Schneider LADR4 Time Delay Auxiliary Contact Block, TeSys Deca, 1NO + 1NC, Off D
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric LADR4 is a TeSys Deca time delay auxiliary contact block, providing off-delay timer functionality with 1 NO + 1 NC contact configuration. It mounts to the front of TeSys Deca contactors and offers an adjustable off-delay range of 10 to 180 seconds for flexible timing control in motor and switching applications.
Technical specifications:
- Commercial reference: LADR4
- Manufacturer: Schneider Electric
- Series / range: TeSys Deca
- Product type: Time delay auxiliary contact block
- Contact configuration: 1 NO + 1 NC
- Timer type: Off-delay
- Time delay range: 10...180 s
- Rated operational voltage [Ue]: 690 V AC, 25...400 Hz
- Rated operational current [Ie]: 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
- Rated insulation voltage [Ui]: 690 V per IEC 60947-5-1; 600 V per UL and CSA
- Conventional thermal current [Ith]: 10 A at 60 °C
- Rated making capacity [Irms]: 140 A at 690 V AC; 250 A at 690 V DC
- Short-time withstand: 100 A / 1 s; 120 A / 500 ms; 140 A / 100 ms (all at 60 °C)
- Fuse protection: GG 10 A
- Mechanical endurance: 5 million operating cycles
- Minimum switching current: 5 mA
- Minimum switching voltage: 17 V
- Non-overlap time: 1.5 ms (both opening and closing)
- Insulation resistance: greater than 10 MOhm
- Connection type: Screw terminals, 1 or 2 cables, 1...2.5 mm² flexible or rigid
- Tightening torque: 1.7 N.m
- Mounting location: Front
- Dimensions (HxWxD): 48 x 44 x 61 mm
- Colour: Dark grey
- IP rating: IP20 per IEC 60529
- Operating temperature: -40...70 °C
- Storage temperature: -60...80 °C
- Operating altitude: up to 3000 m
- Standards: EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, EN 50012
- Certifications: IECEE CB Scheme, UL, CSA, CCC, EAC, UKCA
- Warranty: 18 months
Features and benefits:
- Adjustable off-delay timing from 10 to 180 seconds enables flexible sequencing of motor stops and control circuits
- Front-mounting design allows direct attachment to compatible TeSys Deca CAD and LC1D contactors without additional wiring
- Wide voltage range up to 690 V AC covers industrial three-phase applications across international markets
- 1.5 ms non-overlap time between NC and NO contacts prevents simultaneous contact closure during transition
- Screw terminal connections accept 1...2.5 mm² flexible and rigid cables for straightforward panel wiring
- Compliant with multiple international standards including IEC, UL, CSA, and CCC for global deployment
Applications:
- Motor control panels requiring timed off-delay sequences to allow controlled deceleration before circuit opens
- Industrial automation systems using TeSys Deca contactors where auxiliary timing functions are needed
- HVAC and refrigeration control circuits requiring delayed shutdown sequencing per IEC 60335-2-40 Annex JJ
- Machine control panels in manufacturing environments where off-delay logic prevents abrupt load disconnection
- Process automation switchgear assemblies in industrial facilities requiring certified auxiliary timing blocks
Compliant with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, and GB/T 14048.5. Part of the Schneider Electric TeSys Deca range.
Also known as: Schneider LADR4, Schneider Electric LADR4, TeSys D off-delay auxiliary contact block, time delay contactor auxiliary block.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.