{"title":"3 Pole MCB","description":"\u003cp\u003ePower up with confidence using our \u003cstrong data-start=\"1057\" data-end=\"1071\"\u003e3 pole MCB\u003c\/strong\u003e selection. These \u003cstrong data-start=\"1089\" data-end=\"1108\"\u003e3 pole breakers\u003c\/strong\u003e are built to handle demanding electrical loads, offering superior protection against short circuits and overloads. Perfect for \u003cstrong data-start=\"1236\" data-end=\"1257\"\u003ethree-phase power\u003c\/strong\u003e systems in industrial and commercial environments, they combine compact design, high performance, and global safety certifications. Choose a \u003cstrong data-start=\"1399\" data-end=\"1418\"\u003e3 phase breaker\u003c\/strong\u003e that delivers lasting reliability and peace of mind.\u003c\/p\u003e","products":[{"product_id":"18637-miniature-circuit-breaker-mcb-acti9-ng125n-3p-40a-c-curve-25ka-iec-en-60947-2","title":"Schneider 18637 Miniature circuit breaker (MCB)","description":"\u003cp\u003eSchneider Electric 18637 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 NG125N range, rated at 40 A with a C tripping curve and a breaking capacity of 25 kA at 380-415 V AC per IEC 60947-2. Designed for electrical power distribution, it supports both AC and DC networks with thermomagnetic protection technology.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18637\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 NG125\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: NG125N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A at 40°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50 kA at 220-240 V AC; 25 kA at 380-415 V AC; 20 kA at 440 V AC; 10 kA at 500 V AC; 20 kA at up to 375 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 37.5 kA (220-240 V AC); 18.75 kA (380-415 V AC); 15 kA (440 V AC); 7.5 kA (500 V AC)\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 V \/ 380-415 V \/ 440 V \/ 500 V AC 50\/60 Hz; up to 375 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK protection: IK05 (EN\/IEC 62262)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, click-on\u003c\/li\u003e\n  \u003cli\u003eHandle position: Vertical\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel terminals 1.5-50 mm² (rigid); 1-35 mm² (flexible)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 20 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 103 x 81 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.72 kg\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eBusbar comb rail compatible: Yes (9 mm pitch)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 25 kA at 380-415 V AC suitable for demanding industrial and commercial installations\u003c\/li\u003e\n  \u003cli\u003eDual AC\/DC network compatibility provides flexibility across a wide range of electrical systems\u003c\/li\u003e\n  \u003cli\u003eIntegrated locking preparation allows the handle to be padlocked in the OFF position for safe isolation\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable quick visual status checks\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting and comb busbar compatibility simplify panel assembly\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-30 to 70°C) suits both indoor and harsh-environment enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in main distribution panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery storage installations\u003c\/li\u003e\n  \u003cli\u003eMotor and equipment protection in industrial automation panels\u003c\/li\u003e\n  \u003cli\u003eHigh-fault-level environments requiring elevated breaking capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18637, Schneider Electric 18637, Schneider NG125N 40A 3P MCB, Acti9 NG125N 40A circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065313718536,"sku":"SCH18637","price":92.21,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18637-miniature-circuit-breaker-mcb-acti9-ng125n-3p-40a-c-curve-25ka-iecen-60947-2-162200.jpg?v=1735224427"},{"product_id":"a9n18364-miniature-circuit-breaker-mcb-acti9-c120n-3p-63a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18364 Acti9 C120N MCB 3P 63 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18364 is the Acti 9 C120N 3-pole miniature circuit breaker (MCB) rated at 63 A with a C tripping curve, designed for electrical power distribution. It delivers a breaking capacity of 10 kA Icn at 230...400 V AC per EN\/IEC 60898-1, with a thermomagnetic protection unit providing reliable overcurrent and short-circuit protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18364\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 63 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 230...400 V AC \/ up to 440 V AC \/ up to 375 V DC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10 kA at 230...400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 20 kA at 220...240 V AC, 10 kA at 380...415 V AC, 6 kA at 440 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm symmetric DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 1...50 mm² rigid \/ 1.5...35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.615 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per IEC 60947-2, enabling safe maintenance disconnection\u003c\/li\u003e\n  \u003cli\u003eHandle sealable in ON or OFF position for tamper-evident installations\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbars for efficient wiring in distribution boards\u003c\/li\u003e\n  \u003cli\u003eCovers both AC and DC networks, rated up to 440 V AC and 375 V DC\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV, suitable for use at the origin of the electrical installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThree-phase distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection for three-phase sub-circuits at 63 A\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high breaking capacity at 10 kA\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring isolation capability with sealed handle security\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18364, Schneider Electric A9N18364, C120N 3P 63A MCB, Acti9 C120N circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065331380488,"sku":"SCHA9N18364","price":62.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18364-miniature-circuit-breaker-mcb-acti9-c120n-3p-63a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-706526.jpg?v=1735231069"},{"product_id":"a9n18365-miniature-circuit-breaker-mcb-acti9-c120n-3p-80a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18365 Acti9 C120N MCB 3P 80 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18365 is a 3-pole 80 A miniature circuit breaker (MCB) from the Acti 9 C120N series, designed for electrical power distribution. It features a type C tripping curve and thermomagnetic protection, with a breaking capacity of 10 kA Icn at 230...400 V AC per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18365\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 80 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 230...400 V AC, 440 V AC, 220...240 V AC, up to 375 V DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10 kA at 230...400 V AC (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220...240 V AC, 10 kA at 380...415 V AC, 6 kA at 440 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, snap-on\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals 1...50 mm² rigid \/ 1.5...35 mm² flexible; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.615 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection delivers reliable overcurrent and short-circuit defence\u003c\/li\u003e\n  \u003cli\u003eHandle sealable with 0.7 mm cable in ON or OFF position for tamper resistance\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for fast DIN rail panel assembly\u003c\/li\u003e\n  \u003cli\u003eWide cable acceptance (1...50 mm² rigid, 1.5...35 mm² flexible) suits varied wiring\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolator per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in low-voltage distribution panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels with high short-circuit current requirements\u003c\/li\u003e\n  \u003cli\u003eMixed AC and DC network installations requiring overvoltage category IV protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18365, Schneider Electric A9N18365, C120N 3P 80A MCB, Acti9 C120N circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065331413256,"sku":"SCHA9N18365","price":96.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18365-miniature-circuit-breaker-mcb-acti9-c120n-3p-80a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-886409.jpg?v=1735231075"},{"product_id":"a9n18367-miniature-circuit-breaker-mcb-acti9-c120n-3p-100a-c-curve-10000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9N18367 Acti9 C120N MCB 3P 100 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18367 is a 3-pole 100 A miniature circuit breaker (MCB) from the Acti 9 C120N range, featuring a C tripping curve and thermomagnetic protection technology. Designed for electrical energy distribution, it delivers a breaking capacity of 10,000 A Icn at 230-400 V AC per EN\/IEC 60898-1, suitable for commercial and industrial panel installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18367\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 100 A at 30°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10,000 A at 230-400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC \/ 10 kA at 380-415 V AC \/ 6 kA at 440 V AC \/ 10 kA at \u0026lt;=375 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, click-fit\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 81 x 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.615 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals 1-50 mm² solid \/ 1.5-35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eCertification: EAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per IEC 60947-2, enabling safe disconnection of circuits\u003c\/li\u003e\n  \u003cli\u003eHandle sealable in OFF or ON position with 0.7 mm cable to prevent unauthorized switching\u003c\/li\u003e\n  \u003cli\u003eCompatible with busbar comb distribution blocks for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator with ON\/OFF local readout for clear circuit status monitoring\u003c\/li\u003e\n  \u003cli\u003eOperable up to 2000 m altitude and 95% relative humidity at 55°C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance 20,000 cycles; electrical endurance 5,000 cycles per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in low-voltage switchboards\u003c\/li\u003e\n  \u003cli\u003eThree-phase distribution panels requiring 100 A overcurrent and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring safe isolation capability within panel assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2 and EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18367, Schneider Electric A9N18367, C120N 3P 100A MCB, Acti9 C120N circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065331478792,"sku":"SCHA9N18367","price":99.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18367-miniature-circuit-breaker-mcb-acti9-c120n-3p-100a-c-curve-10000a-iecen-60898-1-10ka-iecen-60947-2-466654.jpg?v=1735231075"},{"product_id":"a9f73302-miniature-circuit-breaker-mcb-acti9-ic60n-3p-2a-b-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F73302 Acti9 iC60N MCB 3P 2 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73302 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 2 A with a B tripping curve for electrical energy distribution on AC and DC networks. Thermomagnetic protection technology guards against both overload and short-circuit conditions. Breaking capacity is 6000 A Icn at 400 V AC per IEC 60898-1, rising to 50 kA Icu at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73302\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current: 2 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 25 kA at 440 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 50 kA 100% at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eTropicalization: Class 2 per IEC 60068-1\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (upper or lower), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm; tightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block: Compatible, upper or lower\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve provides overcurrent protection suited to circuits with low starting currents\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN 60898-1 and EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eTrip indicator enables local fault signaling without additional instrumentation\u003c\/li\u003e\n  \u003cli\u003eTropicalized construction (Class 2 per IEC 60068-1) for reliable operation in demanding environments\u003c\/li\u003e\n  \u003cli\u003eHigh mechanical durability rated at 20,000 operating cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards for electrical energy distribution in residential and commercial installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial switchgear panels requiring 3-pole B-curve overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection up to 180 V in low-voltage DC distribution systems\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounted assemblies with comb busbar connectivity\u003c\/li\u003e\n  \u003cli\u003eControl panels requiring an isolating-rated MCB per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73302, Schneider Electric A9F73302, iC60N 3P 2A B curve MCB, Acti9 miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065506590984,"sku":"SCHA9F73302","price":18.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73302-miniature-circuit-breaker-mcb-acti9-ic60n-3p-2a-b-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-766411.jpg?v=1735230354"},{"product_id":"a9f73304-miniature-circuit-breaker-mcb-acti9-ic60n-3p-4a-b-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F73304 Acti9 iC60N MCB 3P 4 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73304 is a 3-pole 4 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, featuring a B tripping curve and thermomagnetic protection technology. Compatible with both AC and DC networks, it delivers a breaking capacity of 6,000 A Icn at 400 V AC per IEC 60898-1 and up to 50 kA Icu at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73304\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 4 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 380-415 V AC, 25 kA at 440 V AC, 10 kA at up to 180 V DC per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eUtilization category: Category A per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible, tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic trip unit provides reliable protection against overloads and short circuits\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks, upper or lower connection, 9 mm pitch\u003c\/li\u003e\n  \u003cli\u003eLocal trip indicator enables fast visual fault identification\u003c\/li\u003e\n  \u003cli\u003eHigh durability with 20,000 mechanical cycles and 10,000 electrical cycles\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks for versatile panel installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDC power distribution systems up to 180 V\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring overvoltage category IV and pollution degree 3 compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73304, Schneider Electric A9F73304, Acti9 iC60N 4A B curve MCB, 3-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065507377416,"sku":"SCHA9F73304","price":16.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73304-miniature-circuit-breaker-mcb-acti9-ic60n-3p-4a-b-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-411341.jpg?v=1735230354"},{"product_id":"a9f73306-miniature-circuit-breaker-mcb-acti9-ic60n-3p-6a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73306 Acti9 iC60N MCB 3P 6 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73306 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 6 A with a B tripping curve. Designed for electrical power distribution, it provides thermomagnetic overcurrent protection with a breaking capacity of 10 kA at 380-415 V AC, making it suitable for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73306\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort designation: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, IEC 60898-1, EN 60947-2, EN 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection technology ensures reliable overcurrent and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eB tripping curve optimised for circuits with low inrush current loads such as resistive and lighting applications\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable quick visual status verification\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-35 to 70 °C) and tropicalisation class 2 for demanding environments\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation duty per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and resistive loads in electrical panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring AC or DC circuit protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage power distribution switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, IEC 60898-1, EN 60947-2, and EN 60898-1. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73306, Schneider Electric A9F73306, iC60N 3P 6A B curve MCB, Acti9 miniature circuit breaker 6A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065507508488,"sku":"SCHA9F73306","price":13.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73306-miniature-circuit-breaker-mcb-acti9-ic60n-3p-6a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-470074.jpg?v=1735230354"},{"product_id":"a9f73310-ic60n-miniature-circuit-breaker-3p-10a-b-curve","title":"Schneider A9F73310 Acti9 iC60N MCB 3P 10 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73310 is a 3-pole, 10 A Miniature Circuit Breaker (MCB) from the Acti 9 iC60N series, designed for electrical power distribution. Featuring a B tripping curve and thermomagnetic protection technology, it delivers a breaking capacity of 10 kA at 380-415 V AC and supports both AC and DC network applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73310\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC; 20 kA at 220-240 V AC; 10 kA at up to 180 V DC (per EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 380-415 V AC; 15 kA at 220-240 V AC (per EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm; Tightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection unit for reliable response to both overload and short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eB tripping curve suitable for sensitive loads requiring earlier magnetic trip activation\u003c\/li\u003e\n  \u003cli\u003eCompatible with upper or lower comb busbar distribution blocks for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for rapid local fault identification\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and sensitive low-power loads\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring DC circuit protection\u003c\/li\u003e\n  \u003cli\u003eElectrical distribution systems where B-curve tripping characteristics are specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73310, Schneider Electric A9F73310, iC60N 3P 10A B curve MCB, Acti9 miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065508163848,"sku":"SCHA9F73310","price":11.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73310-ic60n-miniature-circuit-breaker-3p-10a-b-curve-392107.jpg?v=1735230349"},{"product_id":"a9f73316-miniature-circuit-breaker-mcb-acti9-ic60n-3p-16a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73316 Acti9 iC60N MCB 3P 16 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73316 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 16 A with a B tripping curve. Designed for electrical power distribution, it provides thermomagnetic protection for both AC and DC networks, with a breaking capacity of 10 kA at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73316\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 125-180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA (75%) at 380-415 V AC per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eProduct weight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2, enabling safe disconnection of circuits\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks from top or bottom, simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eTrip position indicator and trip flag provide clear local signalling of fault events\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 ensures fast current limitation, reducing thermal and mechanical stress on downstream equipment\u003c\/li\u003e\n  \u003cli\u003eOperates across a wide temperature range (-35 to 70 °C), suitable for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring thermomagnetic overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eDC and AC mixed-network installations requiring versatile circuit protection\u003c\/li\u003e\n  \u003cli\u003eMotor and equipment branch circuit protection in light industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73316, Schneider Electric A9F73316, iC60N 3P 16A B curve MCB, Acti9 miniature circuit breaker 16A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065508262152,"sku":"SCHA9F73316","price":11.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73316-miniature-circuit-breaker-mcb-acti9-ic60n-3p-16a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-299015.jpg?v=1735230350"},{"product_id":"a9f73320-miniature-circuit-breaker-mcb-acti9-ic60n-3p-20a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73320 Acti9 iC60N MCB 3P 20 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73320 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 20 A with a B tripping curve. It provides thermomagnetic overcurrent protection for both AC and DC networks, with a breaking capacity of 10 kA at 380-415 V AC (IEC 60947-2).\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73320\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC 50\/60 Hz (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC 50\/60 Hz (EN\/IEC 60947-2); 20 kA Icu at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2); 10 kA Icu at up to 180 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block (top or bottom), 1-25 mm² solid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB curve tripping characteristic suited for circuits with low inrush currents, providing sensitive protection against overloads and short circuits\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for flexible installation in diverse distribution systems\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for fast visual diagnostics\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eColor: white; designed for fixed installation on standard DIN rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and low-inrush electrical loads\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and DC distribution systems\u003c\/li\u003e\n  \u003cli\u003eSwitchboards requiring compact 3-pole overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73320, Schneider Electric A9F73320, Acti9 iC60N 3P 20A B curve MCB, Schneider 3-pole miniature circuit breaker 20A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065508327688,"sku":"SCHA9F73320","price":11.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73320-miniature-circuit-breaker-mcb-acti9-ic60n-3p-20a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-255846.jpg?v=1735230349"},{"product_id":"a9f73325-miniature-circuit-breaker-mcb-acti9-ic60n-3p-25a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73325 Acti9 iC60N MCB 3P 25 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73325 is a 3-pole, 25 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed for electrical power distribution on AC and DC networks. It uses thermomagnetic protection with a B tripping curve and provides a rated breaking capacity of 6,000 A Icn at 400 V AC per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73325\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 25 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380...415 V AC \/ 20 kA at 220...240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1...25 mm² rigid \/ 1...16 mm² flexible; strip length 14 mm; torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB curve thermomagnetic protection with overcurrent trip threshold at 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for versatile distribution panel design\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with support for upper or lower comb busbar distribution blocks\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for immediate local fault signalization\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 per EN\/IEC 60898-1 limits energy let-through during fault conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring circuit protection on AC or DC networks\u003c\/li\u003e\n  \u003cli\u003ePower distribution systems where a B tripping characteristic is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73325, Schneider Electric A9F73325, iC60N 3P 25A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065509835016,"sku":"SCHA9F73325","price":13.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73325-miniature-circuit-breaker-mcb-acti9-ic60n-3p-25a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-723721.jpg?v=1735230349"},{"product_id":"a9f73332-miniature-circuit-breaker-mcb-acti9-ic60n-3p-32a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73332 Acti9 iC60N MCB 3P 32 A B Curve 10kA","description":"\u003cp\u003eThe A9F73332 is a Schneider Electric Acti 9 iC60N 3-pole 32 A miniature circuit breaker with a B tripping curve, designed for overcurrent and short-circuit protection in AC and DC electrical distribution systems. It delivers a breaking capacity of 10 kA at 380-415 V AC per IEC\/EN 60947-2, with a thermomagnetic protection unit ensuring precise trip response.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73332\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 32 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 380-415 V AC; 20 kA at 220-240 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV, pollution degree: 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve provides sensitive short-circuit protection suited to circuits with low inrush currents\u003c\/li\u003e\n  \u003cli\u003eUsage category A per IEC\/EN 60947-2, with full isolation rating per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator enables immediate local fault signaling\u003c\/li\u003e\n  \u003cli\u003eCompatible with upper or lower comb busbar connection for faster panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and light industrial installations\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, heating, and other low-inrush circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and DC network protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73332, Schneider Electric A9F73332, iC60N 3-pole 32A MCB, Acti 9 miniature circuit breaker 32A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065509900552,"sku":"SCHA9F73332","price":14.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73332-miniature-circuit-breaker-mcb-acti9-ic60n-3p-32a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-930421.jpg?v=1735230357"},{"product_id":"a9f73340-miniature-circuit-breaker-mcb-acti9-ic60n-3p-40a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73340 Acti9 iC60N MCB 3P 40 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73340 is a 3-pole 40 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical energy distribution applications. With a B tripping curve and thermomagnetic protection technology, it delivers a breaking capacity of 10 kA at 380-415 V AC and is rated for both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73340\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 40 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC per EN\/IEC 60898-1; 10 kA Icu at 380-415 V AC per EN\/IEC 60947-2; 10 kA Icu at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2, enabling safe maintenance procedures\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for immediate local fault identification\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C with tropicalization grade 2 for humid environments up to 95% relative humidity at 55°C\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV for installation at the origin of electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and resistive load circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and general electrical distribution systems\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in low-voltage distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73340, Schneider Electric A9F73340, iC60N 3P 40A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065510686984,"sku":"SCHA9F73340","price":18.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73340-miniature-circuit-breaker-mcb-acti9-ic60n-3p-40a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-965560.jpg?v=1735230350"},{"product_id":"a9f73350-miniature-circuit-breaker-mcb-acti9-ic60n-3p-50a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73350 Acti9 iC60N MCB 3P 50 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73350 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 50 A with a B tripping curve for overload and short-circuit protection in electrical distribution systems. It supports both AC and DC networks and delivers a breaking capacity of 10 kA Icu at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73350\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 50 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC per EN\/IEC 60898-1; 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC; 10 kA Icu at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB tripping curve for early tripping, suited to sensitive loads and long cable runs\u003c\/li\u003e\n  \u003cli\u003eThermomagnetic protection unit for combined thermal and magnetic trip response\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for fast local identification of a tripped state\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003e20,000 mechanical cycles and 10,000 electrical cycles endurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eLow-voltage distribution panels requiring overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial control cabinets and machinery protection circuits\u003c\/li\u003e\n  \u003cli\u003eDC network applications such as photovoltaic or battery-backed systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73350, Schneider Electric A9F73350, iC60N 3P 50A B curve MCB, Acti9 miniature circuit breaker 50A 3 pole.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065510785288,"sku":"SCHA9F73350","price":25.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73350-miniature-circuit-breaker-mcb-acti9-ic60n-3p-50a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-823939.jpg?v=1735230357"},{"product_id":"a9f73363-miniature-circuit-breaker-mcb-acti9-ic60n-3p-63a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73363 Acti9 iC60N MCB 3P 63 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73363 is a 3-pole, 63 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, providing thermomagnetic overcurrent and short-circuit protection in AC and DC distribution systems. Its B tripping curve and 10 kA breaking capacity at 380-415 V AC suit a wide range of low-voltage panel applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73363\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current: 63 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible; strip length 14 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMagnetic overcurrent trip threshold at 4 x In +\/- 20% for precise cable protection\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable fast fault diagnosis without panel opening\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on top or bottom terminals\u003c\/li\u003e\n  \u003cli\u003eHigh endurance rated at 20,000 mechanical cycles and 10,000 electrical cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eCable and conductor protection in low-voltage switchgear panels\u003c\/li\u003e\n  \u003cli\u003eDC distribution circuits requiring thermomagnetic circuit protection\u003c\/li\u003e\n  \u003cli\u003eLight industrial equipment and motor branch circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73363, Schneider Electric A9F73363, iC60N 3P 63A MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065510850824,"sku":"SCHA9F73363","price":31.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73363-miniature-circuit-breaker-mcb-acti9-ic60n-3p-63a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-429475.jpg?v=1735230351"},{"product_id":"a9f74302-miniature-circuit-breaker-mcb-acti9-ic60n-3p-2a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74302 Acti9 iC60N MCB 3P 2 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74302 is an Acti 9 iC60N 3-pole miniature circuit breaker (MCB) rated at 2 A with a C tripping curve, designed for overcurrent protection in AC and DC low-voltage distribution systems. It delivers a breaking capacity of 6,000 A Icn at 400 V AC per IEC 60898-1 and up to 50 kA Icu at 380-415 V AC per IEC 60947-2, combining high performance with a compact DIN rail footprint.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74302\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 2 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 380-415 V AC, 25 kA at 440 V AC, 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 50 kA (100%) at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eUtilization category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (fixed)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eQuality mark: NF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator provides local fault signaling\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 ensures high energy limitation for downstream component protection\u003c\/li\u003e\n  \u003cli\u003eOperates on both AC and DC networks\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 and overvoltage category IV rating for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent protection in final distribution boards for residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial electrical panels and low-voltage switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eCable and equipment protection in building services installations\u003c\/li\u003e\n  \u003cli\u003eAC and DC distribution systems requiring high breaking capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74302, Schneider Electric A9F74302, iC60N 3P 2A C curve MCB, Acti9 miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515634952,"sku":"SCHA9F74302","price":19.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74302-miniature-circuit-breaker-mcb-acti9-ic60n-3p-2a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-719809.jpg?v=1735230426"},{"product_id":"a9f74304-miniature-circuit-breaker-mcb-acti9-ic60n-3p-4a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74304 Acti9 iC60N MCB 3P 4 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74304 is a 3-pole 4 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, fitted with a C tripping curve and thermomagnetic protection. It operates on both AC and DC networks with a breaking capacity of 50 kA Icu at 380-415 V AC per IEC\/EN 60947-2, making it a high-performance choice for demanding distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74304\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 4 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6,000 A Icn at 400 V AC (IEC\/EN 60898-1); 50 kA Icu at 380-415 V AC (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 50 kA (100%) at 380-415 V AC per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible: Yes (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection suitable for both AC and DC distribution systems\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity of 50 kA Icu at 380-415 V AC for robust short-circuit protection in high-demand installations\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises peak let-through current, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable fast visual status checks\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for flexible, space-efficient panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial switchgear assemblies and control panels\u003c\/li\u003e\n  \u003cli\u003eDC and mixed AC\/DC power distribution systems\u003c\/li\u003e\n  \u003cli\u003eCable and circuit protection where high breaking capacity is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74304, Schneider Electric A9F74304, iC60N 3-pole MCB 4A, Acti9 miniature circuit breaker C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516421384,"sku":"SCHA9F74304","price":18.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74304-miniature-circuit-breaker-mcb-acti9-ic60n-3p-4a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-100258.jpg?v=1735230425"},{"product_id":"a9f74306-ic60n-miniature-circuit-breaker-3p-6a-c-curve","title":"Schneider A9F74306 Acti9 iC60N MCB 3P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74306 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 6 A with a C tripping curve. Designed for AC and DC power distribution networks, it delivers thermomagnetic overcurrent and short-circuit protection with a breaking capacity of 10 kA Icu at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74306\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible conductor\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection for reliable response to both overload and short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eC tripping curve suited for loads with moderate inrush currents such as lighting and general wiring\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for quick local fault identification\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 and overvoltage category IV rating for demanding installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial power distribution and control panels\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and socket outlet circuits\u003c\/li\u003e\n  \u003cli\u003eAutomation and switchgear panel protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74306, Schneider Electric A9F74306, iC60N 3P 6A C curve MCB, Acti9 3-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516519688,"sku":"SCHA9F74306","price":12.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74306-ic60n-miniature-circuit-breaker-3p-6a-c-curve-460798.jpg?v=1735230426"},{"product_id":"a9f74310-miniature-circuit-breaker-mcb-acti9-ic60n-3p-10a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74310 Acti9 iC60N MCB 3P 10 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74310 is a 3-pole 10 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, providing overcurrent and short-circuit protection for AC and DC distribution systems. Equipped with a C tripping curve and thermomagnetic protection technology, it delivers a breaking capacity of 10 kA at 380-415 V AC per IEC 60947-2 and 6000 A Icn at 400 V AC per IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74310\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 380-415 V AC 50\/60 Hz per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, IEC 60898-1, EN 60947-2, EN 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection provides reliable response to both overload and short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eC tripping curve with overcurrent limit at 8 x In, suited to loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eCompatible with upper or lower comb busbar distribution blocks for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eTrip indicator gives immediate local signaling of fault conditions\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, including DC applications up to 180 V\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 rating supports use in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of resistive and moderately inductive loads in switchboards and panel assemblies\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and machine protection circuits\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems requiring IEC 60947-2 rated protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, IEC 60898-1, EN 60947-2, and EN 60898-1. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74310, Schneider Electric A9F74310, iC60N 3P 10A C curve MCB, Acti 9 miniature circuit breaker 3 pole 10 A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516617992,"sku":"SCHA9F74310","price":11.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74310-miniature-circuit-breaker-mcb-acti9-ic60n-3p-10a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-855772.jpg?v=1735230418"},{"product_id":"a9f74313-miniature-circuit-breaker-mcb-acti9-ic60n-3p-13a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74313 Acti9 iC60N MCB 3P 13 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74313 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 13 A with a C tripping curve. It provides thermomagnetic overload and short-circuit protection for AC and DC distribution networks, with a breaking capacity of 10 kA at 380-415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74313\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 13 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC per EN\/IEC 60898-1; 10 kA Icu at 380-415 V AC per EN\/IEC 60947-2; 20 kA Icu at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles; electrical durability: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection with overcurrent trip threshold at 8 x In (+\/- 20%)\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator and contact position indicator for fast fault identification\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 per IEC 60068-1, rated for 95% relative humidity at 55°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eOutgoing circuit protection in main and sub-distribution panels\u003c\/li\u003e\n  \u003cli\u003eMotor and equipment circuit protection in automation and control panel assemblies\u003c\/li\u003e\n  \u003cli\u003eAC and DC distribution systems requiring compact DIN rail-mounted overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, EN 60947-2, IEC 60898-1, and EN 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74313, Schneider Electric A9F74313, Acti9 iC60N 3-pole MCB 13A C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516650760,"sku":"SCHA9F74313","price":10.12,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74313-miniature-circuit-breaker-mcb-acti9-ic60n-3p-13a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-253835.jpg?v=1735230419"},{"product_id":"a9f74316-ic60n-miniature-circuit-breaker-3p-16a-c-curve","title":"Schneider A9F74316 Acti9 iC60N MCB 3P 16 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74316 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 16 A with a C tripping curve. Designed for electrical power distribution, it provides reliable overcurrent protection with a breaking capacity of 10 kA at 380-415 V AC, suitable for both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74316\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95 % at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve provides reliable protection for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for versatile installation\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block connection available from top or bottom terminals\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for fast fault diagnosis\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70 °C for demanding environments\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of branch circuits in electrical panels and switchboards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring AC and DC circuit protection\u003c\/li\u003e\n  \u003cli\u003ePower distribution systems with comb busbar arrangements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74316, Schneider Electric A9F74316, Schneider iC60N 3P 16A MCB, Acti9 miniature circuit breaker C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516716296,"sku":"SCHA9F74316","price":10.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74316-ic60n-miniature-circuit-breaker-3p-16a-c-curve-757964.jpg?v=1735230426"},{"product_id":"a9f74320-ic60n-miniature-circuit-breaker-3p-20a-c-curve","title":"Schneider A9F74320 Acti9 iC60N MCB 3P 20 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74320 is a 3-pole, 20 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical power distribution on AC and DC networks. Its thermomagnetic protection unit and C tripping curve deliver a breaking capacity of 10 kA at 380-415 V AC and 20 kA at 220-240 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74320\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003ePoles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current: 20 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eTerminal connection: 1-25 mm² rigid \/ 1-16 mm² flexible, tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles; electrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection with C tripping curve for reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity up to 10 kA at 380-415 V AC for demanding distribution applications\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, supporting a wide range of installations\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator for rapid local fault identification\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with upper or lower busbar comb distributor compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eCircuit protection in electrical panel assemblies and switchboards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eAC and DC power distribution networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74320, Schneider Electric A9F74320, iC60N 3P 20A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516847368,"sku":"SCHA9F74320","price":10.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74320-ic60n-miniature-circuit-breaker-3p-20a-c-curve-399182.jpg?v=1735230417"},{"product_id":"a9f74325-miniature-circuit-breaker-mcb-acti9-ic60n-3p-25a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74325 Acti9 iC60N MCB 3P 25 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74325 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 25 A with a type C tripping curve. It delivers thermomagnetic overcurrent protection for AC and DC distribution networks, with a breaking capacity of 10 kA Icu at 380-415 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74325\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 20 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at up to 180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA (75%) at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection operates on both AC and DC networks for broad application flexibility\u003c\/li\u003e\n  \u003cli\u003eType C tripping curve suits circuits with moderate inrush currents such as transformers and motors\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy to protect downstream components\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator provides immediate local fault signalization\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C supports demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of motor and transformer circuits with moderate inrush loads\u003c\/li\u003e\n  \u003cli\u003eDC distribution panels and mixed AC\/DC switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high breaking capacity and energy limitation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74325, Schneider Electric A9F74325, Acti9 iC60N 3P 25A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065516945672,"sku":"SCHA9F74325","price":13.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74325-miniature-circuit-breaker-mcb-acti9-ic60n-3p-25a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-650751.jpg?v=1735230418"},{"product_id":"a9f74332-ic60n-miniature-circuit-breaker-3p-32a-c-curve","title":"Schneider A9F74332 Acti9 iC60N MCB 3P 32 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74332 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 32 A with a C tripping curve. Designed for electrical power distribution, it provides thermomagnetic overcurrent protection with a breaking capacity of 10 kA at 380-415 V AC, suitable for both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74332\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 32 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC 50\/60 Hz (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC 50\/60 Hz (EN\/IEC 60947-2); 20 kA Icu at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2); 10 kA Icu at 125-180 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve suited for loads with moderate inrush currents such as lighting and distribution circuits\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering installation flexibility\u003c\/li\u003e\n  \u003cli\u003eTrip indicator provides local signalling for quick fault identification\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible (top or bottom), simplifying multi-circuit wiring\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy, protecting downstream equipment\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eElectrical panel protection in light industrial installations\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection for lighting, socket, and general power circuits\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery systems\u003c\/li\u003e\n  \u003cli\u003eSub-distribution boards requiring high breaking capacity at 220-240 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74332, Schneider Electric A9F74332, iC60N 3P 32A MCB, Acti9 32A C curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065517404424,"sku":"SCHA9F74332","price":15.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74332-ic60n-miniature-circuit-breaker-3p-32a-c-curve-839448.jpg?v=1735230418"},{"product_id":"a9f74340-miniature-circuit-breaker-mcb-acti9-ic60n-3p-40a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74340 Acti9 iC60N MCB 3P 40 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74340 is a 3-pole 40 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, with a C tripping curve and thermomagnetic protection unit. Rated for AC and DC networks, it offers a breaking capacity of 10 kA at 380-415 V AC per IEC\/EN 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74340\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB), iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection unit: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-35 mm² rigid \/ 1-25 mm² flexible; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection unit guards against both overload and short-circuit faults on AC and DC networks\u003c\/li\u003e\n  \u003cli\u003eC tripping curve with overcurrent threshold at 8 x In (+\/-20%) for circuits with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises let-through energy during fault events\u003c\/li\u003e\n  \u003cli\u003eTrip indicator and contact position indicator allow fast local fault diagnosis\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible (upper or lower) for straightforward panel assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eThree-phase load protection in low-voltage switchboards and distribution panels\u003c\/li\u003e\n  \u003cli\u003eMotor branch circuit protection in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems requiring certified overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74340, Schneider Electric A9F74340, Acti9 iC60N 3P 40A MCB, Schneider 40A three-pole C-curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065518813448,"sku":"SCHA9F74340","price":18.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74340-miniature-circuit-breaker-mcb-acti9-ic60n-3p-40a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-731478.jpg?v=1735230419"},{"product_id":"a9f74350-miniature-circuit-breaker-mcb-acti9-ic60n-3p-50a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74350 Acti9 iC60N MCB 3P 50 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74350 is a 3-pole 50 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed for electrical power distribution. It features a C tripping curve with a breaking capacity of 10 kA at 380-415 V AC, suitable for both AC and DC network types with thermomagnetic protection technology.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74350\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 50 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 125-180 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA (75%) at 380-415 V AC per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (upper or lower), 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, EN 60947-2, IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve for standard distribution circuits with moderate inrush loads\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC network applications\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for fast fault diagnosis\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eTropicalized (class 2 per IEC 60068-1) for reliable operation in humid environments\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in low-voltage switchboards\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems requiring certified MCB protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and machine electrical panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74350, Schneider Electric A9F74350, iC60N 3P 50A C curve MCB, Acti9 miniature circuit breaker 50A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065518911752,"sku":"SCHA9F74350","price":26.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74350-miniature-circuit-breaker-mcb-acti9-ic60n-3p-50a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-948048.jpg?v=1735230427"},{"product_id":"a9f74363-ic60n-miniature-circuit-breaker-3p-63a-c-curve","title":"Schneider A9F74363 Acti9 iC60N MCB 3P 63 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74363 is a 3-pole 63 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed for overcurrent and short-circuit protection in AC and DC low-voltage distribution networks. It features a C tripping curve with thermomagnetic protection technology and a breaking capacity of 10 kA Icu at 380-415 V AC per EN\/IEC 60947-2, making it suitable for commercial and industrial switchgear applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74363\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current: 63 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC; 20 kA at 220-240 V AC; 10 kA at up to 180 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (fixed)\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-35 mm² rigid \/ 1-25 mm² flexible; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with busbar comb distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator for quick local fault identification\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance 20,000 cycles; electrical endurance 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range from -35 to 70°C for demanding environments\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy during short-circuit events\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in low-voltage switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery systems up to 180 V DC\u003c\/li\u003e\n  \u003cli\u003eFinal distribution boards in residential or light commercial installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring reliable overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74363, Schneider Electric A9F74363, iC60N 3P 63A C-curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065518944520,"sku":"SCHA9F74363","price":30.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74363-ic60n-miniature-circuit-breaker-3p-63a-c-curve-804386.jpg?v=1735230426"},{"product_id":"a9k01306-acti-9-k60n-3p-6a-b-curve-6000-a","title":"Schneider A9K01306 Acti9 K60N MCB 3P 6 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01306 is a 3-pole miniature circuit breaker from the Acti 9 K60N series, rated at 6 A with a B tripping curve. It provides thermomagnetic overcurrent protection for AC distribution circuits, with a breaking capacity of 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01306\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 6 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5-35 mm² rigid \/ 0.5-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical durability: 20,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection technology ensures reliable response to both overload and short-circuit conditions on 3-phase AC circuits\u003c\/li\u003e\n  \u003cli\u003eIcs equals 100% of Icn (6000 A at 400 V AC), eliminating derating when coordinating with upstream devices\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy during fault clearance\u003c\/li\u003e\n  \u003cli\u003eTunnel terminals accept 0.5-35 mm² rigid or 0.5-25 mm² flexible conductors for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003e20,000 mechanical and electrical operating cycles for long service life\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction with a minimum of 56% recycled plastic content\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial building installations\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection in three-phase industrial switchgear panels\u003c\/li\u003e\n  \u003cli\u003eCircuit isolation in electrical distribution systems per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in light industrial and building automation panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, certified by OVE and VDE. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01306, Schneider Electric A9K01306, Acti9 K60N 3P 6A B-curve MCB, Schneider 3-pole miniature circuit breaker 6A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065529135368,"sku":"SCHA9K01306","price":7.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01306-acti-9-k60n-3p-6a-b-curve-6000-a-339168.jpg?v=1735230867"},{"product_id":"a9k01310-acti-9-k60n-3p-10a-b-curve-6000-a","title":"Schneider A9K01310 Acti9 K60N MCB 3P 10 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01310 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, designed for electrical energy distribution in commercial and industrial installations. Rated at 10 A with a B tripping curve and thermomagnetic protection technology, it provides a breaking capacity of 6 kA at 400 V AC in compliance with EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01310\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A (100%)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel terminals, 0.5...35 mm² solid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical endurance: 20,000 cycles each\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eService breaking capacity (Ics) equals rated breaking capacity (Icn) at 6000 A (100%), eliminating the need for derating\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy and protects downstream components during fault conditions\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLower terminals accept comb busbar connections for simplified multi-pole busbar distribution assembly\u003c\/li\u003e\n  \u003cli\u003eWide ambient operating temperature range of -25 to 70°C supports diverse installation environments\u003c\/li\u003e\n  \u003cli\u003eCertified by VDE and OVE for broad European market compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial buildings and offices\u003c\/li\u003e\n  \u003cli\u003eBranch circuit overcurrent protection in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eResidential main and sub-distribution boards\u003c\/li\u003e\n  \u003cli\u003eDIN rail assemblies in metering and distribution enclosures\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and power socket outlet circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, usage category A per IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01310, Schneider Electric A9K01310, Acti9 K60N 3P 10A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065529200904,"sku":"SCHA9K01310","price":8.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01310-acti-9-k60n-3p-10a-b-curve-6000-a-787652.jpg?v=1735230868"},{"product_id":"a9k01316-acti-9-k60n-3p-16a-b-curve-6000-a","title":"Schneider A9K01316 Acti9 K60N MCB 3P 16 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01316 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N series, rated at 16 A with a B tripping curve and a breaking capacity of 6000 A at 400 V AC. It uses thermomagnetic protection technology with an instantaneous trip range of 3 to 5 x In, and is approved for use as an isolating device per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01316\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 16 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5 to 35 mm² rigid \/ 0.5 to 25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFull service breaking capacity (Ics = Icn = 6000 A, 100%) with no derating under service conditions.\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1, reducing the need for a separate disconnector.\u003c\/li\u003e\n  \u003cli\u003eB curve characteristic provides sensitive short-circuit protection for resistive loads and circuits with low inrush current.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 70°C supports reliable performance in demanding installation environments.\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with double connection on the lower comb busbar terminal for flexible panel assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket-outlet circuits with low inrush currents.\u003c\/li\u003e\n  \u003cli\u003eThree-phase distribution panels requiring compact 3-pole overcurrent protection.\u003c\/li\u003e\n  \u003cli\u003eInstallations where the circuit breaker also serves as an isolating switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01316, Schneider Electric A9K01316, Acti9 K60N 3P 16A MCB, K60N B16 3-pole circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065529266440,"sku":"SCHA9K01316","price":6.44,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01316-acti-9-k60n-3p-16a-b-curve-6000-a-767966.jpg?v=1735230871"},{"product_id":"a9k01320-acti-9-k60n-3p-20-a-b-curve-6000-a","title":"Schneider A9K01320 Acti9 K60N MCB 3P 20 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01320 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated at 20 A with a B tripping curve and 6 kA breaking capacity at 400 V AC. Designed for electrical power distribution, it combines thermomagnetic protection technology with compact DIN rail mounting for use in distribution boards and final circuits.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01320\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm (6 x 9 mm modules)\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible (top and bottom)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB curve thermomagnetic protection suitable for resistive and lightly inductive loads with low inrush currents\u003c\/li\u003e\n  \u003cli\u003e6 kA breaking capacity (Icn = Ics at 100%) ensures reliable fault clearance without derating\u003c\/li\u003e\n  \u003cli\u003eCompact 54 mm width (6 modules) optimises space in distribution boards\u003c\/li\u003e\n  \u003cli\u003eWide conductor range (0.5...35 mm² rigid) accommodates diverse wiring requirements\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...70 °C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eHalogen-free product with 56% minimum recycled plastic content supporting sustainability goals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential and commercial electrical distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of resistive loads such as lighting circuits and heating elements\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact 3-pole overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection in DIN rail enclosures\u003c\/li\u003e\n  \u003cli\u003eLow-inrush load protection in building electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, Usage Category A per IEC 60947-2, and certified by OVE and VDE. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01320, Schneider Electric A9K01320, Acti9 K60N 3P 20A B curve MCB, Schneider 3-pole 20A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065529331976,"sku":"SCHA9K01320","price":6.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01320-acti-9-k60n-3p-20-a-b-curve-6000-a-436856.jpg?v=1735230871"},{"product_id":"a9k01325-miniature-circuit-breaker-mcb-acti9-k60n-3p-25a-b-curve-6000a-iec-en-60898-1","title":"Schneider A9K01325 Acti9 K60N MCB 3P 25 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01325 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated at 25 A with a B tripping curve and a breaking capacity of 6000 A at 400 V AC. It provides thermomagnetic overcurrent protection for AC distribution networks and is approved for use as an isolating device per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01325\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB curve trips at 3...5 x In, suited to cable and resistive load protection in final circuits.\u003c\/li\u003e\n  \u003cli\u003eIcs matches Icn at 6000 A - no derating required at rated voltage.\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with double-connection lower busbar comb terminals simplifies panel wiring.\u003c\/li\u003e\n  \u003cli\u003eOperating range -25...70°C with 95% relative humidity tolerance at 55°C.\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction with minimum 56% recycled plastic content supports environmental compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and residential electrical installations.\u003c\/li\u003e\n  \u003cli\u003eProtection of cable circuits and resistive loads in AC power distribution panels.\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and sub-distribution boards requiring DIN rail-mounted MCBs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, usage category A per IEC 60947-2. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01325, Schneider Electric A9K01325, Acti9 K60N 3P 25A MCB, Schneider 25A B curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065530577160,"sku":"SCHA9K01325","price":7.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01325-miniature-circuit-breaker-mcb-acti9-k60n-3p-25a-b-curve-6000a-iecen-60898-1-532606.jpg?v=1735230871"},{"product_id":"a9k01332-acti-9-k60n-3p-32-a-b-curve-6000-a","title":"Schneider A9K01332 Acti9 K60N MCB 3P 32 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01332 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N series, rated at 32 A with a B tripping curve and 6000 A breaking capacity at 400 V AC. It uses thermomagnetic protection technology and DIN rail mounting for electrical energy distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01332\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 32 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B, 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible, torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic B curve protection trips at 3...5 x In for precise overcurrent response\u003c\/li\u003e\n  \u003cli\u003e100% service breaking capacity (Ics = Icn = 6000 A) ensures reliable fault clearing at 400 V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimizes let-through energy under short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eDouble lower connection supports comb busbar distribution blocks for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eApproved for use as an isolation device per EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eElectrical energy distribution boards in commercial and industrial installations\u003c\/li\u003e\n  \u003cli\u003eCircuit protection in low-voltage switchgear panels\u003c\/li\u003e\n  \u003cli\u003eDIN rail assemblies in industrial control and automation enclosures\u003c\/li\u003e\n  \u003cli\u003eThree-phase final distribution circuits requiring compact MCB protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01332, Schneider Electric A9K01332, Acti9 K60N 3P 32A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065530642696,"sku":"SCHA9K01332","price":8.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9k01332-miniature-circuit-breaker-mcb-acti-9-k60n-3p-32-a-b-curve-6000-a-213580.jpg?v=1745439359"},{"product_id":"a9k01340-acti-9-k60n-3p-40-a-b-curve-6000-a","title":"Schneider A9K01340 Acti9 K60N MCB 3P 40 A B Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K01340 is a 3-pole 40 A miniature circuit breaker (MCB) from the Acti 9 K60N series, providing thermomagnetic overcurrent protection in AC distribution systems. Featuring a B-curve tripping characteristic and a 6 kA breaking capacity at 400 V AC, it is suited to circuits with low inrush currents. The device is also approved for use as an isolating device per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K01340\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eOvercurrent trip range: 3...5 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 400 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eB-curve characteristic provides reliable protection for resistive and lightly inductive loads with trip range 3...5 x In\u003c\/li\u003e\n  \u003cli\u003e100% Ics - service breaking capacity equals rated breaking capacity, ensuring full performance throughout the device lifetime\u003c\/li\u003e\n  \u003cli\u003eApproved as an isolating device per EN\/IEC 60898-1, eliminating the need for a separate isolator\u003c\/li\u003e\n  \u003cli\u003eWide conductor acceptance: rigid conductors up to 35 mm² and flexible conductors up to 25 mm²\u003c\/li\u003e\n  \u003cli\u003eHigh mechanical durability of 20,000 operating cycles for long service life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase lighting and resistive load circuits\u003c\/li\u003e\n  \u003cli\u003eLow-voltage industrial distribution panels\u003c\/li\u003e\n  \u003cli\u003eThree-phase AC systems requiring reliable overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K01340, Schneider Electric A9K01340, Acti9 K60N 3-pole 40A B-curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065531396360,"sku":"SCHA9K01340","price":8.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k01340-acti-9-k60n-3p-40-a-b-curve-6000-a-305834.jpg?v=1735230863"},{"product_id":"a9k02306-miniature-circuit-breaker-mcb-acti9-k60n-3p-6a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02306 Acti9 K60N MCB 3P 6 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02306 is a 3-pole, 6 A miniature circuit breaker (MCB) from the Acti 9 K60N series, designed for overcurrent protection in AC low-voltage distribution systems. Rated at 400 V with a C tripping curve and a breaking capacity of 6000 A Icn, it is built for reliable protection in final distribution boards and industrial panels.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02306\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 6 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent trip range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed, 6 x 9 mm modules\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals 0.5...35 mm² rigid \/ 0.5...25 mm² flexible (top and bottom), tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve is suited to lighting and general distribution circuits with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eFull service breaking capacity (Ics = 100% Icn at 400 V AC) - no derating required in service conditions\u003c\/li\u003e\n  \u003cli\u003eApproved for use as an isolating device per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLower terminals support double comb busbar connection, simplifying modular panel wiring\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction with a minimum of 56% recycled plastic content\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and general-purpose AC loads\u003c\/li\u003e\n  \u003cli\u003eLow-voltage distribution systems requiring EN\/IEC 60898-1 compliant overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, certified OVE and VDE. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02306, Schneider Electric A9K02306, Acti9 K60N 3P 6A C-curve MCB, Schneider 3-pole 6A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065532903688,"sku":"SCHA9K02306","price":7.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02306-miniature-circuit-breaker-mcb-acti9-k60n-3p-6a-c-curve-6000a-iecen-60898-1-367905.jpg?v=1735230866"},{"product_id":"a9k02310-miniature-circuit-breaker-mcb-acti9-k60n-3p-10a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02310 Acti9 K60N MCB 3P 10 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02310 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, designed for electrical power distribution. It provides thermomagnetic overcurrent protection with a C tripping curve at a rated current of 10 A and a breaking capacity of 6000 A at 400 V AC.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02310\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: K60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm (6 x 9 mm modules)\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals (upper): 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eConnection terminals (lower): 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve for general-purpose load protection where moderate inrush currents are expected\u003c\/li\u003e\n  \u003cli\u003e100% service breaking capacity (Ics = Icn) at 6000 A ensures full rated performance throughout service life\u003c\/li\u003e\n  \u003cli\u003eWide conductor connection range (0.5...35 mm² rigid) for flexible installation with various cable cross-sections\u003c\/li\u003e\n  \u003cli\u003eCompact 9 mm modular pitch design allows space-efficient layout in distribution boards\u003c\/li\u003e\n  \u003cli\u003eHalogen-free product construction supporting environmentally responsible installation\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1, enabling safe maintenance procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, socket, and general power circuits in electrical panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panel branch circuit protection\u003c\/li\u003e\n  \u003cli\u003eDIN rail assemblies in distribution switchboards requiring 3-pole overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, Use Category A per IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02310, Schneider Electric A9K02310, Acti9 K60N 3P 10A MCB, Schneider 3-pole miniature circuit breaker 10A C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065533657352,"sku":"SCHA9K02310","price":6.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02310-miniature-circuit-breaker-mcb-acti9-k60n-3p-10a-c-curve-6000a-iecen-60898-1-287952.jpg?v=1735230867"},{"product_id":"a9k02316-miniature-circuit-breaker-mcb-acti9-k60n-3p-16a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02316 Acti9 K60N MCB 3P 16 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02316 is a 3-pole Acti 9 K60N miniature circuit breaker (MCB) rated at 16 A with a C tripping curve, designed for overload and short-circuit protection in AC power distribution systems. It provides a breaking capacity of 6000 A Icn at 400 V AC 50\/60 Hz with 100% service breaking capacity (Ics), fully compliant with EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02316\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A (100%) at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible (top and bottom)\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eTropicalization: 2 per IEC 60068-1\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1, enabling safe circuit isolation without an additional isolator\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for fast current limiting, reducing thermal and mechanical stress on downstream components\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (double connection, bottom) for efficient panel wiring\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...70°C for use in demanding environments\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction with a minimum 56% recycled plastic content\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProtection of final circuits in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eIndustrial electrical panels supplying three-phase loads up to 16 A\u003c\/li\u003e\n  \u003cli\u003eSwitchgear assemblies on DIN rail requiring both protection and isolation capability\u003c\/li\u003e\n  \u003cli\u003ePower distribution systems operating on 400 V AC networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1, usage category A per IEC 60947-2, and IEC 60529 (IP20). Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02316, Schneider Electric A9K02316, K60N 3P 16A C curve MCB, Acti 9 miniature circuit breaker 16A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065533722888,"sku":"SCHA9K02316","price":6.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02316-miniature-circuit-breaker-mcb-acti9-k60n-3p-16a-c-curve-6000a-iecen-60898-1-561961.jpg?v=1735230867"},{"product_id":"a9k02320-miniature-circuit-breaker-mcb-acti9-k60n-3p-20a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02320 Acti9 K60N MCB 3P 20 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02320 is a 3-pole Miniature Circuit Breaker (MCB) from the Acti 9 K60N range, rated at 20 A with a C tripping curve and a breaking capacity of 6000 A at 400 V AC. Featuring thermomagnetic protection technology, it is designed for power distribution applications and complies with EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02320\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage [Uimp]: 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eMagnetic trip range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation: Yes per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eBusbar comb connection: Bottom terminals, double connection\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, top and bottom - 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection suits circuits with moderate inrush currents such as resistive and light inductive loads\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics) equals 100% of Icn - no derating in service conditions\u003c\/li\u003e\n  \u003cli\u003eCertified for use as an isolating device per EN\/IEC 60898-1, providing enhanced installation safety\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 ensures fast fault current limiting, reducing thermal and mechanical stress on downstream equipment\u003c\/li\u003e\n  \u003cli\u003eWide conductor compatibility: 0.5...35 mm² rigid and 0.5...25 mm² flexible via tunnel terminals on both top and bottom\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar systems via double connection at bottom terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProtection of outgoing circuits in residential and commercial final distribution boards\u003c\/li\u003e\n  \u003cli\u003eOverload and short-circuit protection for three-phase loads up to 20 A\u003c\/li\u003e\n  \u003cli\u003eIndustrial switchgear panels requiring compact DIN rail-mounted MCBs\u003c\/li\u003e\n  \u003cli\u003eElectrical distribution systems requiring EN\/IEC 60898-1 compliant overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 K60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02320, Schneider Electric A9K02320, Acti9 K60N 3P 20A C curve MCB, 3-pole miniature circuit breaker 6kA.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065533853960,"sku":"SCHA9K02320","price":7.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02320-miniature-circuit-breaker-mcb-acti9-k60n-3p-20a-c-curve-6000a-iecen-60898-1-100319.jpg?v=1735230868"},{"product_id":"a9k02325-miniature-circuit-breaker-mcb-acti9-k60n-3p-25a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02325 Acti9 K60N MCB 3P 25 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02325 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated at 25 A with a C tripping curve and 6 kA breaking capacity at 400 V AC. It uses thermomagnetic protection technology to guard three-phase AC circuits against overload and short-circuit faults, and is approved for use as an isolating device per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02325\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 6000 A (100%) at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated isolation voltage (Ui): 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible (upper and lower)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic trip unit provides both thermal overload and instantaneous magnetic short-circuit protection in a single device\u003c\/li\u003e\n  \u003cli\u003eIcs equals 100% of Icn, delivering full-rated service breaking capacity without derating\u003c\/li\u003e\n  \u003cli\u003eApproved for isolation duty per EN\/IEC 60898-1, removing the need for a separate disconnector\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbars via double-connection lower terminals, simplifying three-phase distribution wiring\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises let-through energy, reducing thermal and mechanical stress on downstream equipment\u003c\/li\u003e\n  \u003cli\u003eWide operating range from -25 to 70°C suits both indoor distribution boards and more demanding industrial enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eThree-phase branch circuit protection in residential and tertiary electrical installations\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and machine switchboards requiring thermomagnetic MCB protection\u003c\/li\u003e\n  \u003cli\u003eSub-distribution switchboards where isolation capability is required at the breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02325, Schneider Electric A9K02325, Acti 9 K60N 3P 25A C curve MCB, Schneider 3-pole miniature circuit breaker 25A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065533919496,"sku":"SCHA9K02325","price":7.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02325-miniature-circuit-breaker-mcb-acti9-k60n-3p-25a-c-curve-6000a-iecen-60898-1-449814.jpg?v=1735230868"},{"product_id":"a9k02332-miniature-circuit-breaker-mcb-acti9-k60n-3p-32a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02332 Acti9 K60N MCB 3P 32 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02332 is a 3-pole, 32 A miniature circuit breaker (MCB) from the Acti 9 K60N series, featuring a C tripping curve and a breaking capacity of 6,000 A at 400 V AC. Designed for electrical power distribution, it uses thermomagnetic protection technology and mounts on standard DIN rail for straightforward panel installation.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02332\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P, 3 protected poles\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 32 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6,000 A at 400 V AC (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eService breaking capacity [Ics] equals 100% of Icn - no derating at 400 V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 per EN\/IEC 60898-1 minimizes let-through energy to downstream equipment\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks via double lower connection\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction for reduced environmental impact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase circuits in industrial distribution panels\u003c\/li\u003e\n  \u003cli\u003eMotor branch circuit protection requiring C curve characteristics\u003c\/li\u003e\n  \u003cli\u003eSub-distribution panels in light commercial and industrial installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and usage category A per IEC 60947-2. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02332, Schneider Electric A9K02332, Acti9 K60N 3P 32A MCB, K60N C32 3-pole circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065534017800,"sku":"SCHA9K02332","price":7.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02332-miniature-circuit-breaker-mcb-acti9-k60n-3p-32a-c-curve-6000a-iecen-60898-1-415952.jpg?v=1735230863"},{"product_id":"a9k02340-miniature-circuit-breaker-mcb-acti9-k60n-3p-40a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02340 Acti9 K60N MCB 3P 40 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02340 is a 3-pole, 40 A miniature circuit breaker (MCB) from the Acti 9 K60N series, designed for AC electrical power distribution. With a C tripping curve, thermomagnetic protection technology, and a 6 kA breaking capacity at 400 V AC, it delivers reliable overcurrent and short-circuit protection for 3-phase branch circuits.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02340\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 (K60N)\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn] \/ service breaking capacity [Ics]: 6 kA at 400 V AC, 100% Ics (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 81 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 0.5...35 mm² rigid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70°C\u003c\/li\u003e\n  \u003cli\u003eMechanical \/ electrical durability: 20,000 \/ 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, OVE\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection suited to general-purpose power distribution loads\u003c\/li\u003e\n  \u003cli\u003eFull 6 kA service breaking capacity (100% Ics) at 400 V AC for consistent fault performance\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for effective energy limitation during short-circuit events\u003c\/li\u003e\n  \u003cli\u003eBottom terminals support comb busbar with double connection for flexible panel layouts\u003c\/li\u003e\n  \u003cli\u003eWide conductor range accepts 0.5...35 mm² rigid or 0.5...25 mm² flexible cable\u003c\/li\u003e\n  \u003cli\u003eOperating temperature range of -25...70°C for use in demanding installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection in industrial control panels and distribution enclosures\u003c\/li\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in 3-phase AC distribution networks\u003c\/li\u003e\n  \u003cli\u003eElectrical power distribution systems requiring DIN rail-mounted protection devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02340, Schneider Electric A9K02340, Acti9 K60N 3P 40A MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065534148872,"sku":"SCHA9K02340","price":8.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02340-miniature-circuit-breaker-mcb-acti9-k60n-3p-40a-c-curve-6000a-iecen-60898-1-747478.jpg?v=1735230868"},{"product_id":"a9k02350-miniature-circuit-breaker-mcb-acti9-k60n-3p-50a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02350 Acti9 K60N MCB 3P 50 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02350 is a 3P miniature circuit breaker from the Acti9 K60N range, rated 50 A with C tripping curve. It provides overload and short-circuit protection for final circuits in domestic and commercial distribution boards, rated 6000A under IEC\/EN 60898-1. Mounts on 35mm DIN rail in standard 18mm module widths per pole.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePart number: A9K02350\u003c\/li\u003e\n\u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eSeries: Acti9 K60N\u003c\/li\u003e\n\u003cli\u003ePoles: 3P\u003c\/li\u003e\n\u003cli\u003eRated current: 50 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000A (IEC\/EN 60898-1)\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400V AC 3-phase\u003c\/li\u003e\n\u003cli\u003eMounting: 35mm DIN rail, 18mm\/pole\u003c\/li\u003e\n\u003cli\u003eStandards: IEC\/EN 60898-1, CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eC curve - suited to general domestic and commercial wiring with mixed or moderate inrush loads\u003c\/li\u003e\n\u003cli\u003eActi9 18mm module system - fits standard domestic and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eCompatible with Acti9 Vigi RCD blocks and comb busbars\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection in domestic and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eConsumer units and MCB boards using 18mm DIN rail Acti9 modules\u003c\/li\u003e\n\u003cli\u003eSub-circuit protection for lighting, socket, and appliance circuits\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Schneider A9K02350, Acti9 K60N 3P 50 A C curve MCB, A9K02350 Acti9 domestic circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065534247176,"sku":"SCHA9K02350","price":11.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02350-miniature-circuit-breaker-mcb-acti9-k60n-3p-50a-c-curve-6000a-iecen-60898-1-261124.jpg?v=1735230871"},{"product_id":"18638-miniature-circuit-breaker-mcb-acti9-ng125n-3p-50a-c-curve-25ka-iec-en-60947-2","title":"Schneider 18638 Acti9 NG125N Miniature circuit breaker 3P C50A 25kA","description":"\u003cp\u003eThe Schneider Electric 18638 (NG125N) is a 3-pole miniature circuit breaker from the Acti 9 range, rated at 50A with a C tripping characteristic. Designed for electrical energy distribution, it offers a breaking capacity of 25kA at 380-415V AC and supports both AC and DC network types with thermomagnetic protection technology.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18638\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 NG125\u003c\/li\u003e\n  \u003cli\u003eDevice short name: NG125N\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 50A at 40°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240V AC 50\/60Hz \/ 380-415V AC 50\/60Hz \/ 440V AC 50\/60Hz \/ 500V AC 50\/60Hz \/ up to 375V DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50kA at 220-240V AC; 25kA at 380-415V AC; 20kA at 440V AC; 10kA at 500V AC; 20kA at up to 375V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 37.5kA at 220-240V AC; 18.75kA at 380-415V AC; 15kA at 440V AC; 7.5kA at 500V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690V AC 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: 35mm symmetrical DIN rail, clip-on\u003c\/li\u003e\n  \u003cli\u003eHandle position: Vertical\u003c\/li\u003e\n  \u003cli\u003eWidth: 81mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 103mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 81mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.72kg\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel terminals 1.5-50mm² rigid \/ 1-35mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 20mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eIK rating: IK05 (EN\/IEC 62262)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per IEC 60947-2, enabling safe maintenance and lockout procedures\u003c\/li\u003e\n  \u003cli\u003eIntegrated lockout preparation with built-in locking capability for enhanced safety compliance\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for clear local ON\/OFF and fault status reading\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks, supporting 9mm pitch rows for efficient panel wiring\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-30 to 70°C) for reliable performance in demanding environments\u003c\/li\u003e\n  \u003cli\u003eTropicalisation rating 2 (IEC 60068-1) and high humidity tolerance for use in harsh conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal and sub-distribution boards in commercial and industrial electrical installations\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in AC distribution panels at 380-415V and 220-240V\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery-backed power distribution systems (up to 375V DC)\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high breaking capacity up to 50kA\u003c\/li\u003e\n  \u003cli\u003eApplications requiring lockable circuit protection for safety and maintenance isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18638, Schneider Electric 18638, NG125N 3P 50A MCB, Acti9 NG125N C50 3-pole circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065989656840,"sku":"SCH18638","price":98.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18638-miniature-circuit-breaker-mcb-acti9-ng125n-3p-50a-c-curve-25ka-iecen-60947-2-582196.jpg?v=1735224428"},{"product_id":"18639-miniature-circuit-breaker-mcb-acti9-ng125n-3p-63a-c-curve-25ka-iec-en-60947-2","title":"Schneider 18639 Acti9 NG125N Miniature circuit breaker 3P C63A 25kA","description":"\u003cp\u003eThe Schneider Electric 18639 is a 3-pole miniature circuit breaker from the Acti 9 NG125N series, designed for electrical energy distribution. It delivers a rated current of 63 A at 40°C with a C tripping characteristic and a breaking capacity of 25 kA at 380-415 V AC, conforming to IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18639\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 NG125\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: NG125N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 63 A at 40°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50 kA at 220-240 V AC 50\/60 Hz; 25 kA at 380-415 V AC 50\/60 Hz; 20 kA at 440 V AC 50\/60 Hz; 10 kA at 500 V AC 50\/60 Hz; 20 kA at \u0026lt;=375 V DC\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 37.5 kA (220-240 V AC); 18.75 kA (380-415 V AC); 15 kA (440 V AC); 7.5 kA (500 V AC); 20 kA (\u0026lt;=375 V DC)\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 V \/ 380-415 V \/ 440 V \/ 500 V AC 50\/60 Hz; \u0026lt;=375 V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In\u003c\/li\u003e\n  \u003cli\u003eUtilisation category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 103 x 81 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.72 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eIK protection rating: IK05 per EN\/IEC 62262\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, clip-on\u003c\/li\u003e\n  \u003cli\u003eHandle position: Vertical\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel terminals 1.5-50 mm² rigid; 1-35 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eWire strip length: 20 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eBusbar comb compatible: Yes (9 mm pitch, 9 rows)\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 25 kA at 380-415 V AC, suitable for demanding industrial distribution applications\u003c\/li\u003e\n  \u003cli\u003eThermomagnetic protection unit provides reliable overcurrent and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, offering installation flexibility\u003c\/li\u003e\n  \u003cli\u003eLockable handle with integrated locking preparation for controlled access and safety\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for quick local status reading\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting with busbar comb compatibility for fast, organized panel assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in electrical distribution panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high breaking capacity protection\u003c\/li\u003e\n  \u003cli\u003eApplications combining AC and DC network protection requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18639, Schneider Electric 18639, NG125N 3P 63A MCB, Acti9 63A circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065991688456,"sku":"SCH18639","price":103.17,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18639-miniature-circuit-breaker-mcb-acti9-ng125n-3p-63a-c-curve-25ka-iecen-60947-2-456134.jpg?v=1735224427"},{"product_id":"18640-miniature-circuit-breaker-mcb-acti9-ng125n-3p-80a-c-curve-25ka-iec-en-60947-2","title":"Schneider 18640 Acti9 NG125N Miniature circuit breaker 3P C80A 25kA","description":"\u003cp\u003eThe Schneider Electric 18640 (Acti9 NG125N) is a 3-pole miniature circuit breaker rated at 80 A with a C tripping characteristic, designed for electrical power distribution. It delivers a breaking capacity of 25 kA at 380-415 V AC and is compliant with EN\/IEC 60947-2, making it suitable for both AC and DC network applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18640\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 NG125\u003c\/li\u003e\n  \u003cli\u003eDevice short name: NG125N\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 80 A at 40 °C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50 kA at 220-240 V AC \/ 25 kA at 380-415 V AC \/ 20 kA at 440 V AC \/ 10 kA at 500 V AC \/ 20 kA at 375 V DC (per EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 37.5 kA at 220-240 V AC \/ 18.75 kA at 380-415 V AC \/ 15 kA at 440 V AC \/ 7.5 kA at 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 81 x 103 x 81 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.72 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eIK protection rating: IK05 per EN\/IEC 62262\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, clip-on system\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 16-70 mm² rigid \/ 10-50 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 6 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 20 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 5,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 25 kA at 380-415 V AC for robust short-circuit protection in demanding installations\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC network types, providing versatile deployment options\u003c\/li\u003e\n  \u003cli\u003eLockable handle with integrated locking mechanism for controlled access and safety\u003c\/li\u003e\n  \u003cli\u003eTrip indicator and ON\/OFF position indicator for clear local status readout\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -30 to 70 °C for use in harsh environments\u003c\/li\u003e\n  \u003cli\u003eContact position indicator included for visual confirmation of switching state\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain or sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in low-voltage switchgear and controlgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDC applications including photovoltaic and battery-backed power distribution systems\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high breaking capacity protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18640, Schneider Electric 18640, Acti9 NG125N 80A 3P, MCB 80A C-curve 25kA.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065992212744,"sku":"SCH18640","price":118.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18640-miniature-circuit-breaker-mcb-acti9-ng125n-3p-80a-c-curve-25ka-iecen-60947-2-908236.jpg?v=1735224427"},{"product_id":"18642-miniature-circuit-breaker-mcb-acti9-ng125n-3p-100a-c-curve-25ka-iec-en-60947-2","title":"Schneider 18642 Acti9 NG125N Miniature circuit breaker 3P C100A 25kA","description":"\u003cp\u003eSchneider Electric 18642 is a 3-pole, 100 A miniature circuit breaker (MCB) from the Acti 9 NG125N series, designed for AC and DC electrical distribution. It uses thermomagnetic protection with a C tripping curve, delivering up to 25 kA breaking capacity at 380-415 V AC and 50 kA at 220-240 V AC.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: 18642\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries: Acti 9 NG125\u003c\/li\u003e\n  \u003cli\u003eDevice code: NG125N\u003c\/li\u003e\n  \u003cli\u003ePoles: 3P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 100 A at 40°C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 \/ 380-415 \/ 440 \/ 500 V AC; up to 375 V DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 50 kA at 220-240 V AC; 25 kA at 380-415 V AC; 20 kA at 440 V AC \/ up to 375 V DC; 10 kA at 500 V AC\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 690 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 8 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, click-on system\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 81 x 103 x 81 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.72 kg\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type, 16-70 mm² rigid \/ 10-50 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 6 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -30 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolating device per IEC 60947-2, enabling safe maintenance isolation\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for installation flexibility\u003c\/li\u003e\n  \u003cli\u003eIntegrated locking provision for lockout safety procedures\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for clear local signalization\u003c\/li\u003e\n  \u003cli\u003eAccepts rigid 16-70 mm² and flexible 10-50 mm² cables via tunnel terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain and sub-distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in AC and DC power distribution panels\u003c\/li\u003e\n  \u003cli\u003eOutgoing circuit protection where high breaking capacity is required\u003c\/li\u003e\n  \u003cli\u003eIndustrial switchgear requiring safe isolation capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider 18642, Schneider Electric 18642, NG125N 3P 100A MCB, Schneider NG125N circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065996538120,"sku":"SCH18642","price":122.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/18642-miniature-circuit-breaker-mcb-acti9-ng125n-3p-100a-c-curve-25ka-iecen-60947-2-564878.jpg?v=1735224427"},{"product_id":"a9f84332-ic60h-miniature-circuit-breaker-3p-32a-c-curve","title":"Schneider A9F84332 Acti9 iC60H MCB 3P 32 A C Curve 15kA","description":"\u003cp\u003eThe Schneider Electric A9F84332 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 32 A with a C tripping curve. It delivers thermomagnetic overcurrent and short-circuit protection with a breaking capacity of 15 kA at 380-415 V AC, suitable for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84332\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P (3 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 32 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10,000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 15 kA at 380-415 V AC \/ 30 kA at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA at 380-415 V AC \/ 15 kA at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUtilization category: A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible conductors, tightening torque 3.5 N.m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator for fast, visible fault identification\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides clear on\/off status at a glance\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower connection\u003c\/li\u003e\n  \u003cli\u003eHigh mechanical endurance of 20,000 cycles and electrical endurance of 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV, rated for installation at the origin of a supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring three-phase AC or DC circuit protection\u003c\/li\u003e\n  \u003cli\u003ePower distribution systems using busbar-fed modular MCB arrangements\u003c\/li\u003e\n  \u003cli\u003eProtection of three-phase loads where high breaking capacity is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F84332, Schneider Electric A9F84332, iC60H 3P 32A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075374575880,"sku":"SCHA9F84332","price":18.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9f84332-schneider-electric-miniature-circuit-breaker-mcb-ic60h-3p-32a-c-curve-4655510.jpg?v=1757426449"},{"product_id":"a9f94310-ic60l-miniature-circuit-breaker-3p-10a-c-curve","title":"Schneider A9F94310 Acti9 iC60L MCB 3P 10 A C Curve 25kA","description":"\u003cp\u003eThe Schneider Electric A9F94310 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60L range, rated at 10 A with a C tripping curve. Compatible with both AC and DC networks, it delivers a breaking capacity of 25 kA at 380-415 V AC per IEC 60947-2, making it a high-performance solution for electrical distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F94310\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtective unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 15 kA at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 25 kA at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 440 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 25 kA at 102-144 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUtilization category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 54 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.375 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible, tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 25 kA at 380-415 V AC (IEC 60947-2) for demanding distribution environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with AC and DC networks, offering broad application flexibility\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for effective current limiting per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eTrip indicator provides local signaling for quick fault identification\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with upper or lower comb busbar distribution blocks for flexible panel wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in industrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eAC and DC electrical distribution systems requiring high breaking capacity\u003c\/li\u003e\n  \u003cli\u003eSwitchboard assemblies where DIN rail mounting and busbar compatibility are required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F94310, Schneider Electric A9F94310, iC60L 3P 10A C curve MCB, Acti9 miniature circuit breaker 10A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075482808584,"sku":"SCHA9F94310","price":34.98,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f94310-ic60l-miniature-circuit-breaker-3p-10a-c-curve-149769.jpg?v=1735230787"},{"product_id":"a9k02313-miniature-circuit-breaker-mcb-acti9-k60n-3p-13a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K02313 Acti9 K60N MCB 3P 13 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K02313 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 K60N range, rated at 13 A with a C tripping curve. It provides thermomagnetic overcurrent protection for AC distribution circuits, with a breaking capacity of 6000 A at 400 V AC 50\/60 Hz in accordance with EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K02313\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 K60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: K60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 3P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 3\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 13 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 6000 A (100%) at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection range: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm (6 x 9 mm modules)\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.36 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...70 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel terminals (top and bottom), 0.5...35 mm² solid \/ 0.5...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection suits resistive and slightly inductive loads with moderate inrush currents.\u003c\/li\u003e\n  \u003cli\u003eFull 100% service breaking capacity (Ics = Icn = 6000 A) ensures reliable performance throughout the product's service life.\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with 9 mm module pitch allows compact integration in standard distribution boards.\u003c\/li\u003e\n  \u003cli\u003eWide connection range (0.5...35 mm² solid) accommodates diverse cable cross-sections without additional adapters.\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1, enabling safe maintenance switching.\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for simplified multi-circuit wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, heating, and general power circuits in low-voltage panels.\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact 3-pole overcurrent protection.\u003c\/li\u003e\n  \u003cli\u003eDistribution of electrical energy in AC installations up to 400 V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K02313, Schneider Electric A9K02313, Acti9 K60N 3P 13A C curve MCB, Schneider 3-pole miniature circuit breaker 13A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075504271624,"sku":"SCHA9K02313","price":7.63,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k02313-miniature-circuit-breaker-mcb-acti9-k60n-3p-13a-c-curve-6000a-iecen-60898-1-552191.jpg?v=1735230871"},{"product_id":"248039-plht-c80-3-miniature-circuit-breaker-3p-c80a-25ka","title":"Eaton 248039 PLHT-C80\/3 MCB 3P 80 A C Curve 20kA DIN Rail","description":"\u003cp\u003eThe Eaton PLHT-C80\/3 (article 248039) is a 3-pole 80 A industrial miniature circuit breaker from the PLHT High-Tripping series, designed to provide overload and short-circuit protection on DIN-rail final circuits in industrial installations. Rated and tested to IEC\/EN 60947-2, it meets the more demanding requirements of industrial switchgear and controlgear rather than the household appliance standard, making it the correct choice for factory distribution boards, machine control panels, and commercial HVAC switchgear. Tripping characteristic C gives reliable protection against moderate inrush currents typical of resistive and lightly inductive industrial loads.\u003c\/p\u003e\n\n\u003cp\u003eSpecifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog number: 248039\u003c\/li\u003e\n\u003cli\u003eManufacturer part number (MPN): PLHT-C80\/3\u003c\/li\u003e\n\u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n\u003cli\u003eEAN: 4015082480394\u003c\/li\u003e\n\u003cli\u003eSeries: PLHT (High-Tripping MCB)\u003c\/li\u003e\n\u003cli\u003eType: Miniature circuit breaker (MCB), industrial-grade\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 3\u003c\/li\u003e\n\u003cli\u003eRated current (In): 80 A\u003c\/li\u003e\n\u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n\u003cli\u003eRated operational voltage (Ue): 400 V AC\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity (Icu): 20 kA at 400 V AC per IEC\/EN 60947-2\u003c\/li\u003e\n\u003cli\u003eStandard: IEC\/EN 60947-2 (industrial switchgear and controlgear)\u003c\/li\u003e\n\u003cli\u003eIP rating: IP40\u003c\/li\u003e\n\u003cli\u003eMounting: 35 mm DIN rail\u003c\/li\u003e\n\u003cli\u003eConductor cross-section: 2.5 ... 50 mm²\u003c\/li\u003e\n\u003cli\u003eMechanical durability: 20,000 operating cycles\u003c\/li\u003e\n\u003cli\u003eGross weight: 692.3 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertified to IEC\/EN 60947-2, satisfying industrial switchgear requirements for rated performance, endurance, and dielectric withstand\u003c\/li\u003e\n\u003cli\u003eShort-circuit breaking capacity of 20 kA at 400 V AC (Icu) provides robust protection in installations with high available fault currents\u003c\/li\u003e\n\u003cli\u003eWide conductor connection range of 2.5 ... 50 mm² accommodates diverse cable sizes without requiring additional terminal adapters\u003c\/li\u003e\n\u003cli\u003eStandard 35 mm DIN rail mounting ensures straightforward integration into existing industrial enclosures and distribution panels\u003c\/li\u003e\n\u003cli\u003eMechanical durability rated at 20,000 cycles supports long service life in applications with frequent switching operations\u003c\/li\u003e\n\u003cli\u003eIP40 degree of protection guards internal components against ingress of solid particles in typical indoor switchgear environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial power distribution boards requiring IEC\/EN 60947-2 compliant final circuit protection\u003c\/li\u003e\n\u003cli\u003eMotor circuit final protection where characteristic C accommodates moderate motor starting inrush currents\u003c\/li\u003e\n\u003cli\u003eFactory automation and machine tool wiring panels with high available short-circuit currents\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial HVAC switchgear protecting compressor and fan motor circuits\u003c\/li\u003e\n\u003cli\u003eBuilding services distribution in commercial premises where industrial-grade certification is specified\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAlso known as: Eaton PLHT-C80\/3, Eaton 248039, Eaton PLHT C80 3-pole, Eaton industrial MCB 80A.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251471184136,"sku":"ETN248039","price":83.72,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/248039-plht-c803-miniature-circuit-breaker-3p-c80a-25ka-486744.jpg?v=1735225322"}],"url":"https:\/\/gabbyelectric.com\/en-us\/collections\/3-pole-mcb.oembed?page=10","provider":"Gabby Electric","version":"1.0","type":"link"}