Schneider A9F84106 Miniature Circuit Breaker (MCB), Acti9 iC60H 1P C6A 10kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F84106 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 6A with a C tripping characteristic. Designed for electrical distribution, it delivers a breaking capacity of 10,000A Icn at 230V AC and 15kA Icu at 220-240V AC, suitable for both AC and DC networks.
Technical specifications:
- Commercial reference: A9F84106
- Manufacturer: Schneider Electric
- Series / range: Acti 9 iC60
- Product type: Miniature Circuit Breaker (MCB)
- Short device name: iC60H
- Number of poles: 1P
- Number of protected poles: 1
- Rated current [In]: 6A
- Tripping curve: C
- Network type: AC / DC
- Protection unit technology: Thermomagnetic
- Breaking capacity: 10,000A Icn at 230V AC per EN/IEC 60898-1; 15kA Icu at 220-240V AC per EN/IEC 60947-2; 42kA Icu at 12-60V AC; 15kA Icu at 72V DC
- Service breaking capacity [Ics]: 7,500A (75%) at 230V AC per IEC 60898-1; 7.5kA (50%) at 220-240V AC per IEC 60947-2
- Limitation class: 3 per EN/IEC 60898-1
- Rated insulation voltage [Ui]: 500V AC per EN/IEC 60947-2
- Rated impulse withstand voltage [Uimp]: 6kV per EN/IEC 60947-2
- Overcurrent protection limit: 8 x In +/- 20%
- Overvoltage category: IV
- IP protection rating: IP20 per IEC/EN 60529
- Pollution degree: 3 per EN/IEC 60947-2
- Operating temperature: -35 to 70°C
- Storage temperature: -40 to 85°C
- Relative humidity: 95% at 55°C
- Width: 18mm
- Height: 85mm
- Depth: 78.5mm
- Product weight: 0.215kg
- Colour: White
- Mounting: DIN rail
- Connection: Single terminal block (upper or lower), 1-25mm² solid / 1-16mm² flexible
- Tightening torque: 2N.m
- Strip length: 14mm
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Standards: EN/IEC 60898-1, EN/IEC 60947-2
- Warranty: 18 months
Features and benefits:
- High breaking capacity of 10kA Icn at 230V AC ensures reliable short-circuit protection in demanding installations.
- Suitable for both AC and DC networks, providing flexibility across a wide range of applications.
- Thermomagnetic protection technology delivers precise overload and short-circuit tripping.
- Trip indicator provides clear local signalling of the breaker's tripped status.
- Compatible with comb busbar distribution blocks (upper or lower), simplifying panel wiring.
- Limitation class 3 minimises let-through energy, protecting downstream equipment.
Applications:
- Final distribution boards in residential and commercial buildings.
- Protection of lighting and socket circuits in low-voltage electrical panels.
- Industrial control panels requiring high breaking capacity in a compact 18mm-wide device.
- DC circuit protection in renewable energy or battery-backed systems.
- Sub-distribution boards where busbar connectivity and space optimisation are required.
Compliant with EN/IEC 60898-1 and EN/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F84106, Schneider Electric A9F84106, Acti9 iC60H C6A MCB, Schneider 6A C-curve miniature circuit breaker.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.