The Schneider Electric A9K02325 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated at 25 A with a C tripping curve and 6 kA breaking capacity at 400 V AC. It uses thermomagnetic protection technology to guard three-phase AC circuits against overload and short-circuit faults, and is approved for use as an isolating device per EN/IEC 60898-1.
Technical specifications:
- Commercial reference: A9K02325
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 K60
- Number of poles: 3P
- Number of protected poles: 3
- Rated current (In): 25 A
- Network type: AC, 50/60 Hz
- Protection technology: Thermomagnetic
- Tripping curve: C
- Breaking capacity (Icn): 6000 A at 400 V AC 50/60 Hz
- Service breaking capacity (Ics): 6000 A (100%) at 400 V AC 50/60 Hz
- Rated isolation voltage (Ui): 440 V AC 50/60 Hz
- Rated impulse withstand voltage (Uimp): 4 kV
- Overcurrent protection range: 5...10 x In
- Limitation class: 3
- Mounting: DIN rail, fixed
- Dimensions (W x H x D): 54 x 81 x 70 mm
- Weight: 0.36 kg
- IP rating: IP20
- Operating temperature: -25...70°C
- Storage temperature: -40...70°C
- Connection terminals: Tunnel type, 0.5...35 mm² rigid / 0.5...25 mm² flexible (upper and lower)
- Tightening torque: 3.5 N.m
- Mechanical durability: 20,000 cycles
- Electrical durability: 10,000 cycles
- Certifications: OVE, VDE
- Standard: EN/IEC 60898-1
Features and benefits:
- Thermomagnetic trip unit provides both thermal overload and instantaneous magnetic short-circuit protection in a single device
- Ics equals 100% of Icn, delivering full-rated service breaking capacity without derating
- Approved for isolation duty per EN/IEC 60898-1, removing the need for a separate disconnector
- Compatible with comb busbars via double-connection lower terminals, simplifying three-phase distribution wiring
- Limitation class 3 minimises let-through energy, reducing thermal and mechanical stress on downstream equipment
- Wide operating range from -25 to 70°C suits both indoor distribution boards and more demanding industrial enclosures
Applications:
- Final distribution boards in commercial and industrial buildings
- Three-phase branch circuit protection in residential and tertiary electrical installations
- Industrial control panels and machine switchboards requiring thermomagnetic MCB protection
- Sub-distribution switchboards where isolation capability is required at the breaker
Compliant with EN/IEC 60898-1. Part of the Schneider Electric Acti 9 range.