercial distribution boards.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D20620\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (Residual Current Breaker with Overcurrent Protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 20 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eResidual-current sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326235912,"sku":"SCHA9D20620","price":26.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d20620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-20a-c-curve-6000a-ac-type-30ma-953303.jpg?v=1735229810"},{"product_id":"a9d22616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-16a-b-curve-6000a-ac-type-30ma","title":"Schneider A9D22616 Acti9 DPN Vigi K RCBO 1P+N B 16A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric A9D22616 is a 1P+N RCBO (residual current circuit breaker with overcurrent protection) from the Acti 9 DPN Vigi K range, providing combined overload, short-circuit, and earth-fault protection on single-phase circuits in residential and commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D22616\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326399752,"sku":"SCHA9D22616","price":31.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d22616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-16a-b-curve-6000a-ac-type-30ma-382724.jpg?v=1735229809"},{"product_id":"a9d22620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1p-n-20a-b-curve-6000a-ac-type-30ma","title":"Schneider A9D22620 Acti9 DPN Vigi K RCBO 1P+N B 20A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric Acti9 DPN Vigi K (A9D22620) is a 1P+N RCBO that combines overcurrent protection and residual-current protection in a single module, for use in final circuits of single-phase 220-240 V AC domestic and light commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D22620\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: DPN Vigi K\u003c\/li\u003e\n\u003cli\u003eType: RCBO (Residual Current Circuit Breaker with Overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 20 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: B\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 220...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326498056,"sku":"SCHA9D22620","price":25.87,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d22620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-vigi-k-1pn-20a-b-curve-6000a-ac-type-30ma-526488.jpg?v=1735229811"},{"product_id":"a9d31606-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-6a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D31606 Acti9 iDPN N Vigi RCBO 1P+N 6A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric A9D31606 is an Acti9 iDPN N Vigi RCBO (residual current circuit breaker with overcurrent protection), combining overload, short-circuit, and earth-leakage protection in a compact 1P+N format for single-phase circuits.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D31606\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: Type AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326661896,"sku":"SCHA9D31606","price":40.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d31606-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-6a-c-curve-6000a-ac-type-30ma-519343.jpg?v=1735229811"},{"product_id":"a9d31610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-10a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D31610 Acti9 iDPN N Vigi RCBO 1P+N 10A 6kA 30mA AC","description":"\u003cp\u003eThe Schneider Electric A9D31610 is a 1P+N RCBO from the Acti 9 range, combining overcurrent and residual-current protection in a single module for single-phase circuits in residential and commercial distribution boards.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D31610\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual-current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eResidual-current sensitivity (IΔn): 30 mA, Type AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326792968,"sku":"SCHA9D31610","price":38.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d31610-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-10a-c-curve-6000a-ac-type-30ma-365929.jpg?v=1735229809"},{"product_id":"a9d31616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-16a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D31616 Acti9 iDPN N Vigi RCBO 1P+N 16A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric A9D31616 is an Acti 9 iDPN N Vigi RCBO (residual current circuit breaker with overcurrent protection), combining residual current and overcurrent protection in a single 1P+N module for single-phase 230-240 V AC installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D31616\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (residual current circuit breaker with overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IdN): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065326891272,"sku":"SCHA9D31616","price":38.79,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d31616-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-16a-c-curve-6000a-ac-type-30ma-797662.jpg?v=1735229810"},{"product_id":"a9r41225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-ac-type-30ma","title":"Schneider A9R41225 Acti9 iID RCCB 2P 25A 30mA AC","description":"\u003cp\u003eThe Schneider Electric A9R41225 is an Acti 9 iID residual current circuit breaker (RCCB), providing 30 mA earth leakage protection in a 2-pole configuration for circuits rated 220-240 V AC 50\/60 Hz.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R41225\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: Residual current circuit breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220...240 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333248264,"sku":"SCHA9R41225","price":31.36,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-ac-type-30ma-469002.jpg?v=1735231385"},{"product_id":"a9r41240-residual-current-circuit-breaker-rccb-acti9-iid-2p-40a-ac-type-30ma","title":"Schneider A9R41240 Acti9 iID RCCB 2P 40A 30mA AC Type","description":"\u003cp\u003eThe Schneider Electric Acti9 iID (reference A9R41240) is a 2-pole residual current circuit breaker (RCCB) from the Acti9 range, providing earth-leakage protection in residential and commercial low-voltage installations. It offers no overcurrent protection and must be used in conjunction with a suitable overcurrent protective device.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R41240\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: RCCB (residual current circuit breaker, no overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current In: 40 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity IΔn: 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage Ue: 220...240 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333313800,"sku":"SCHA9R41240","price":32.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41240-residual-current-circuit-breaker-rccb-acti9-iid-2p-40a-ac-type-30ma-375306.jpg?v=1735231385"},{"product_id":"a9r41425-residual-current-circuit-breaker-rccb-acti9-iid-4p-25a-ac-type-30ma","title":"Schneider A9R41425 Acti9 iID RCCB 4P 25A 30mA AC","description":"\u003cp\u003eThe A9R41425 is a 4-pole RCCB from the Schneider Electric Acti 9 iID range, providing residual-current earth-fault protection for three-phase and neutral AC installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R41425\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 380...415 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333379336,"sku":"SCHA9R41425","price":44.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41425-residual-current-circuit-breaker-rccb-acti9-iid-4p-25a-ac-type-30ma-348688.jpg?v=1735231384"},{"product_id":"a9r41440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma","title":"Schneider A9R41440 Acti9 iID RCCB 4P 40A 30mA AC","description":"\u003cp\u003eThe Schneider Electric A9R41440 is an Acti 9 iID 4-pole residual current circuit breaker (RCCB) providing earth-fault and personnel protection in three-phase installations. It offers residual-current tripping without integrated overcurrent protection.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R41440\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: RCCB (residual current circuit breaker)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 380...415 V AC 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333412104,"sku":"SCHA9R41440","price":42.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma-862931.jpg?v=1735231384"},{"product_id":"a9z05225-residual-current-circuit-breaker-rccb-acti9-id-k-2p-25a-ac-type-30ma","title":"Schneider A9Z05225 Acti9 ID K RCCB 2P 25A 30mA AC","description":"\u003cp\u003eThe Schneider Electric Acti9 ID K (A9Z05225) is a 2-pole residual current circuit breaker (RCCB) from the Acti 9 modular range, providing earth fault protection without overcurrent protection, for use in domestic and commercial installations operating at 220-240 V AC 50 Hz.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9Z05225\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: ID K\u003c\/li\u003e\n\u003cli\u003eType: RCCB (residual current circuit breaker, no overcurrent protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220...240 V AC 50 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065336492296,"sku":"SCHA9Z05225","price":18.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9z05225-residual-current-circuit-breaker-rccb-acti9-id-k-2p-25a-ac-type-30ma-668883.jpg?v=1735231609"},{"product_id":"a9z05240-residual-current-circuit-breaker-rccb-acti9-id-k-2p-40a-ac-type-30ma","title":"Schneider A9Z05240 Acti9 ID K RCCB 2P 40A 30mA AC","description":"\u003cp\u003eThe Schneider Electric A9Z05240 is an Acti9 ID K 2-pole residual current circuit breaker (RCCB), providing protection against earth-leakage currents in residential and commercial installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9Z05240\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: ID K\u003c\/li\u003e\n\u003cli\u003eType: RCCB (residual current circuit breaker)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 220-240 V AC 50 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065336557832,"sku":"SCHA9Z05240","price":21.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9z05240-residual-current-circuit-breaker-rccb-acti9-id-k-2p-40a-ac-type-30ma-720064.jpg?v=1735231609"},{"product_id":"a9z05425-residual-current-circuit-breaker-rccb-acti9-id-k-4p-25a-ac-type-30ma","title":"Schneider A9Z05425 Acti9 ID K RCCB 4P 25A 30mA AC","description":"\u003cp\u003eThe Schneider Electric Acti9 ID K (A9Z05425) is a 4-pole residual current circuit breaker (RCCB) from the Acti9 modular device range, designed to provide protection against earth fault currents in three-phase and neutral AC installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9Z05425\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: ID K\u003c\/li\u003e\n\u003cli\u003eType: Residual current circuit breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 380-415 V AC 50 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065336688904,"sku":"SCHA9Z05425","price":23.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9z05425-residual-current-circuit-breaker-rccb-acti9-id-k-4p-25a-ac-type-30ma-804557.jpg?v=1735231609"},{"product_id":"a9z05440-residual-current-circuit-breaker-rccb-acti9-id-k-4p-40a-ac-type-30ma","title":"Schneider A9Z05440 Acti9 ID K RCCB 4P 40A 30mA AC","description":"\u003cp\u003eThe Schneider Electric Acti9 ID K (A9Z05440) is a 4-pole residual current circuit breaker (RCCB) from the Acti 9 range, providing AC-type residual current protection in electrical installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9Z05440\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: ID K\u003c\/li\u003e\n\u003cli\u003eType: RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 380...415 V AC 50 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065337213192,"sku":"SCHA9Z05440","price":28.98,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9z05440-residual-current-circuit-breaker-rccb-acti9-id-k-4p-40a-ac-type-30ma-871076.jpg?v=1735231609"},{"product_id":"a9d31620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-20a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D31620 Acti9 iDPN N Vigi RCBO 1P+N 20A 6kA 30mA","description":"\u003cp\u003eThe Schneider Electric A9D31620 is the Acti 9 iDPN N Vigi RCBO, providing combined overcurrent and residual-current protection on single-phase 1P+N final circuits at 230-240 V AC 50 Hz.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D31620\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (Residual Current Circuit Breaker with Overcurrent Protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 20 A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eResidual-current sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230-240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44074985521416,"sku":"SCHA9D31620","price":38.86,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d31620-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-20a-c-curve-6000a-ac-type-30ma-357116.jpg?v=1735229809"},{"product_id":"a9d31625-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1p-n-25a-c-curve-6000a-ac-type-30ma","title":"Schneider A9D31625 Acti9 iDPN N Vigi RCBO 1P+N 25A 30mA 6kA","description":"\u003cp\u003eThe Schneider Electric A9D31625 is an Acti 9 iDPN N Vigi residual current circuit breaker with overcurrent protection (RCBO), providing combined earth-fault and overcurrent protection for single-phase circuits in a compact 1P+N format.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9D31625\u003c\/li\u003e\n\u003cli\u003eRange: Acti 9\u003c\/li\u003e\n\u003cli\u003eModel: iDPN N Vigi\u003c\/li\u003e\n\u003cli\u003eType: RCBO (Residual Current Circuit Breaker with Overcurrent Protection)\u003c\/li\u003e\n\u003cli\u003ePoles: 1P + N\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Icn): 6000 A at 230...240 V AC 50 Hz per EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eRCD type: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 230...240 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eStandard: EN\/IEC 61009-2-1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44074985554184,"sku":"SCHA9D31625","price":41.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9d31625-residual-current-breaker-with-overcurrent-protection-rcbo-acti9-idpn-n-vigi-1pn-25a-c-curve-6000a-ac-type-30ma-195021.jpg?v=1735229810"},{"product_id":"a9r11440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma","title":"Schneider A9R11440 Acti9 iID RCCB 4P 40A 30mA AC Type","description":"\u003cp\u003eThe Schneider Electric Acti9 iID (A9R11440) is a 4-pole residual current circuit breaker (RCCB) from the Acti9 range, providing residual current protection against earth faults in residential and commercial electrical installations.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReference: A9R11440\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eModel: iID\u003c\/li\u003e\n\u003cli\u003eType: Residual current circuit breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 40A\u003c\/li\u003e\n\u003cli\u003eRCD type: AC type\u003c\/li\u003e\n\u003cli\u003eRCD sensitivity: 30mA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075764154632,"sku":"SCHA9R11440","price":35.02,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r11440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma-767861.jpg?v=1735231322"},{"product_id":"286492-pf6-25-2-003-residual-current-circuit-breaker-2p-25a-30ma","title":"Eaton 286492 PF6-25\/2\/003 RCCB 2P 25 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-25\/2\/003 is a 2-pole Type AC RCCB from the Moeller series xPole range, rated at 25 A with a 30 mA fault current threshold and 6 kA breaking capacity. Partly surge-proof at 250 A, it protects residential and commercial circuits from earth leakage currents on standard DIN rail.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-25\/2\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286492\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082864927\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eResidual current (IN): 30 mA, Type AC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC, 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eSurge protection: Partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eBack-up fuse: max. 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm; built-in width: 2 SU (35 mm)\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 55 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConductor cross section (solid-core): 1.5-35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross section (multi-wired): 1.5-16 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminals: Open mouthed\/lift, touch safe, EN 50274\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensitivity detects sinusoidal AC residual currents reliably\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping from transient currents\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals comply with DGUV VS3 and EN 50274\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-FW\/LP remote control device and Z-RC\/AK-2TE sealing cover accessories\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail attachment with 2 latch positions for fast and secure installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth leakage protection in residential consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical distribution boards and panels\u003c\/li\u003e\n  \u003cli\u003eOffice and retail final circuit protection\u003c\/li\u003e\n  \u003cli\u003ePanel assemblies using the KLV-TC-2 compact enclosure\u003c\/li\u003e\n  \u003cli\u003eCircuits requiring remote switching via Z-FW\/LP automatic switching device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-25\/2\/003, Eaton 286492, Eaton catalog 286492, Eaton model PF6-25\/2\/003, Eaton xPole 25A 2-pole RCCB 30mA.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251474886920,"sku":"ETN286492","price":17.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286492-pf6-252003-residual-current-circuit-breaker-2p-25a-30ma-877687.jpg?v=1735225452"},{"product_id":"286496-pf6-40-2-003-residual-current-circuit-breaker-2p-40a-30ma","title":"Eaton 286496 PF6-40\/2\/003 RCCB 2P 40 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-40\/2\/003 is a 2-pole residual current circuit breaker (RCCB) from the Eaton Moeller xPole series, rated at 40 A with a 30 mA trip threshold and Type AC sensitivity. It delivers a conditional short-circuit current rating of 6 kA and is partly surge-proof up to 250 A for reliable earth leakage protection in residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-40\/2\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286496\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082864965\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB, Type AC\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eRated residual operating current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eConditional short-circuit rating (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: Partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse (overload): max 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eShort-circuit rating (max. back-up fuse): 63 A\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 35 mm (2 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25-55 °C \/ 90-95% relative humidity per IEC 60068-2\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (solid): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (multi-wire): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminal type: Open mouthed\/lift terminals\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: Finger and hand touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 - 250 V AC\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 5.8 W\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eCertification: IEC\/EN 61008\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePartly surge-proof up to 250 A reduces nuisance tripping caused by transient impulse currents\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail attachment with 2 latch positions enables fast, tool-free installation\u003c\/li\u003e\n  \u003cli\u003eOpen mouthed\/lift terminals accept solid conductors up to 35 mm² for flexible wiring\u003c\/li\u003e\n  \u003cli\u003eCompatible with optional accessories: remote control device Z-FW\/LP 248296, sealing cover set Z-RC\/AK-2TE 285385, and tripping signal contact Z-NHK 248434\u003c\/li\u003e\n  \u003cli\u003eWide operating range from -25 °C to 60 °C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eFinger and hand touch-safe terminal design per DGUV VS3 and EN 50274 for enhanced installer safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePersonal protection against earth faults in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial installations requiring 30 mA residual current protection per local wiring regulations\u003c\/li\u003e\n  \u003cli\u003eFinal circuits supplying socket outlets, bathroom equipment, and outdoor loads\u003c\/li\u003e\n  \u003cli\u003eUse with compact enclosure KLV-TC-2 276240 for pre-assembled distribution assemblies\u003c\/li\u003e\n  \u003cli\u003eRetrofit installations where surge-robust residual current protection is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-40\/2\/003, Eaton 286496, Eaton catalog 286496, Eaton model PF6-40\/2\/003, Eaton xPole RCCB 40 A 30 mA 2-pole, Eaton Moeller PF6 RCCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251474985224,"sku":"ETN286496","price":22.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286496-pf6-402003-residual-current-circuit-breaker-2p-40a-30ma-664645.jpg?v=1735225452"},{"product_id":"286500-pf6-63-2-003-residual-current-circuit-breaker-2p-63a-30ma","title":"Eaton 286500 PF6-63\/2\/003 RCCB 2P 63 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-63\/2\/003 is a two-pole Type AC residual current circuit breaker from the Moeller series xPole range, providing earth leakage protection in residential and commercial installations. Rated at 63 A with a 30 mA residual operating current and 6 kA short-circuit rating, it is partly surge-proof to 250 A for reduced nuisance tripping. DIN rail mounting in a compact 2 SU width makes it easy to integrate into standard switchgear assemblies.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-63\/2\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286500\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865009\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 63 A\u003c\/li\u003e\n  \u003cli\u003eResidual operating current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: AC\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icw): 6 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: 250 A (partly surge-proof)\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 V AC - 250 V AC\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: 40 A gG\/gL max\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 35 mm (2 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25 - 55 °C \/ 90 - 95% relative humidity (IEC 60068-2)\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section, solid-core: 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section, multi-wired: 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eTerminal type: Open mouthed\/lift terminals, finger and touch safe (DGUV VS3, EN 50274)\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 9.7 W\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n  \u003cli\u003eAccessories required: Z-HK 248432\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensitivity detects sinusoidal residual fault currents for standard residential and commercial circuit protection\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping caused by transient current impulses\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail attachment with 2 latch positions enables fast installation without additional tools\u003c\/li\u003e\n  \u003cli\u003eFinger and touch-safe terminals comply with DGUV VS3 and EN 50274 for safe wiring work\u003c\/li\u003e\n  \u003cli\u003eWide operating range of -25 °C to 60 °C suits demanding panel environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with xPole accessories including remote control device Z-FW\/LP (248296) and sealing cover Z-RC\/AK-2TE (285385)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth leakage protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eMain or sub-circuit RCCB in commercial electrical installations\u003c\/li\u003e\n  \u003cli\u003eFinal circuit protection up to 63 A alongside MCBs in DIN rail assemblies\u003c\/li\u003e\n  \u003cli\u003eIntegration into compact enclosures such as KLV-TC-2 (catalog 276240)\u003c\/li\u003e\n  \u003cli\u003eSwitchgear panels requiring Type AC residual current protection with surge immunity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-63\/2\/003, Eaton 286500, Eaton catalog 286500, Eaton model PF6-63\/2\/003, Eaton xPole RCCB 63A 30mA, Eaton Moeller PF6 RCCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475017992,"sku":"ETN286500","price":32.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286500-pf6-632003-residual-current-circuit-breaker-2p-63a-30ma-652634.jpg?v=1735225452"},{"product_id":"286504-pf6-25-4-003-residual-current-circuit-breaker-4p-25a-30ma","title":"Eaton 286504 PF6-25\/4\/003 RCCB 4P 25 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-25\/4\/003 is a four-pole Type AC residual current circuit breaker from the Moeller series xPole range, rated at 25 A with 30 mA fault-current sensitivity. It carries a 6 kA conditional short-circuit rating and is partly surge-proof to 250 A, protecting residential and commercial 230\/400 V AC circuits against earth faults.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-25\/4\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286504\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865047\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: Four-pole\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eFault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eConditional short-circuit current (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 55 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid-core): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (multi-wired): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eMax. admissible back-up fuse: 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: Finger and hand touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensitivity detects sinusoidal alternating residual currents for reliable earth-fault protection\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof to 250 A, reducing nuisance tripping caused by transient overvoltages\u003c\/li\u003e\n  \u003cli\u003eQuick snap-on DIN rail attachment with 2 latch positions for fast installation\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals accept conductors from 1.5 to 35 mm²\u003c\/li\u003e\n  \u003cli\u003eWide temperature range of -25 °C to 55 °C with IEC 60068-2 climatic proofing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential distribution boards and consumer unit sub-circuits\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical installations requiring 30 mA earth-fault protection\u003c\/li\u003e\n  \u003cli\u003eCircuits protected by back-up fuses up to 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eSystems integrating the Z-FW\/LP remote switching device or KLV-TC-4 compact enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole PF6\/7 RCCB range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-25\/4\/003, Eaton 286504, Eaton catalog 286504, Eaton model PF6-25\/4\/003, xPole RCCB 25A 4-pole 30mA Type AC.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475083528,"sku":"ETN286504","price":23.47,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286504-pf6-254003-residual-current-circuit-breaker-4p-25a-30ma-964628.jpg?v=1735225455"},{"product_id":"286508-pf6-40-4-003-residual-current-circuit-breaker-4p-40a-30ma","title":"Eaton 286508 PF6-40\/4\/003 RCCB 4P 40 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-40\/4\/003 is a four-pole Type AC residual current circuit breaker (RCCB) from the Eaton Moeller series xPole range, providing earth-fault protection in residential and commercial installations. Rated at 40 A with a 30 mA residual operating current and a conditional short-circuit rating of 6 kA, it delivers reliable protection against indirect contact and fire hazards. Partly surge-proof to 250 A, it minimises nuisance tripping caused by transient discharge currents.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-40\/4\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286508\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865085\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eResidual operating current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: AC\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icw): 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 - 440 V AC\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: max 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eShort-circuit rating: 63 A (max. admissible back-up fuse)\u003c\/li\u003e\n  \u003cli\u003eMounting method: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 70 mm (4 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eTerminals: open mouthed\/lift terminals\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: finger and hand touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section solid-core: 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section multi-wired: 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003ePermitted storage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25 - 55 °C \/ 90 - 95% relative humidity (IEC 60068-2)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 13.1 W\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS conform\u003c\/li\u003e\n  \u003cli\u003eAccessories required: Z-HK 248432\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping from transient discharge currents\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals (DGUV VS3, EN 50274) for safer wiring\u003c\/li\u003e\n  \u003cli\u003eWide conductor range (1.5 - 35 mm² solid-core) suits diverse cable configurations\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail snap-on with 2 latch positions enables fast panel assembly\u003c\/li\u003e\n  \u003cli\u003eCompatible with remote control and automatic switching device Z-FW\/LP 248296\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25 °C to 60 °C) suits varied installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth-fault protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building sub-distribution panels in offices, retail, and hotels\u003c\/li\u003e\n  \u003cli\u003eProtection of socket outlet circuits and fixed appliance circuits\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring remote or automated RCD switching\u003c\/li\u003e\n  \u003cli\u003eLight industrial premises requiring Type AC RCCB protection to IEC\/EN 61008\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole switchgear range, designed for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-40\/4\/003, Eaton 286508, Eaton catalog 286508, Eaton model PF6-40\/4\/003, Eaton xPole RCCB 40 A 4-pole 30 mA Type AC.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475149064,"sku":"ETN286508","price":27.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286508-pf6-404003-residual-current-circuit-breaker-4p-40a-30ma-144365.jpg?v=1735225450"},{"product_id":"286512-pf6-63-4-003-residual-current-circuit-breaker-4p-63a-30ma","title":"Eaton 286512 PF6-63\/4\/003 RCCB 4P 63 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe PF6-63\/4\/003 is a four-pole Type AC residual current circuit breaker (RCCB) from Eaton's Moeller xPole series, rated at 63 A with a 30 mA fault current threshold for reliable earth fault protection. With a 6 kA short-circuit rating and partial surge immunity up to 250 A, it is suited for residential and commercial low-voltage distribution boards. Quick DIN rail attachment and finger-safe open mouthed lift terminals simplify installation in switchgear assemblies up to 400 V AC.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-63\/4\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286512\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865122\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB, Type AC, AC current sensitive\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 63 A\u003c\/li\u003e\n  \u003cli\u003eFault current rating (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eShort-circuit rating (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: 250 A (partly surge-proof)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 V AC - 440 V AC\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: max 40 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25-55 °C \/ 90-95% relative humidity per IEC 60068-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 70 mm (4 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (L x H x W): 76 x 80 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor, multi-wire: 1.5 mm² - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor, solid-core: 1.5 mm² - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 mm - 2 mm\u003c\/li\u003e\n  \u003cli\u003eTerminal type: Open mouthed\/lift terminals\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: Finger and hand touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 13.4 W\u003c\/li\u003e\n  \u003cli\u003eAccessories required: Z-HK 248432\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensing detects sinusoidal AC residual fault currents\u003c\/li\u003e\n  \u003cli\u003ePartial surge protection up to 250 A reduces nuisance tripping from transient currents\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail latch with 2 positions enables fast, secure panel installation\u003c\/li\u003e\n  \u003cli\u003eFinger and touch-safe open mouthed lift terminals comply with EN 50274 and DGUV VS3\u003c\/li\u003e\n  \u003cli\u003eOperating range down to -25 °C suits installations in unheated environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-NHK 248434 tripping signal contact and Z-FW\/LP 248296 remote control for extended functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault protection in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical panels requiring 30 mA RCD protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage switchgear assemblies operating at 230 V AC or 400 V AC\u003c\/li\u003e\n  \u003cli\u003eRetrofit into DIN rail enclosures such as the KLV-TC-4 276241 compact enclosure\u003c\/li\u003e\n  \u003cli\u003eInstallations where partial surge immunity is required to prevent spurious tripping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008, RoHS conform. Part of the Eaton Moeller xPole series of residual current circuit breakers.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-63\/4\/003, Eaton 286512, Eaton catalog 286512, Eaton model PF6-63\/4\/003, Eaton xPole RCCB 63A 4P 30mA, Eaton Moeller PF6 four-pole RCCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475214600,"sku":"ETN286512","price":43.02,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286512-pf6-634003-residual-current-circuit-breaker-4p-63a-30ma-847982.jpg?v=1735325460"},{"product_id":"411509-tx-residual-current-circuit-breaker-2p-25a-30ma-id","title":"Legrand 411509 RCCB TX³ 2P 25A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Legrand 411509 (catalog reference 4 115 09) is a TX³ residual current circuit breaker (RCCB), 2-pole, rated 25 A with 30 mA AC-type sensitivity for 230 V~ installations. It occupies 2 modules on a DIN rail and conforms to IEC 61008-1, providing personal protection from direct and indirect contact along with insulation-fault protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCatalog reference: 411509\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n  \u003cli\u003eEAN: 3414970352408\u003c\/li\u003e\n  \u003cli\u003eProduct type: TX³ RCCB (residual current circuit breaker)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 230 V~ (operating range 180-250 V~)\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eRated residual current (IΔn): 30 mA (0.03 A)\u003c\/li\u003e\n  \u003cli\u003eResidual current type: AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 250 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eShort-circuit conditional capacity (Icw): 10 kA\u003c\/li\u003e\n  \u003cli\u003eSurge current capacity: 0.25 kA\u003c\/li\u003e\n  \u003cli\u003eWidth: 2 modules \/ 35.6 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 88.9 mm; depth: 77.8 mm; built-in depth: 44 mm\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (EN 60715 \/ DIN 35)\u003c\/li\u003e\n  \u003cli\u003eConnection: screw terminals; busbar and cable compatible\u003c\/li\u003e\n  \u003cli\u003eCable cross-section: 0.75 to 50 mm² solid-core, 0.75 to 35 mm² multi-wired\u003c\/li\u003e\n  \u003cli\u003eCompatible with prong-type and fork-type supply busbars\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eImpact resistance: IK04\u003c\/li\u003e\n  \u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n  \u003cli\u003eAmbient temperature (operating): -25 to +60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to +70 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eHalogen-free\u003c\/li\u003e\n  \u003cli\u003eStandard: IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eElectromagnetic residual current sensing detects insulation faults and protects people from direct and indirect contact in IT, TT, and TN earthing systems.\u003c\/li\u003e\n  \u003cli\u003eInterlocking device supports lockout\/tagout procedures during maintenance.\u003c\/li\u003e\n  \u003cli\u003eBidirectional supply allows the device to be wired from the top or bottom of the enclosure.\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction reduces toxic emissions in the event of fire.\u003c\/li\u003e\n  \u003cli\u003eProng and fork busbar compatibility speeds up distribution-board assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential and commercial distribution boards requiring 30 mA residual-current personal protection.\u003c\/li\u003e\n  \u003cli\u003eInsulation-fault protection for lighting circuits, socket outlets, and general-purpose feeders.\u003c\/li\u003e\n  \u003cli\u003eSelective coordination with upstream protective devices in IT, TT, and TN-S supply systems.\u003c\/li\u003e\n  \u003cli\u003eDIN rail enclosures specifying a 2-module-wide 25 A RCCB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: Legrand 411509, TX³ RCCB 2P 25A 30mA Type AC, 4 115 09.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":44261650137352,"sku":"LGR411509","price":25.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/411509-tx3-residual-current-circuit-breaker-2p-25a-30ma-id-902141.jpg?v=1735226572"},{"product_id":"411510-tx-residual-current-circuit-breaker-2p-40a-30ma-id","title":"Legrand 411510 RCCB TX³ 2P 40A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Legrand 411510 (catalog reference 4 115 10) is a TX³ residual current circuit breaker (RCCB), 2-pole, rated 40 A with 30 mA AC-type sensitivity for 230 V~ installations. It occupies 2 modules on a DIN rail and conforms to IEC 61008-1, providing personal protection from direct and indirect contact along with insulation-fault protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCatalog reference: 411510\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n  \u003cli\u003eEAN: 3414970352422\u003c\/li\u003e\n  \u003cli\u003eProduct type: TX³ RCCB (residual current circuit breaker)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 230 V~ (operating range 180-250 V~)\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eRated residual current (IΔn): 30 mA (0.03 A)\u003c\/li\u003e\n  \u003cli\u003eResidual current type: AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 250 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eShort-circuit conditional capacity (Icw): 10 kA\u003c\/li\u003e\n  \u003cli\u003eSurge current capacity: 0.25 kA\u003c\/li\u003e\n  \u003cli\u003eWidth: 2 modules \/ 35.6 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 88.9 mm; depth: 77.8 mm; built-in depth: 44 mm\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (EN 60715 \/ DIN 35)\u003c\/li\u003e\n  \u003cli\u003eConnection: screw terminals; busbar and cable compatible\u003c\/li\u003e\n  \u003cli\u003eCable cross-section: 0.75 to 50 mm² solid-core, 0.75 to 35 mm² multi-wired\u003c\/li\u003e\n  \u003cli\u003eCompatible with prong-type and fork-type supply busbars\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eImpact resistance: IK04\u003c\/li\u003e\n  \u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n  \u003cli\u003eAmbient temperature (operating): -25 to +60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to +70 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eHalogen-free\u003c\/li\u003e\n  \u003cli\u003eStandard: IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eElectromagnetic residual current sensing detects insulation faults and protects people from direct and indirect contact in IT, TT, and TN earthing systems.\u003c\/li\u003e\n  \u003cli\u003eInterlocking device supports lockout\/tagout procedures during maintenance.\u003c\/li\u003e\n  \u003cli\u003eBidirectional supply allows the device to be wired from the top or bottom of the enclosure.\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction reduces toxic emissions in the event of fire.\u003c\/li\u003e\n  \u003cli\u003eProng and fork busbar compatibility speeds up distribution-board assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential and commercial distribution boards requiring 30 mA residual-current personal protection.\u003c\/li\u003e\n  \u003cli\u003eInsulation-fault protection for higher-current circuits (cookers, water heaters, EV charge points) up to 40 A.\u003c\/li\u003e\n  \u003cli\u003eSelective coordination with upstream protective devices in IT, TT, and TN-S supply systems.\u003c\/li\u003e\n  \u003cli\u003eDIN rail enclosures specifying a 2-module-wide 40 A RCCB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: Legrand 411510, TX³ RCCB 2P 40A 30mA Type AC, 4 115 10.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":44261650202888,"sku":"LGR411510","price":25.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/411510-tx3-residual-current-circuit-breaker-2p-40a-30ma-id-564397.jpg?v=1735226569"},{"product_id":"411707-tx-residual-current-circuit-breaker-4p-25a-30ma-id","title":"Legrand 411707 RCCB TX³ 4P 25A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Legrand 411707 is a residual current device, 4-pole, rated 25 A with 30 mA AC-type sensitivity for 400 V installations. It occupies 4 modules on a DIN rail and conforms to IEC 61008-1, providing personal protection from direct and indirect contact along with insulation-fault protection.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 411707\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970353061\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 71.2 × 88.9 × 78.85 mm\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRated residual current (IΔn): 0.03 A\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eResidual current type: AC\u003c\/li\u003e\n\u003cli\u003eShort-circuit conditional capacity (Icw): 10 kA\u003c\/li\u003e\n\u003cli\u003eSurge current capacity: 0.25 kA\u003c\/li\u003e\n\u003cli\u003eVoltage type: AC\u003c\/li\u003e\n\u003cli\u003eInterlocking device: Yes\u003c\/li\u003e\n\u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 4\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eAmbient temperature (operating): -25 to 60 °C\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eCable cross-section (multi-wired): 0.75-35 mm²\u003c\/li\u003e\n\u003cli\u003eCable cross-section (solid-core): 0.75-50 mm²\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK04\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 340-440 V\u003c\/li\u003e\n\u003cli\u003eHalogen-free: Yes\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eElectromagnetic residual current sensing detects insulation faults and protects people from direct and indirect contact.\u003c\/li\u003e\n\u003cli\u003eInterlocking device supports lockout\/tagout procedures during maintenance.\u003c\/li\u003e\n\u003cli\u003eHalogen-free construction reduces toxic emissions in the event of fire.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eResidential and commercial distribution boards requiring 30 mA residual-current personal protection.\u003c\/li\u003e\n\u003cli\u003eInsulation-fault protection for circuits up to 25 A.\u003c\/li\u003e\n\u003cli\u003eSelective coordination with upstream protective devices in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eDIN rail enclosures specifying a 2-module-wide RCD.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 411707, 411707, TX³ LEGRAND RCCB.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":44261650235656,"sku":"LGR411707","price":32.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/411707-tx3-residual-current-circuit-breaker-4p-25a-30ma-id-960774.jpg?v=1735226575"},{"product_id":"2csf204004r1250-fh204-ac-25-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204004R1250 FH204 RCCB 4P 25A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB FH204 AC-25\/0.03 (article 2CSF204004R1250) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 25 A with a 30 mA trip sensitivity. It shields people and electrical installations from earth fault currents, and is designed primarily for use in domestic applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: FH200 (model FH204 AC-25\/0.03)\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204004R1250\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542893905\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eType: AC (standard instantaneous)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4-pole design disconnects all live conductors simultaneously, covering three-phase plus neutral circuits in a single device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity provides personal protection against indirect contact with live parts\u003c\/li\u003e\n\u003cli\u003eType AC operation responds to sinusoidal residual currents, which are the fault type most commonly encountered in domestic settings\u003c\/li\u003e\n\u003cli\u003ePart of the FH200 range, which covers both AC and A type variants to suit a wide variety of residential installation requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eEarth fault protection for domestic socket outlet circuits\u003c\/li\u003e\n\u003cli\u003eProtection of household appliances in kitchens, bathrooms, and utility rooms\u003c\/li\u003e\n\u003cli\u003eGeneral 4-pole RCCB earth fault protection in home electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB FH204 AC-25\/0.03, FH204 AC-25\/0.03 2CSF204004R1250, ABB 2CSF204004R1250, 4-pole RCCB 25 A 30 mA Type AC, ABB FH200 RCCB.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750011695368,"sku":"ABB2CSF204004R1250","price":22.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204004r1250-fh204-ac-25003-residual-current-circuit-breaker-4p-ac-type-30-ma-251638.png?v=1735225733"},{"product_id":"2csf204004r1400-fh204-ac-40-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204004R1400 FH204 RCCB 4P 40A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB FH204 AC-40\/0.03 (article 2CSF204004R1400) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 40 A with a 30 mA earth fault tripping threshold. It is designed to protect both people and electrical installations from fault currents flowing to earth. The Type AC tripping characteristic makes this device well suited for standard domestic installation environments.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: FH204 AC-40\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204004R1400\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542894001\u003c\/li\u003e\n\u003cli\u003eProduct family: FH200\u003c\/li\u003e\n\u003cli\u003ePoles: 4P (4-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30 mA\u003c\/li\u003e\n\u003cli\u003eTripping type: Type AC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole design protects all four conductors in a single device, covering both live and neutral conductors across the circuit\u003c\/li\u003e\n\u003cli\u003e30 mA residual current rating provides sensitive earth fault detection, safeguarding people and installations from leakage currents\u003c\/li\u003e\n\u003cli\u003eStandard instantaneous Type AC tripping covers typical earth fault conditions encountered in domestic wiring\u003c\/li\u003e\n\u003cli\u003ePart of the FH200 series, which includes both AC and A type variants across a broad range of ratings for domestic use\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDomestic distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eProtection of final circuits in residential properties and apartments\u003c\/li\u003e\n\u003cli\u003e4-pole earth fault protection in new-build and retrofit home installations\u003c\/li\u003e\n\u003cli\u003eGeneral residential electrical installations requiring standard Type AC protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB FH204 AC-40\/0.03, FH204 AC-40\/0.03 2CSF204004R1400, ABB 2CSF204004R1400, 4-pole RCCB 40 A 30 mA Type AC, FH200 4P RCCB.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750011859208,"sku":"ABB2CSF204004R1400","price":28.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204004r1400-fh204-ac-40003-residual-current-circuit-breaker-4p-ac-type-30-ma-709594.png?v=1735225733"},{"product_id":"2csf204004r1630-fh204-ac-63-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204004R1630 FH204 RCCB 4P 63A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB FH204 AC-63\/0.03 (article 2CSF204004R1630) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 63 A with a residual current sensitivity of 30 mA. It guards people and electrical installations from earth fault currents by disconnecting the circuit when leakage current exceeds the 30 mA threshold. Its Type AC classification means the device responds to sinusoidal alternating residual currents, as encountered in standard domestic wiring.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: FH204 AC-63\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204004R1630\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542894100\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 63 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTrip type: AC - instantaneous, sinusoidal alternating residual current\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole design disconnects all circuit conductors simultaneously on fault detection, providing complete isolation\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity trips the breaker well below current levels considered dangerous for people, supporting personal protection\u003c\/li\u003e\n\u003cli\u003eType AC operation covers sinusoidal alternating residual currents typical of standard domestic loads\u003c\/li\u003e\n\u003cli\u003ePart of the FH200 range, which spans both AC and A type variants, giving installers a consistent product family across multiple specifications\u003c\/li\u003e\n\u003cli\u003eOptimised for domestic applications, making it a straightforward fit for residential distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eResidential consumer units and distribution boards\u003c\/li\u003e\n\u003cli\u003eEarth fault protection on final sub-circuits in homes and apartments\u003c\/li\u003e\n\u003cli\u003eSocket-outlet circuits requiring protection against electric shock\u003c\/li\u003e\n\u003cli\u003eDomestic installations where a 4-pole 63 A RCCB is specified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB FH204 AC-63\/0.03, FH204 AC-63\/0.03 2CSF204004R1630, ABB 2CSF204004R1630, ABB RCCB 4P 63A 30mA Type AC, residual current circuit breaker 4 pole 63 A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750011891976,"sku":"ABB2CSF204004R1630","price":53.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204004r1630-fh204-ac-63003-residual-current-circuit-breaker-4p-ac-type-30-ma-802042.png?v=1735225733"},{"product_id":"2csf204001r1250-f204-ac-25-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204001R1250 F204 RCCB 4P 25A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB F204 AC-25\/0.03 (article 2CSF204001R1250) is a 4-pole residual current circuit breaker from the ABB F200 series, rated at 25 A with a 30 mA residual current sensitivity. It protects people and electrical installations by disconnecting the circuit when earth leakage current exceeds the 30 mA threshold. As a Type AC device, it is designed to detect sinusoidal alternating residual currents in standard installations.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F204 AC-25\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204001R1250\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542781202\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eOperating type: AC (standard instantaneous)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole design switches all live conductors simultaneously, covering three-phase and neutral circuits in a single device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity threshold provides personal protection against electric shock from earth fault currents\u003c\/li\u003e\n\u003cli\u003eType AC classification makes it suited to general installations where sinusoidal AC residual currents are expected\u003c\/li\u003e\n\u003cli\u003ePart of the F200 series, which spans a broad range of instantaneous and selective AC and A type configurations\u003c\/li\u003e\n\u003cli\u003eThe wider F200 family also includes variants for special applications, allowing system designers to select the right device for each circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEarth fault protection in three-phase residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eSafeguarding personnel and fixed installations from leakage current faults\u003c\/li\u003e\n\u003cli\u003eConsumer units and switchgear panels requiring 4-pole RCCB protection at 25 A\u003c\/li\u003e\n\u003cli\u003eGeneral electrical installations where Type AC earth fault detection is appropriate\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F204 AC-25\/0.03, F204 AC-25\/0.03 2CSF204001R1250, ABB 2CSF204001R1250, 4-pole RCCB 25 A 30 mA Type AC, ABB F200 RCCB 4P 25A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750014808328,"sku":"ABB2CSF204001R1250","price":41.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204001r1250-f204-ac-25003-residual-current-circuit-breaker-4p-ac-type-30-ma-374253.png?v=1735225740"},{"product_id":"2csf204001r1400-f204-ac-40-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204001R1400 F204 RCCB 4P 40A 30mA Type AC DIN Rail","description":"\u003cp\u003eABB F204 AC-40\/0.03 (article 2CSF204001R1400) is a 4-pole, 40 A residual current circuit breaker from the ABB F200 series with a 30 mA trip sensitivity. As a Type AC device, it trips on sinusoidal alternating residual currents to earth and is designed to guard both people and electrical installations against the hazards of earth leakage faults.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F204 AC-40\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204001R1400\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542781301\u003c\/li\u003e\n\u003cli\u003eType: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P (4-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTrip type: Type AC - standard instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole design simultaneously disconnects all live conductors, making it well suited to three-phase circuits\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity delivers the standard personal protection level against electric shock from earth fault currents\u003c\/li\u003e\n\u003cli\u003eType AC operation ensures detection of sinusoidal alternating residual fault currents\u003c\/li\u003e\n\u003cli\u003eStandard instantaneous trip characteristic from the F200 series, which also covers selective variants for tiered protection schemes\u003c\/li\u003e\n\u003cli\u003eAddresses a range of applications including special configurations supported across the broader F200 offer\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEarth fault protection in three-phase distribution boards and sub-panels\u003c\/li\u003e\n\u003cli\u003ePersonal and installation protection in commercial and light industrial premises\u003c\/li\u003e\n\u003cli\u003e4-pole residual current protection in circuits rated up to 40 A\u003c\/li\u003e\n\u003cli\u003eInstallations where sinusoidal alternating fault currents are the primary earth leakage risk\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F204 AC-40\/0.03, F204 AC-40\/0.03 2CSF204001R1400, ABB RCCB 4-pole 40A 30mA Type AC, residual current circuit breaker 40A 4P, ABB 2CSF204001R1400.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750014873864,"sku":"ABB2CSF204001R1400","price":47.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204001r1400-f204-ac-40003-residual-current-circuit-breaker-4p-ac-type-30-ma-344614.jpg?v=1735225740"},{"product_id":"2csf204001r1630-f204-ac-63-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204001R1630 F204 RCCB 4P 63A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB F204 AC-63\/0.03 (article 2CSF204001R1630) is a 4-pole Type AC residual current circuit breaker from the ABB F200 series, rated at 63 A with a trip sensitivity of 30 mA. It is built to guard people and electrical installations against fault currents flowing to earth, making it a direct fit for circuits where earth leakage protection is required.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F204 AC-63\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204001R1630\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542781400\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 63 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eOperating type: AC (sinusoidal alternating residual current)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole construction covers all live conductors and neutral in a single device, suited to three-phase installations\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity threshold provides personal protection against electric shock from earth fault currents\u003c\/li\u003e\n\u003cli\u003eType AC classification gives reliable trip response to sinusoidal alternating residual currents\u003c\/li\u003e\n\u003cli\u003ePart of the F200 range, which spans both standard instantaneous and selective trip variants as well as configurations for special applications\u003c\/li\u003e\n\u003cli\u003eProtects both people and connected equipment from the hazards of unintended earth fault paths\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEarth fault protection in residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eThree-phase circuits in offices, retail premises, and light industrial buildings\u003c\/li\u003e\n\u003cli\u003eSub-distribution panels requiring four-pole RCCB protection at 63 A\u003c\/li\u003e\n\u003cli\u003eInstallations where simultaneous protection of all phases plus neutral is mandatory\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F204 AC-63\/0.03, F204 AC-63\/0.03 2CSF204001R1630, ABB 4-pole RCCB 63 A 30 mA, ABB F200 series RCCB, residual current circuit breaker 2CSF204001R1630.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750014972168,"sku":"ABB2CSF204001R1630","price":66.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204001r1630-f204-ac-63003-residual-current-circuit-breaker-4p-ac-type-30-ma-719982.jpg?v=1735225732"},{"product_id":"2csf202001r0160-f202-ac-16-0-01-residual-current-circuit-breaker-2p-ac-type-10-ma","title":"ABB 2CSF202001R0160 F202 RCCB 2P 16A 10mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB F202 AC-16\/0.01 (article 2CSF202001R0160) is a 2-pole residual current circuit breaker (RCCB) from the F200 series, rated at 16 A with a residual current sensitivity of 10 mA and Type AC operation. It is designed to safeguard both people and electrical installations from dangerous fault currents flowing to earth. The 10 mA sensitivity level makes this device well suited to applications where a high degree of personal protection is needed.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F202 AC-16\/0.01\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202001R0160\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542779902\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current: 16 A\u003c\/li\u003e\n\u003cli\u003eRated residual operating current: 10 mA\u003c\/li\u003e\n\u003cli\u003eType: AC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProtects people and electrical installations against fault currents to earth, covering both personal safety and installation security\u003c\/li\u003e\n\u003cli\u003e10 mA residual current sensitivity delivers a high level of personal protection for circuits with elevated human contact risk\u003c\/li\u003e\n\u003cli\u003eType AC operation detects sinusoidal AC residual currents, the standard fault current form found in domestic and light commercial circuits\u003c\/li\u003e\n\u003cli\u003e2-pole configuration suits single-phase branch circuit protection in a compact form\u003c\/li\u003e\n\u003cli\u003ePart of the F200 series, which spans standard instantaneous and selective variants in AC and A types, plus configurations for special applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSocket outlet circuits in bathrooms, kitchens, and other locations with elevated risk of human contact with live conductors\u003c\/li\u003e\n\u003cli\u003eSingle-phase branch circuit protection in residential and light commercial buildings\u003c\/li\u003e\n\u003cli\u003eEarth leakage protection where sinusoidal AC fault currents represent the primary hazard\u003c\/li\u003e\n\u003cli\u003eAny installation requiring high-sensitivity personal protection against earth fault currents\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F202 AC-16\/0.01, F202 AC-16\/0.01 2CSF202001R0160, ABB RCCB 2P 16A 10mA Type AC, ABB earth leakage circuit breaker 16A, residual current device 10mA 16A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021296392,"sku":"ABB2CSF202001R0160","price":46.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202001r0160-f202-ac-16001-residual-current-circuit-breaker-2p-ac-type-10-ma-428311.jpg?v=1735325771"},{"product_id":"2csf202001r1250-f202-ac-25-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202001R1250 F202 RCCB 2P 25A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB F202 AC-25\/0.03 (article 2CSF202001R1250) is a 2-pole residual current circuit breaker (RCCB) from the F200 series, rated at 25 A with a 30 mA residual current trip threshold. It is designed to guard both people and electrical installations against fault currents flowing to earth, and responds to Type AC residual current.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F202 AC-25\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202001R1250\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542780007\u003c\/li\u003e\n\u003cli\u003eType: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 2P (2-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTrip type: Type AC\u003c\/li\u003e\n\u003cli\u003eProduct family: F200\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProvides protection for people and electrical installations against fault current flowing to earth, addressing both personal safety and equipment integrity.\u003c\/li\u003e\n\u003cli\u003eRated residual current of 30 mA defines the trip threshold, at which the device disconnects the circuit upon detecting earth leakage.\u003c\/li\u003e\n\u003cli\u003eType AC designation covers sensitivity to sinusoidal alternating residual currents, the type encountered in standard AC supply circuits.\u003c\/li\u003e\n\u003cli\u003e2-pole construction interrupts both live and neutral conductors in a single operation, suited to single-phase circuit protection.\u003c\/li\u003e\n\u003cli\u003ePart of the broader F200 range, which spans standard instantaneous and selective variants as well as configurations for special applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eProtection of socket-outlet and lighting circuits in homes and light commercial premises\u003c\/li\u003e\n\u003cli\u003eSingle-phase branch circuits requiring earth fault protection\u003c\/li\u003e\n\u003cli\u003eElectrical installations where protection of people against indirect contact is required\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F202 AC-25\/0.03, F202 AC-25\/0.03 2CSF202001R1250, ABB 2CSF202001R1250, RCCB 2-pole 25 A 30 mA Type AC, ABB F200 RCCB 25A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021329160,"sku":"ABB2CSF202001R1250","price":32.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202001r1250-f202-ac-25003-residual-current-circuit-breaker-2p-ac-type-30-ma-219635.jpg?v=1735225740"},{"product_id":"2csf202001r1400-f202-ac-40-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202001R1400 F202 RCCB 2P 40A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB F202 AC-40\/0.03 (article 2CSF202001R1400) is a 2-pole residual current circuit breaker from the ABB F200 series, rated at 40 A with a 30 mA trip sensitivity and Type AC residual current detection. It is designed to protect both people and electrical installations from fault current to earth, serving as a core safety device in single-phase distribution circuits.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: F202 AC-40\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202001R1400\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542780106\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eResidual current type: Type AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtects people and electrical installations against fault current to earth, combining personal safety and installation protection in a single device\u003c\/li\u003e\n\u003cli\u003e30 mA trip sensitivity provides earth fault detection at the level required for personal protection\u003c\/li\u003e\n\u003cli\u003e2-pole design isolates both conductors simultaneously on detection of a fault, appropriate for single-phase circuits\u003c\/li\u003e\n\u003cli\u003ePart of the wide F200 series offer, which spans standard instantaneous and selective variants across AC and A types to cover a broad range of installation requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePersonal protection on final circuits in residential consumer units and distribution boards\u003c\/li\u003e\n\u003cli\u003eEarth leakage protection for socket outlet and fixed equipment circuits\u003c\/li\u003e\n\u003cli\u003eSingle-phase circuits in light commercial and small industrial installations\u003c\/li\u003e\n\u003cli\u003eAny application calling for Type AC earth fault protection at up to 40 A rated current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB F202 AC-40\/0.03, F202 AC-40\/0.03 2CSF202001R1400, ABB RCCB 2-pole 40 A 30 mA, ABB residual current circuit breaker 40 A Type AC, F200 series RCCB 2P.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021361928,"sku":"ABB2CSF202001R1400","price":34.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202001r1400-f202-ac-40003-residual-current-circuit-breaker-2p-ac-type-30-ma-350485.png?v=1735225740"},{"product_id":"2csf202001r1630-f202-ac-63-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202001R1630 F202 RCCB 2P 63A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB F202 AC-63\/0.03 (article 2CSF202001R1630) is a 2-pole residual current circuit breaker (RCCB) from ABB's F200 series, rated at 63 A with a residual current sensitivity of 30 mA. It is built to protect both people and electrical installations against earth fault currents. The Type AC designation means it responds to sinusoidal alternating residual currents.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F202 AC-63\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202001R1630\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542780205\u003c\/li\u003e\n\u003cli\u003ePoles: 2P (2-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 63 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eResidual current type: Type AC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e30 mA tripping threshold offers personal protection against electric shock caused by earth fault currents\u003c\/li\u003e\n\u003cli\u003e63 A rated current accommodates higher-load single-phase circuits\u003c\/li\u003e\n\u003cli\u003e2-pole configuration suits single-phase distribution applications\u003c\/li\u003e\n\u003cli\u003eType AC detection responds to sinusoidal alternating residual currents as found in standard AC installations\u003c\/li\u003e\n\u003cli\u003ePart of the F200 series, which covers both instantaneous and selective variants as well as configurations for special applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eResidential and light commercial distribution boards requiring earth fault protection\u003c\/li\u003e\n\u003cli\u003eSingle-phase final circuits loaded up to 63 A\u003c\/li\u003e\n\u003cli\u003eInstallations where protection of people against indirect contact is required\u003c\/li\u003e\n\u003cli\u003eCircuits calling for Type AC residual current protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F202 AC-63\/0.03, F202 AC-63\/0.03 2CSF202001R1630, ABB 2CSF202001R1630, 2-pole RCCB 63 A 30 mA Type AC, ABB residual current circuit breaker 63A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021394696,"sku":"ABB2CSF202001R1630","price":54.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202001r1630-f202-ac-63003-residual-current-circuit-breaker-2p-ac-type-30-ma-868989.jpg?v=1735225739"},{"product_id":"2csf202004r1250-fh202-ac-25-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202004R1250 FH202 RCCB 2P 25A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB FH202 AC-25\/0.03 (article 2CSF202004R1250) is a 2-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 25 A with a 30 mA earth fault sensitivity. It detects fault currents flowing to earth and trips instantaneously to protect both people and electrical installations. This Type AC variant responds to sinusoidal alternating residual currents and is designed for standard domestic applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: FH202 AC-25\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202004R1250\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542893608\u003c\/li\u003e\n\u003cli\u003eType: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTrip characteristic: Type AC - standard instantaneous, sinusoidal AC residual current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30 mA sensitivity offers effective personal protection against earth leakage fault current\u003c\/li\u003e\n\u003cli\u003eInstantaneous tripping provides fast disconnection the moment a fault current to earth is detected\u003c\/li\u003e\n\u003cli\u003e2-pole design switches both live and neutral conductors in single-phase circuits\u003c\/li\u003e\n\u003cli\u003eType AC classification covers sinusoidal AC residual currents as found in standard domestic loads\u003c\/li\u003e\n\u003cli\u003ePart of the FH200 series, developed for domestic installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eSocket outlet and lighting circuits in homes and apartments\u003c\/li\u003e\n\u003cli\u003eBathroom, kitchen, and outdoor circuits where personal protection is required\u003c\/li\u003e\n\u003cli\u003eSingle-phase domestic wiring requiring earth fault protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB FH202 AC-25\/0.03, FH202 AC-25\/0.03 2CSF202004R1250, ABB RCCB 2P 25A 30mA Type AC, residual current circuit breaker 25A 30mA, ABB 2CSF202004R1250.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021427464,"sku":"ABB2CSF202004R1250","price":19.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202004r1250-fh202-ac-25003-residual-current-circuit-breaker-2p-ac-type-30-ma-336980.png?v=1735225732"},{"product_id":"2csf202004r1400-fh202-ac-40-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB FH202 2CSF202004R1400 RCCB 2P 40A 30mA Type AC","description":"\u003cp\u003eThe ABB FH202 AC-40\/0.03 (article 2CSF202004R1400) is a 2-pole residual current circuit breaker from the FH200 series, rated at 40 A with a 30 mA residual current trip threshold. It is built to guard people and electrical installations against earth fault currents, and is designed as a standard instantaneous Type AC device for domestic wiring applications.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: FH202 AC-40\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202004R1400\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542893707\u003c\/li\u003e\n\u003cli\u003eManufacturer: ABB\u003c\/li\u003e\n\u003cli\u003ePoles: 2P (2-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTripping type: AC (sinusoidal alternating residual currents)\u003c\/li\u003e\n\u003cli\u003eOperation: standard instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e30 mA trip threshold provides personal protection against indirect contact with live conductors\u003c\/li\u003e\n\u003cli\u003e2-pole format protects both line and neutral conductors on single-phase circuits\u003c\/li\u003e\n\u003cli\u003eType AC response covers sinusoidal AC earth fault currents, the standard requirement for most domestic circuits\u003c\/li\u003e\n\u003cli\u003eInstantaneous operation trips the circuit without intentional time delay on detection of a fault current\u003c\/li\u003e\n\u003cli\u003ePart of the broad FH200 family, sized and specified for installation in residential distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDomestic consumer units and distribution boards in homes and apartments\u003c\/li\u003e\n\u003cli\u003eSingle-phase final circuits requiring personal shock protection\u003c\/li\u003e\n\u003cli\u003eBathroom, kitchen, and utility room circuits where earth fault protection is mandatory\u003c\/li\u003e\n\u003cli\u003eGeneral residential wiring installations where a standard Type AC RCCB is specified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB FH202 AC-40\/0.03, FH202 AC-40\/0.03 2CSF202004R1400, ABB RCCB 40A 30mA 2-pole Type AC, residual current circuit breaker 40 A 30 mA, ABB earth leakage circuit breaker FH200.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021558536,"sku":"ABB2CSF202004R1400","price":21.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202004r1400-fh202-ac-40003-residual-current-circuit-breaker-2p-ac-type-30-ma-223431.png?v=1735225732"},{"product_id":"2csf202004r1630-fh202-ac-63-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202004R1630 FH202 RCCB 2P 63A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe ABB FH202 AC-63\/0.03 (article 2CSF202004R1630) is a 2-pole 63 A residual current circuit breaker from the ABB FH200 series, offering a 30 mA residual current sensitivity and a Type AC tripping characteristic. It is built to protect both people and electrical installations from earth fault currents. This RCCB is particularly suited to domestic wiring and distribution applications.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: FH202 AC-63\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202004R1630\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542893806\u003c\/li\u003e\n\u003cli\u003eDevice type: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current: 63 A\u003c\/li\u003e\n\u003cli\u003eResidual operating current: 30 mA\u003c\/li\u003e\n\u003cli\u003eTripping type: AC - instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e2-pole design disconnects both conductors on a fault, providing full isolation of the protected circuit\u003c\/li\u003e\n\u003cli\u003e30 mA residual operating current protects people against earth fault currents\u003c\/li\u003e\n\u003cli\u003e63 A rated current suits high-load final and sub-main circuit positions in domestic distribution boards\u003c\/li\u003e\n\u003cli\u003eInstantaneous Type AC tripping response addresses earth fault protection requirements in residential environments\u003c\/li\u003e\n\u003cli\u003ePart of the ABB FH200 series, designed specifically for domestic installation applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEarth fault protection in residential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eProtection of final circuits in domestic wiring installations\u003c\/li\u003e\n\u003cli\u003eSafeguarding people and installations against earth leakage in household electrical systems\u003c\/li\u003e\n\u003cli\u003eReplacement or upgrade of 2-pole 63 A Type AC RCCBs in domestic switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB FH202 AC-63\/0.03, FH202 AC-63\/0.03 2CSF202004R1630, ABB 2CSF202004R1630, ABB 63 A 30 mA 2-pole RCCB, ABB FH200 RCCB Type AC.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021591304,"sku":"ABB2CSF202004R1630","price":34.03,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202004r1630-fh202-ac-63003-residual-current-circuit-breaker-2p-ac-type-30-ma-913844.png?v=1735225733"},{"product_id":"2csr255080r1164-ds201-c16-ac30-residual-current-circuit-breaker-with-overcurrent-protection","title":"ABB 2CSR255080R1164 DS201 C16 AC30 RCBO 1P+N 16A 30mA Type AC","description":"\u003cp\u003eThe ABB DS201 C16 AC30 (article 2CSR255080R1164) is a 1P+N RCBO that combines overcurrent protection and residual current protection in a two-module wide unit. Rated at 16 A with a C tripping characteristic and 30 mA earth fault sensitivity, it defends single-phase end-user circuits against overload, short-circuit, and sinusoidal alternating earth fault currents.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: DS201 C16 AC30\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSR255080R1164\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542049210\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 16 A\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eResidual current type: AC (sinusoidal alternating)\u003c\/li\u003e\n\u003cli\u003eModule width: 2 modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates overcurrent and earth fault protection in one device, covering overload and short-circuit faults alongside residual current hazards\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity provides protection against indirect contact and additional protection against direct contact\u003c\/li\u003e\n\u003cli\u003eType AC operation detects sinusoidal alternating earth fault currents\u003c\/li\u003e\n\u003cli\u003e1P+N pole configuration protects both the live and neutral conductors of single-phase circuits\u003c\/li\u003e\n\u003cli\u003eTwo-module width keeps the device footprint compact within distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFinal circuits in residential and light-commercial single-phase distribution boards\u003c\/li\u003e\n\u003cli\u003eSocket outlet and lighting circuits requiring combined overcurrent and earth fault protection\u003c\/li\u003e\n\u003cli\u003eWet-area circuits such as bathrooms and kitchens where additional shock protection is needed\u003c\/li\u003e\n\u003cli\u003eSingle-phase circuits serving domestic appliances and consumer equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB DS201 C16 AC30, DS201 C16 AC30 2CSR255080R1164, ABB RCBO 16 A 30 mA Type AC, 1P+N RCBO 16 A C curve, ABB 2CSR255080R1164.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021689608,"sku":"ABB2CSR255080R1164","price":33.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csr255080r1164-ds201-c16-ac30-residual-current-circuit-breaker-with-overcurrent-protection-442715.png?v=1735225740"},{"product_id":"2csr255080r1254-ds201-c25-ac30-residual-current-circuit-breaker-with-overcurrent-protection","title":"2CSR255080R1254 ABB DS201 C25 AC30 RCBO 1P+N 25A 30mA Type AC","description":"\u003cp\u003eABB DS201 C25 AC30 (article 2CSR255080R1254) is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) rated at 25 A with a C trip characteristic and 30 mA residual current sensitivity. It fits in two module widths and provides combined protection for single-phase end-user circuits against overload, short-circuit, and sinusoidal alternating earth fault currents.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: DS201 C25 AC30\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSR255080R1254\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542049012\u003c\/li\u003e\n\u003cli\u003eConfiguration: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A\u003c\/li\u003e\n\u003cli\u003eTrip characteristic: C\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eResidual current type: Type AC (sinusoidal alternating)\u003c\/li\u003e\n\u003cli\u003eWidth: Two modules\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCombines overload and short-circuit protection with residual current protection in a single 1P+N device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity trips on sinusoidal alternating earth fault currents, guarding against indirect contact\u003c\/li\u003e\n\u003cli\u003eProvides additional protection against direct contact due to the 30 mA tripping threshold\u003c\/li\u003e\n\u003cli\u003eTwo-module width integrates MCB and RCD functions into a compact footprint in the distribution board\u003c\/li\u003e\n\u003cli\u003eType AC classification matches circuits where earth fault currents are sinusoidal in nature\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSingle-phase lighting and socket outlet circuits in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eEnd-user circuit protection in domestic and light commercial installations\u003c\/li\u003e\n\u003cli\u003eNew installations requiring combined overload, short-circuit, and residual current protection in one unit\u003c\/li\u003e\n\u003cli\u003eReplacement of separate MCB and RCD combinations where panel space is limited\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB DS201 C25 AC30, DS201 C25 AC30 2CSR255080R1254, ABB RCBO 25A 30mA Type AC, ABB 1P+N RCBO C25, ABB 2CSR255080R1254.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021722376,"sku":"ABB2CSR255080R1254","price":30.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csr255080r1254-ds201-c25-ac30-residual-current-circuit-breaker-with-overcurrent-protection-120052.png?v=1735225733"},{"product_id":"263577-pf7-25-2-003-de-residual-current-circuit-breaker-2p-25a-30ma-type-ac","title":"Eaton 263577 PF7-25\/2\/003-DE RCCB 2P 25 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF7-25\/2\/003-DE is a 2-pole Type AC RCCB from the Moeller xPole series, rated 25 A \/ 30 mA with a 10 kA Icn. Partly surge-proof to 250 A, it serves residential and commercial distribution installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF7-25\/2\/003-DE\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 263577\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082635770\u003c\/li\u003e\n  \u003cli\u003ePoles \/ leakage type: 2-pole, Type AC\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eFault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icn): 10 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC, 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +55 °C\u003c\/li\u003e\n  \u003cli\u003eStorage \/ transport temperature: -35 °C to +60 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width \/ depth: 2 SU (35 mm) \/ 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (IEC\/EN 60715), 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eTerminals: open-mouth lift, finger-safe per DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (flexible): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid-core): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eMax. back-up fuse: 25 A gG\/gL (overload) \/ 63 A (short-circuit)\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 - 250 V AC\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 2 W\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations; electrical: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping caused by transient overvoltages\u003c\/li\u003e\n  \u003cli\u003eWide ambient range -25 °C to +55 °C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eFinger- and touch-safe terminals per DGUV VS3 and EN 50274 improve installer safety\u003c\/li\u003e\n  \u003cli\u003eDIN-rail snap-on with 2 latch positions enables fast, secure panel assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidual current protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical installations requiring Type AC fault current detection\u003c\/li\u003e\n  \u003cli\u003eFinal circuits with 25 A rated current in domestic and light commercial premises\u003c\/li\u003e\n  \u003cli\u003ePanel assemblies where partial surge immunity limits nuisance disconnections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole series for residential and commercial switchgear.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF7-25\/2\/003-DE, Eaton 263577, Eaton catalog 263577, PF7 RCCB 25A 30mA.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44761458966792,"sku":"ETN263577","price":30.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/263577-pf7-252003-de-residual-current-circuit-breaker-2p-25a-30ma-type-ac-858957.jpg?v=1735225384"},{"product_id":"263584-pf7-25-4-003-de-residual-current-circuit-breaker-4p-25a-30ma-type-ac","title":"Eaton 263584 PF7-25\/4\/003-DE RCCB 4P 25 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF7-25\/4\/003-DE is a 4-pole Type AC RCCB from the Moeller xPole PF6\/7 series, designed for earth leakage protection in residential and commercial electrical installations. Rated at 25 A with a 30 mA fault current threshold and 10 kA short-time withstand current, it delivers reliable personnel and installation protection across 230 V AC and 400 V AC systems.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF7-25\/4\/003-DE\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 263584\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082635848\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eFault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: AC (Type AC)\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icn): 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: 250 A (partly surge-proof)\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 V AC - 440 V AC\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 70 mm (4 SU)\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 55 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (multi-wire): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation: 3.1 W\u003c\/li\u003e\n  \u003cli\u003eTerminal type: Open mouthed\/lift terminals, EN 50274, DGUV VS3\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC current sensitivity with partial surge protection to 250 A reduces nuisance tripping from transient currents\u003c\/li\u003e\n  \u003cli\u003eQuick 2-position DIN rail latching enables fast, tool-free panel assembly\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals rated to EN 50274 and DGUV VS3 for safe field wiring\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-FW\/LP 248296 remote control device for automated or remote switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial switchgear panels and office electrical installations\u003c\/li\u003e\n  \u003cli\u003eSocket outlet and final circuit earth leakage protection\u003c\/li\u003e\n  \u003cli\u003eSwitchgear assemblies requiring supplementary sealing with Z-RC\/AK-4TE 101062\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008, RoHS conform. Part of the Eaton Moeller xPole PF6\/7 RCCB series for residential and commercial switchgear applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF7-25\/4\/003-DE, Eaton 263584, Eaton catalog 263584, Eaton model PF7-25\/4\/003-DE, Eaton xPole 25 A 4-pole RCCB 30 mA Type AC.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44761459032328,"sku":"ETN263584","price":38.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/263584-pf7-254003-de-residual-current-circuit-breaker-4p-25a-30ma-type-ac-272492.jpg?v=1735225384"},{"product_id":"263586-pf7-40-4-003-de-residual-current-circuit-breaker-4p-40a-30ma-type-ac","title":"Eaton 263586 PF7-40\/4\/003-DE RCCB 4P 40 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF7-40\/4\/003-DE is a 4-pole Type AC RCCB from the Moeller series xPole range, rated at 40 A with a 30 mA residual current threshold. Offering a 10 kA short-time withstand current and partial surge immunity up to 250 A, it is designed for earth fault protection in residential and commercial distribution systems operating on 230 V AC \/ 400 V AC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF7-40\/4\/003-DE\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 263586\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082635862\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eRated residual current (IN): 30 mA, Type AC\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (ICW): 10 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, 4 SU (70 mm)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor, solid-core: 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor, multi-wired: 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eMaximum admissible back-up fuse: 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC detection responds to sinusoidal alternating residual currents for standard residential and commercial protection\u003c\/li\u003e\n  \u003cli\u003ePartial surge immunity rated at 250 A reduces nuisance tripping caused by transient currents\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail snap-fit with 2 latch positions for fast installation per IEC\/EN 60715\u003c\/li\u003e\n  \u003cli\u003eOpen mouthed\/lift terminals accept solid-core conductors up to 35 mm², enabling flexible wiring configurations\u003c\/li\u003e\n  \u003cli\u003eFinger and touch-safe terminal protection per EN 50274 and DGUV VS3 for safe on-site work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building main and sub-distribution panels\u003c\/li\u003e\n  \u003cli\u003eProtection of 3-phase and neutral circuits in 400 V AC systems\u003c\/li\u003e\n  \u003cli\u003eDIN rail panel assemblies with optional remote control via Z-FW\/LP 248296\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring surge-resistant residual current protection in mixed environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole PF7 RCCB range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF7-40\/4\/003-DE, Eaton 263586, Eaton catalog 263586, Eaton model PF7-40\/4\/003-DE, Eaton xPole 4-pole 40 A RCCB 30 mA Type AC.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44761459851528,"sku":"ETN263586","price":39.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/263586-pf7-404003-de-residual-current-circuit-breaker-4p-40a-30ma-type-ac-718791.jpg?v=1735225384"},{"product_id":"411005-dx-residual-current-circuit-breaker-1p-n-32a-30ma-230v-ac-type","title":"Legrand 411005 RCBO DX³ 6000 6kA 1P+N 230V~ 32A 30mA Type AC N right","description":"\u003cp\u003eThe Legrand 411005 is part of the DX³ LEGRAND RCBO range. RCBO DX³ 6000 10kA 1P+N 230V~ 32A 30mA Type AC N right.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 411005\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3245064110051\u003c\/li\u003e\n\u003cli\u003eproduct type: RCBO (Residual Current Circuit Breaker with Overcurrent protection)\u003c\/li\u003e\n\u003cli\u003enumber of poles total: 2\u003c\/li\u003e\n\u003cli\u003enumber of protected poles: 1\u003c\/li\u003e\n\u003cli\u003eRated voltage: 230 V\u003c\/li\u003e\n\u003cli\u003eRated current (In): 32 A\u003c\/li\u003e\n\u003cli\u003eRated residual current (IΔn): 0.03 A\u003c\/li\u003e\n\u003cli\u003eResidual current type: AC\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003erated short circuit breaking capacity iec 61009: 6 kA\u003c\/li\u003e\n\u003cli\u003erated short circuit breaking capacity iec 60947 2: 10 kA\u003c\/li\u003e\n\u003cli\u003eSurge current capacity: 0.25 kA\u003c\/li\u003e\n\u003cli\u003eVoltage type: AC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003erelease characteristic: C\u003c\/li\u003e\n\u003cli\u003econcurrently switching neutral: Yes\u003c\/li\u003e\n\u003cli\u003eInterlocking device: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003econnectable conductor solid core: 0.75-16 mm²\u003c\/li\u003e\n\u003cli\u003econnectable conductor multi wired: 0.75-10 mm²\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eneutral position: Right\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\u003cli\u003eManufactured by Legrand for professional electrical installations.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\u003cli\u003eProfessional electrical installations using the DX³ LEGRAND RCBO range.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 411005, 411005, DX³ LEGRAND RCBO.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":50221903708424,"sku":"LGR411005","price":35.47,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/411005-dx3-residual-current-circuit-breaker-1pn-32a-30ma-230v-ac-type-161004.jpg?v=1735226576"},{"product_id":"194690-eaton-hnc-25-2-003-residual-current-circuit-breaker-2p-25a-30ma-type-ac","title":"Eaton 194690 HNC-25\/2\/003 RCCB 2P 25 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton HNC-25\/2\/003 is a two-pole Type AC RCCB from the Eaton Moeller xPole Home series, providing personal protection against earth fault currents in residential and commercial installations. Rated at 25 A with a 30 mA fault current sensitivity and a 6 kA short-circuit rating, it delivers reliable protection on 230 V AC systems. The device mounts on a standard DIN rail and occupies 2 modular spacings (35 mm width).\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: HNC-25\/2\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 194690\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 9010238060623\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB, Type AC\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2 (two-pole)\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eRated fault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eShort-circuit rating (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping time: Non-delayed\u003c\/li\u003e\n  \u003cli\u003eSurge current capacity: 250 A\u003c\/li\u003e\n  \u003cli\u003eRated residual making and breaking capacity: 500 A\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 35 mm (2 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 45 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (H x W x D): 80 x 35 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.207 kg\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient temperature: -25 °C to +55 °C\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid-core): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (multi-wired): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eMax. back-up fuse: 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 2 W\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eColor: Gray (RAL 7035)\u003c\/li\u003e\n  \u003cli\u003eFitted with: Interlocking device\u003c\/li\u003e\n  \u003cli\u003eCertification: IEC\/EN 61008\u003c\/li\u003e\n  \u003cli\u003eRoHS: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensitivity detects sinusoidal alternating residual currents for broad earth fault coverage\u003c\/li\u003e\n  \u003cli\u003eNon-delayed tripping ensures immediate disconnection on fault detection\u003c\/li\u003e\n  \u003cli\u003eInterlocking device fitted as standard, enabling flexible panel assembly configurations\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25 °C to +55 °C) suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eCompact 2 SU DIN rail footprint minimises space requirements in consumer units\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof up to 250 A reduces nuisance tripping from transient currents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault protection in residential consumer units and home electrical panels\u003c\/li\u003e\n  \u003cli\u003eCommercial distribution boards and low-voltage switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003exPole Home residential switchgear systems\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, socket, and general-purpose circuits on 230 V AC networks\u003c\/li\u003e\n  \u003cli\u003eDIN rail panel builds requiring two-pole RCCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008 and RoHS requirements. Part of the Eaton Moeller xPole Home series for residential and commercial switchgear.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton HNC-25\/2\/003, Eaton 194690, Eaton catalog 194690, Eaton model HNC-25\/2\/003, Eaton xPole RCCB 25 A 30 mA 2-pole.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":51155124617480,"sku":"ETN194690","price":20.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/194690-eaton-hnc-252003-residual-current-circuit-breaker-2p-25a-30ma-type-ac-780562.jpg?v=1745820336"},{"product_id":"194691-eaton-hnc-40-2-003-residual-current-circuit-breaker-2p-40a-30ma-type-ac","title":"Eaton 194691 HNC-40\/2\/003 RCCB 2P 40 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton HNC-40\/2\/003 is a 2-pole Type AC RCCB from the Eaton Moeller xPole series, rated 40 A with a 30 mA residual fault current and 6 kA short-circuit strength. Designed for earth fault protection in residential and commercial installations, it mounts on DIN rail in a compact 2-module width.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: HNC-40\/2\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 194691\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 9010238060630\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB, Type AC, 2-pole\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eResidual fault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eShort-circuit strength (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eInsulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eResidual making\/breaking capacity: 500 A\u003c\/li\u003e\n  \u003cli\u003eSurge current capacity: 250 A (partly surge-proof)\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping time: Non-delayed\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, 2 SU (35 mm)\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.207 kg\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eConductor cross section: 1.5 - 35 mm² solid, 1.5 - 16 mm² stranded\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: max. 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation: 7.8 W\u003c\/li\u003e\n  \u003cli\u003eColor: Gray (RAL 7035)\u003c\/li\u003e\n  \u003cli\u003eFitted with: Interlocking device\u003c\/li\u003e\n  \u003cli\u003eCertification: IEC\/EN 61008\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensitivity for sinusoidal alternating fault currents, suited to residential and commercial loads\u003c\/li\u003e\n  \u003cli\u003eNon-delayed tripping for fast earth fault disconnection\u003c\/li\u003e\n  \u003cli\u003eCompact 2-module DIN rail footprint conserves space in consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eWide operating range of -25 °C to 60 °C for diverse installation environments\u003c\/li\u003e\n  \u003cli\u003eInterlocking device fitted as standard for coordination with adjacent switchgear\u003c\/li\u003e\n  \u003cli\u003eRoHS-compliant construction for environmentally responsible installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault protection in residential consumer units and domestic distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical panels requiring 30 mA personal protection\u003c\/li\u003e\n  \u003cli\u003exPole Home switchgear assemblies for apartment and housing developments\u003c\/li\u003e\n  \u003cli\u003eSocket outlet and lighting branch circuit protection\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring IEC\/EN 61008-compliant residual current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole Home series for residential and commercial switchgear.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton HNC-40\/2\/003, Eaton 194691, Eaton catalog 194691, Eaton model HNC-40\/2\/003, Eaton xPole RCCB 40 A 30 mA.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":51155126124808,"sku":"ETN194691","price":19.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/194691-eaton-hnc-402003-residual-current-circuit-breaker-2p-40a-30ma-type-ac-586657.jpg?v=1745820337"},{"product_id":"194694-eaton-hnc-40-4-003-residual-current-circuit-breaker-4p-40a-30ma-type-ac","title":"Eaton 194694 HNC-40\/4\/003 RCCB 4P 40 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton HNC-40\/4\/003 is a 4-pole RCCB from the Eaton Moeller xPole series, providing earth-fault protection in residential and commercial electrical installations. Rated at 40 A with a 30 mA trip threshold and 6 kA rated short-circuit strength, it delivers Type AC sensitivity for reliable detection of alternating sinusoidal residual currents. DIN rail mounting and a compact 4 SU width simplify integration into standard distribution boards.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: HNC-40\/4\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 194694\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 9010238060845\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eRated fault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: AC\u003c\/li\u003e\n  \u003cli\u003eRated short-circuit strength (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping time: Non-delayed\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 70 mm (4 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 45 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 70 mm x 80 mm x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.298 kg\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +60 °C\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (solid-core): 1.5 mm² to 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (multi-wired): 1.5 mm² to 16 mm²\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation: 13.1 W\u003c\/li\u003e\n  \u003cli\u003eRated residual making and breaking capacity: 500 A\u003c\/li\u003e\n  \u003cli\u003eSurge current capacity (impulse withstand): 250 A\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse (overload, max): 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 mm - 2 mm\u003c\/li\u003e\n  \u003cli\u003eColor: Gray (RAL 7035)\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensitivity detects alternating sinusoidal residual fault currents at a precise 30 mA threshold\u003c\/li\u003e\n  \u003cli\u003eNon-delayed tripping ensures fast disconnection to minimize electric shock risk\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof to 250 A impulse withstand current, reducing nuisance trips from transient surges\u003c\/li\u003e\n  \u003cli\u003eFitted with an interlocking device as standard; compatible with additional accessories for extended functionality\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 °C to +60 °C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eCompact 4 SU DIN rail footprint optimizes panel space in residential and commercial boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth-fault protection in residential consumer units and domestic distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial switchgear assemblies requiring IEC\/EN 61008 compliant residual current protection\u003c\/li\u003e\n  \u003cli\u003eFinal circuit protection within xPole Home residential switchgear systems\u003c\/li\u003e\n  \u003cli\u003e4-pole RCCB applications on 230\/400 V AC systems where Type AC sensitivity is specified\u003c\/li\u003e\n  \u003cli\u003eRetrofit and new-build installations in residential and light commercial premises\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole series for residential and commercial switchgear applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton HNC-40\/4\/003, Eaton 194694, Eaton catalog 194694, Eaton model HNC-40\/4\/003, Eaton xPole RCCB 40 A 4-pole 30 mA, Eaton Moeller HNC RCCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":51155126190344,"sku":"ETN194694","price":27.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/194694-eaton-hnc-404003-residual-current-circuit-breaker-4p-40a-30ma-type-ac-338207.jpg?v=1745820336"}],"url":"https:\/\/gabbyelectric.com\/en-us\/collections\/type-ac-rcd.oembed?page=3","provider":"Gabby Electric","version":"1.0","type":"link"}