Schneider A9F79206 Acti9 iC60N MCB 2P 6 A C Curve 10kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F79206 is a 2-pole miniature circuit breaker (MCB) from the Acti9 iC60N range, rated at 6 A with a C tripping curve. Designed for distribution applications, it delivers a breaking capacity of 10 kA at 380-415 V AC per IEC/EN 60947-2 and 6000 A at 400 V AC per IEC/EN 60898-1.
Technical specifications:
- Commercial reference: A9F79206
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti9 iC60
- Device short name: iC60N
- Number of poles: 2P
- Number of protected poles: 2
- Rated current: 6 A
- Tripping curve: C
- Trip unit technology: Thermal-magnetic
- Network type: AC / DC
- Rated operational voltage: 220-240 V AC, 380-415 V AC, 440 V AC, up to 125 V DC
- Breaking capacity: 10 kA Icu at 380-415 V AC (IEC/EN 60947-2); 6000 A Icn at 400 V AC (IEC/EN 60898-1)
- Magnetic tripping limit: 8 x In +/- 20%
- Rated insulation voltage: 500 V AC
- Rated impulse withstand voltage: 6 kV
- Utilisation category: Category A (IEC/EN 60947-2)
- Mounting: 35 mm DIN rail, clip-on
- Connection: Single terminal top or bottom, 1-25 mm² rigid or 1-16 mm² flexible copper
- Tightening torque: 2 N.m
- Width: 36 mm | Height: 85 mm | Depth: 78.5 mm
- Weight: 0.25 kg
- IP rating: IP20 (IEC 60529); IP40 in modular enclosure
- Operating temperature: -35 to 70 °C
- Operating altitude: 0-2000 m
- Pollution degree: 3
- Mechanical durability: 20000 cycles
- Electrical durability: 10000 cycles
- Standards: IEC/EN 60947-2, IEC/EN 60898-1
Features and benefits:
- Suitable for isolation per both IEC/EN 60898-1 and IEC/EN 60947-2
- Limitation class 3 for enhanced energy limitation and downstream equipment protection
- Compatible with top or bottom comb busbar connections at 18 mm phase pitch
- Trip indicator for fast visual fault detection without additional tools
- Wide operating temperature range (-35 to 70 °C) suitable for demanding environments
- PVC-free construction with recyclability potential of 54%
Applications:
- Final distribution boards in residential and commercial buildings
- Industrial control panels and machinery protection circuits
- DC distribution systems up to 125 V
- Sub-distribution boards requiring high breaking capacity at low current ratings
Compliant with IEC/EN 60947-2 and IEC/EN 60898-1. Part of the Schneider Electric Acti9 iC60 range.