Schneider A9F74350 Acti9 iC60N MCB 3P 50 A C Curve 10kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F74350 is a 3-pole 50 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed for electrical power distribution. It features a C tripping curve with a breaking capacity of 10 kA at 380-415 V AC, suitable for both AC and DC network types with thermomagnetic protection technology.
Technical specifications:
- Commercial reference: A9F74350
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Product type: Miniature circuit breaker (MCB)
- Short device name: iC60N
- Number of poles: 3P
- Number of protected poles: 3
- Rated current [In]: 50 A
- Tripping curve: C
- Network type: AC / DC
- Protection technology: Thermomagnetic
- Breaking capacity [Icn]: 6000 A at 400 V AC per EN/IEC 60898-1
- Breaking capacity [Icu]: 10 kA at 380-415 V AC per EN/IEC 60947-2
- Breaking capacity [Icu]: 10 kA at 125-180 V DC per EN/IEC 60947-2
- Service breaking capacity [Ics]: 7.5 kA (75%) at 380-415 V AC per IEC 60947-2
- Limitation class: 3
- Rated insulation voltage [Ui]: 500 V AC 50/60 Hz
- Rated impulse withstand voltage [Uimp]: 6 kV
- Overcurrent protection limit: 8 x In +/- 20%
- Width: 54 mm
- Height: 85 mm
- Depth: 78.5 mm
- Weight: 0.375 kg
- Color: White
- IP rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 85 °C
- Relative humidity: 95% at 55 °C
- Pollution degree: 3 per EN/IEC 60947-2
- Overvoltage category: IV
- Mounting: DIN rail
- Connection: Single terminal block (upper or lower), 1-35 mm² rigid / 1-25 mm² flexible
- Tightening torque: 3.5 N.m
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Standards: IEC 60898-1, EN 60898-1, EN 60947-2, IEC 60947-2
- Warranty: 18 months
Features and benefits:
- C tripping curve for standard distribution circuits with moderate inrush loads
- Suitable for both AC and DC network applications
- Contact position indicator and trip indicator for fast fault diagnosis
- Compatible with comb busbar distribution blocks (upper or lower)
- Tropicalized (class 2 per IEC 60068-1) for reliable operation in humid environments
- Suitable for isolation per EN/IEC 60898-1 and EN/IEC 60947-2
Applications:
- Final distribution boards in commercial and industrial buildings
- Protection of outgoing circuits in low-voltage switchboards
- DC distribution systems requiring certified MCB protection
- Industrial control panels and machine electrical panels
Compliant with IEC 60898-1, EN 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.