{"title":"2 Pole MCB","description":"\u003cp\u003eDiscover reliable protection with our \u003cstrong data-start=\"305\" data-end=\"319\"\u003e2 pole MCB\u003c\/strong\u003e range, designed for safe and efficient power distribution. These compact circuit breakers protect against overloads and short circuits, making them ideal for both residential and commercial applications. Engineered by trusted global brands, each 2 pole breaker ensures stable performance, easy installation, and full compliance with international safety standards. Perfect for single-phase or split-phase systems that demand dependable circuit protection.\u003c\/p\u003e","products":[{"product_id":"a9f74202-miniature-circuit-breaker-mcb-acti9-ic60n-2p-2a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74202 Acti9 iC60N MCB 2P 2 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74202 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 2 A with a C tripping curve. Designed for electrical power distribution, it provides thermomagnetic overcurrent protection on both AC and DC networks with a breaking capacity up to 50 kA at 380-415 V AC per IEC\/EN 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74202\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 2 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (EN\/IEC 60898-1); 50 kA Icu at 220-415 V AC (EN\/IEC 60947-2); 10 kA Icu at 72-125 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 50 kA 100% at 380-415 V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eQuality marks: NF\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic trip unit provides reliable overload and short-circuit protection on AC and DC networks\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity of 50 kA Icu (IEC\/EN 60947-2) ensures suitability for demanding industrial installations\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises let-through energy, reducing stress on downstream equipment\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible (upper or lower) for simplified distribution board wiring\u003c\/li\u003e\n  \u003cli\u003eTrip position indicator and handle-operated local signalling for quick fault identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring IEC 60947-2 rated devices\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic or battery backup systems (up to 125 V DC)\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection for sensitive loads requiring low let-through energy (class 3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74202, Schneider Electric A9F74202, Acti9 iC60N 2A 2P C curve MCB, Schneider 2A C curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515340040,"sku":"SCHA9F74202","price":14.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74202-miniature-circuit-breaker-mcb-acti9-ic60n-2p-2a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-138301.jpg?v=1735230419"},{"product_id":"a9f74204-miniature-circuit-breaker-mcb-acti9-ic60n-2p-4a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74204 Acti9 iC60N MCB 2P 4 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74204 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 4 A with a C tripping curve. It delivers thermomagnetic overcurrent protection for AC and DC networks, offering up to 50 kA breaking capacity at 380-415 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74204\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P (2 protected)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 4 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC and DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 380-415 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible (upper or lower)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eQuality marks: NF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve suited to general distribution circuits with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eApproved for use as an isolation device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for high energy-limiting performance\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator for quick local fault identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring compact MCB overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage AC and DC distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74204, Schneider Electric A9F74204, iC60N 2P 4A C curve MCB, Acti 9 iC60N C4.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515471112,"sku":"SCHA9F74204","price":14.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9f74204-miniature-circuit-breaker-mcb-acti9-ic60n-2p-4a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-2692843.jpg?v=1757426565"},{"product_id":"a9f74206-ic60n-miniature-circuit-breaker-2p-6a-c-curve","title":"Schneider A9F74206 Acti9 iC60N MCB 2P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74206 is a 2-pole, 6 A thermomagnetic miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for overcurrent protection in AC and DC electrical distribution networks. Its C tripping curve delivers a breaking capacity of 10 kA Icu at 380-415 V AC per IEC 60947-2 and 6,000 A Icn at 400 V AC per IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74206\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6,000 A Icn at 400 V AC (IEC\/EN 60898-1); 10 kA Icu at 380-415 V AC; 20 kA Icu at 220-240 V AC (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (IEC\/EN 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolator per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for local signaling of fault conditions\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks on upper or lower terminals\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 provides energy-limiting performance to reduce downstream damage\u003c\/li\u003e\n  \u003cli\u003eTropicalization class 2 and 95% relative humidity rating support use in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and power distribution switchboards\u003c\/li\u003e\n  \u003cli\u003eDIN rail-mounted circuit protection in automation enclosures\u003c\/li\u003e\n  \u003cli\u003eAC and DC system overcurrent protection up to 415 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74206, Schneider Electric A9F74206, iC60N 2P 6A C curve MCB, Acti9 miniature circuit breaker 6A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515569416,"sku":"SCHA9F74206","price":8.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74206-ic60n-miniature-circuit-breaker-2p-6a-c-curve-345059.jpg?v=1735230418"},{"product_id":"a9f74210-ic60n-miniature-circuit-breaker-2p-10a-c-curve","title":"Schneider A9F74210 Acti9 iC60N MCB 2P 10 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74210 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 10 A with a C tripping curve. Designed for electrical power distribution, it delivers a breaking capacity of 10 kA at 380-415 V AC and supports both AC and DC network types with thermomagnetic protection technology.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74210\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 125 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² solid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, EN 60947-2, IEC 60898-1, EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermomagnetic protection for reliable overload and short-circuit response in standard distribution applications\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible (top or bottom), simplifying multi-device panel wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for quick status identification\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-35 to 70 °C) suitable for demanding environments\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for reduced let-through energy during fault events\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring reliable overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in electrical power distribution systems\u003c\/li\u003e\n  \u003cli\u003eDC network applications such as photovoltaic or battery-backed systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74210, Schneider Electric A9F74210, iC60N 2P 10A MCB, Acti9 miniature circuit breaker 10A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065515602184,"sku":"SCHA9F74210","price":7.97,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/schneider-electric-a9f74210-10a-2-pole-miniature-circuit-breaker-mcb-400v-type-c-curve-6848754.jpg?v=1757426566"},{"product_id":"a9f79206-miniature-circuit-breaker-mcb-acti9-ic60n-2p-6a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F79206 Acti9 iC60N MCB 2P 6 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F79206 is a 2-pole miniature circuit breaker (MCB) from the Acti9 iC60N range, rated at 6 A with a C tripping curve. Designed for distribution applications, it delivers a breaking capacity of 10 kA at 380-415 V AC per IEC\/EN 60947-2 and 6000 A at 400 V AC per IEC\/EN 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F79206\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage: 220-240 V AC, 380-415 V AC, 440 V AC, up to 125 V DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 10 kA Icu at 380-415 V AC (IEC\/EN 60947-2); 6000 A Icn at 400 V AC (IEC\/EN 60898-1)\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eUtilisation category: Category A (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm DIN rail, clip-on\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal top or bottom, 1-25 mm² rigid or 1-16 mm² flexible copper\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm | Height: 85 mm | Depth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529); IP40 in modular enclosure\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: 0-2000 m\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC\/EN 60947-2, IEC\/EN 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per both IEC\/EN 60898-1 and IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for enhanced energy limitation and downstream equipment protection\u003c\/li\u003e\n  \u003cli\u003eCompatible with top or bottom comb busbar connections at 18 mm phase pitch\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for fast visual fault detection without additional tools\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-35 to 70 °C) suitable for demanding environments\u003c\/li\u003e\n  \u003cli\u003ePVC-free construction with recyclability potential of 54%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and machinery protection circuits\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems up to 125 V\u003c\/li\u003e\n  \u003cli\u003eSub-distribution boards requiring high breaking capacity at low current ratings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 60947-2 and IEC\/EN 60898-1. Part of the Schneider Electric Acti9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F79206, Schneider Electric A9F79206, iC60N 2P 6A C curve MCB, Acti9 miniature circuit breaker 6A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065522417928,"sku":"SCHA9F79206","price":13.43,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f79206-miniature-circuit-breaker-mcb-acti9-ic60n-2p-6a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-899803.jpg?v=1735230476"},{"product_id":"a9f73201-miniature-circuit-breaker-mcb-acti9-ic60n-2p-1a-b-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F73201 Acti9 iC60N MCB 2P 1 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73201 is a 2-pole, 1 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed to protect electrical distribution circuits against overload and short-circuit faults. It features a B tripping curve, a rated breaking capacity of 6,000 A at 400 V AC per IEC 60898-1, and supports both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73201\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P (2 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 1 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 220-415 V AC \/ 25 kA at 440 V AC \/ 10 kA at up to 125 V DC per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible, tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles \/ Electrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for use as an isolating device per IEC\/EN 60898-1 and IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for immediate local fault indication\u003c\/li\u003e\n  \u003cli\u003eCompatible with 9 mm pitch busbar comb systems, upper or lower connection, 4 rows\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C for demanding environments\u003c\/li\u003e\n  \u003cli\u003eDifferential protection module can be added as a separate accessory block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of sensitive loads with low inrush current requiring a B tripping curve\u003c\/li\u003e\n  \u003cli\u003eIndustrial electrical panel protection in mixed AC and DC installations\u003c\/li\u003e\n  \u003cli\u003eElectrical energy distribution systems requiring high breaking capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, IEC 60947-2, EN 60898-1, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73201, Schneider Electric A9F73201, iC60N 2P 1A B curve MCB, Acti 9 miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075299307784,"sku":"SCHA9F73201","price":11.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9f73201-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60n-2p-1a-b-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-6703961.jpg?v=1757426448"},{"product_id":"a9f73202-miniature-circuit-breaker-mcb-acti9-ic60n-2p-2a-b-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F73202 Acti9 iC60N MCB 2P 2 A B Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F73202 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60N series, rated at 2 A with a B tripping curve. It provides thermomagnetic overcurrent protection for both AC and DC networks, with a breaking capacity of 6000 A Icn at 400 V AC per EN\/IEC 60898-1 and up to 50 kA Icu at 220-415 V AC per EN\/IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73202\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 2 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC 50\/60 Hz (EN\/IEC 60898-1); 50 kA Icu at 220-415 V AC 50\/60 Hz (EN\/IEC 60947-2); 10 kA Icu at up to 125 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² solid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for both AC and DC networks, offering broad application flexibility\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity up to 50 kA Icu makes it suitable for demanding industrial installations\u003c\/li\u003e\n  \u003cli\u003eB curve for sensitive loads requiring tripping at lower overcurrent levels\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local signaling\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for efficient panel wiring\u003c\/li\u003e\n  \u003cli\u003eCompact 2-module DIN rail design with 9 mm pitch rows\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of sensitive loads such as measuring instruments and electronic equipment\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and automation systems operating on AC or DC networks\u003c\/li\u003e\n  \u003cli\u003eLow-voltage switchgear assemblies requiring high breaking capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73202, Schneider Electric A9F73202, Acti9 iC60N 2A B curve MCB, Schneider 2-pole miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075299569928,"sku":"SCHA9F73202","price":15.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73202-miniature-circuit-breaker-mcb-acti9-ic60n-2p-2a-b-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-954466.jpg?v=1735230354"},{"product_id":"a9f73210-miniature-circuit-breaker-mcb-acti9-ic60n-2p-10a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F73210 Acti9 iC60N MCB 2P 10 A B Curve 10kA","description":"\u003cp\u003eSchneider Electric A9F73210 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 10 A with a B tripping curve for electrical power distribution. Built with thermomagnetic protection technology, it delivers a breaking capacity of 10 kA Icu at 380-415 V AC per IEC 60947-2, suitable for both AC and DC network types.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F73210\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P - protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: B\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC \/ 20 kA at 220-240 V AC \/ 10 kA at 72-125 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 4 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible, tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles - electrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection on both poles for reliable overload and short-circuit response\u003c\/li\u003e\n  \u003cli\u003eB tripping curve for circuits with low inrush currents\u003c\/li\u003e\n  \u003cli\u003eCompatible with top or bottom comb busbar distribution blocks\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for fast local fault identification\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eSuitable for both AC and DC networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and general power circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F73210, Schneider Electric A9F73210, iC60N 2P 10A B curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075300880648,"sku":"SCHA9F73210","price":8.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f73210-miniature-circuit-breaker-mcb-acti9-ic60n-2p-10a-b-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-903421.jpg?v=1735230349"},{"product_id":"a9f74201-miniature-circuit-breaker-mcb-acti9-ic60n-2p-1a-c-curve-6000a-iec-en-60898-1-50ka-iec-en-60947-2","title":"Schneider A9F74201 Acti9 iC60N MCB 2P 1 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74201 is an Acti 9 iC60N 2-pole Miniature Circuit Breaker rated at 1 A with a C tripping curve, designed for electrical power distribution. It provides thermomagnetic protection with a breaking capacity of 6,000 A Icn at 400 V AC per EN\/IEC 60898-1 and up to 50 kA Icu at 220-415 V AC per EN\/IEC 60947-2, and is suitable for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74201\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P (2 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 1 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6,000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 50 kA at 220-415 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 50 kA 100% at 220-415 V AC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1...25 mm² rigid \/ 1...16 mm² flexible, strip length 14 mm, torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eQuality mark: NF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic C curve trip unit delivers reliable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbars (upper or lower), simplifying distribution board assembly\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator enable fast visual fault diagnosis\u003c\/li\u003e\n  \u003cli\u003eApproved for use as an isolator, removing the need for a separate isolation device\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C suits demanding industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of low-current lighting and socket-outlet circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and machine protection\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery storage installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74201, Schneider Electric A9F74201, iC60N 2P 1A C curve MCB, Acti 9 miniature circuit breaker 1A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075308482824,"sku":"SCHA9F74201","price":17.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9f74201-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60n-2p-1a-c-curve-6000a-iecen-60898-1-50ka-iecen-60947-2-6666383.jpg?v=1757426448"},{"product_id":"a9f74216-ic60n-miniature-circuit-breaker-2p-16a-c-curve","title":"Schneider A9F74216 Acti9 iC60N MCB 2P 16 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74216 is a 2-pole Miniature Circuit Breaker (MCB) from the Acti 9 iC60N range, rated 16 A with a C tripping curve. It provides thermomagnetic overcurrent and short-circuit protection for AC and DC networks, with a breaking capacity of 10 kA Icu at 380...415 V AC per IEC 60947-2.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74216\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC (IEC 60898-1); 10 kA Icu at 380...415 V AC; 20 kA Icu at 220...240 V AC (IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (fixed)\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1...25 mm² rigid \/ 1...16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection for dependable overcurrent and short-circuit fault detection on AC and DC networks\u003c\/li\u003e\n  \u003cli\u003eC tripping curve suitable for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimizes let-through energy to protect downstream equipment\u003c\/li\u003e\n  \u003cli\u003eBusbar comb distributor block compatible (upper or lower) for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eTrip indicator and contact position indicator for fast local fault diagnosis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels complying with IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLighting, heating, and general power circuit protection\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems up to 125 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74216, Schneider Electric A9F74216, iC60N 2P 16A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075308908808,"sku":"SCHA9F74216","price":7.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74216-ic60n-miniature-circuit-breaker-2p-16a-c-curve-338839.jpg?v=1735230417"},{"product_id":"a9f74220-miniature-circuit-breaker-mcb-acti9-ic60n-2p-20a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74220 Acti9 iC60N MCB 2P 20 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74220 is a 2-pole, 20 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical power distribution. It features a C tripping curve with thermomagnetic protection and a rated ultimate breaking capacity of 10 kA at 380-415 V AC, supporting both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74220\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6,000 A at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icu]: 10 kA at 380-415 V AC; 20 kA at 220-240 V AC; 6 kA at 440 V AC; 10 kA at 125 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent magnetic threshold: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUsage category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (fixed)\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm; tightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports both AC and DC networks, extending installation flexibility\u003c\/li\u003e\n  \u003cli\u003eThermomagnetic protection with C curve for reliable overload and short-circuit tripping\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 minimises energy let-through during fault conditions\u003c\/li\u003e\n  \u003cli\u003eBuilt-in trip indicator provides immediate local fault signalling\u003c\/li\u003e\n  \u003cli\u003eTop or bottom comb busbar distribution block compatible for fast panel assembly\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C suits demanding installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panel and machine protection\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in off-grid and backup power systems\u003c\/li\u003e\n  \u003cli\u003eSub-distribution and feeder protection in building electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74220, Schneider Electric A9F74220, iC60N 2P 20A MCB, Acti9 miniature circuit breaker 20A C curve.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075308974344,"sku":"SCHA9F74220","price":8.43,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74220-miniature-circuit-breaker-mcb-acti9-ic60n-2p-20a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-184943.jpg?v=1735230417"},{"product_id":"a9f74225-miniature-circuit-breaker-mcb-acti9-ic60n-2p-25a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74225 Acti9 iC60N MCB 2P 25 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74225 is a 2-pole 25 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for electrical energy distribution. It features a C tripping curve and a breaking capacity of 10 kA at 380-415 V AC, making it suitable for both AC and DC network applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74225\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC 50\/60 Hz (IEC\/EN 60898-1); 10 kA Icu at 380-415 V AC 50\/60 Hz (IEC\/EN 60947-2); 10 kA Icu at up to 125 V DC (IEC\/EN 60947-2); 20 kA Icu at 220-240 V AC 50\/60 Hz (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (IEC\/EN 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV (IEC\/EN 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, IEC 60947-2, EN 60898-1, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for isolation per IEC\/EN 60898-1 and IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom connection)\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for rapid fault identification\u003c\/li\u003e\n  \u003cli\u003eHandle-operated control with contact position indicator\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 rated, suitable for industrial environments\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category IV, tropicalization class 2 per IEC 60068-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in AC and DC electrical panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panel wiring and sub-distribution\u003c\/li\u003e\n  \u003cli\u003eMotor and equipment circuit protection in industrial automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74225, Schneider Electric A9F74225, iC60N 2P 25A C curve MCB, Acti 9 miniature circuit breaker 25A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075309072648,"sku":"SCHA9F74225","price":9.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74225-miniature-circuit-breaker-mcb-acti9-ic60n-2p-25a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-184538.jpg?v=1735230419"},{"product_id":"a9f74232-ic60n-miniature-circuit-breaker-2p-32a-c-curve","title":"Schneider A9F74232 Acti9 iC60N MCB 2P 32 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74232 is a 2-pole 32 A miniature circuit breaker (MCB) from the Acti 9 iC60N series, designed for electrical power distribution. With a C tripping curve and a breaking capacity of 10 kA at 380-415 V AC, it provides reliable thermomagnetic overcurrent protection for both AC and DC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74232\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 32 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC 50\/60 Hz (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC 50\/60 Hz (EN\/IEC 60947-2); 20 kA Icu at 220-240 V AC 50\/60 Hz; 10 kA Icu at 72-125 V DC\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA (75%) at 380-415 V AC; 15 kA (75%) at 220-240 V AC\u003c\/li\u003e\n  \u003cli\u003eOvercurrent limiting: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm | Height: 85 mm | Depth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-35 mm² solid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic trip unit provides both overload and short-circuit protection in a single compact device\u003c\/li\u003e\n  \u003cli\u003eC tripping curve suited for loads with moderate inrush currents\u003c\/li\u003e\n  \u003cli\u003eCompatible with AC and DC networks for flexible installation\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for fast fault diagnosis\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible (top or bottom) for efficient panel wiring\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy, protecting downstream equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and general power circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring AC and DC circuit protection\u003c\/li\u003e\n  \u003cli\u003eSwitchboards where compact DIN rail MCBs are required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74232, Schneider Electric A9F74232, iC60N 2P 32A C curve MCB, Acti9 32A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075309138184,"sku":"SCHA9F74232","price":9.44,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/schneider-electric-a9f74232-32a-2-pole-miniature-circuit-breaker-mcb-400v-type-c-curve-3439574.jpg?v=1757426449"},{"product_id":"a9f74240-miniature-circuit-breaker-mcb-acti9-ic60n-2p-40a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74240 Acti9 iC60N MCB 2P 40 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74240 is a 2-pole 40 A miniature circuit breaker (MCB) from the Acti 9 iC60N range, designed for power distribution in AC and DC networks. It features a C tripping curve with thermomagnetic protection and delivers an ultimate breaking capacity of 10 kA at 380-415 V AC per IEC\/EN 60947-2, making it suitable for final distribution boards in residential, commercial, and light industrial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74240\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 10 kA at 380-415 V AC; 20 kA at 220-240 V AC; 36 kA at 12-133 V AC; 10 kA at 72-125 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7.5 kA at 380-415 V AC; 15 kA at 220-240 V AC; 4.5 kA at 440 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limiting: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation: Yes per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eComb busbar connection: Upper or lower\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible (upper or lower terminal)\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection unit provides dependable overcurrent and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering installation flexibility\u003c\/li\u003e\n  \u003cli\u003eCertified for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eIntegrated trip indicator and contact position indicator allow quick visual status checks\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbars (upper or lower) for efficient panel wiring\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C suits demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and automation enclosures\u003c\/li\u003e\n  \u003cli\u003eProtection of AC and DC circuits in switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eSupplementary circuit protection in motor control centers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74240, Schneider Electric A9F74240, iC60N 2P 40A MCB, Acti9 40 amp C curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075309302024,"sku":"SCHA9F74240","price":8.92,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74240-miniature-circuit-breaker-mcb-acti9-ic60n-2p-40a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-718217.jpg?v=1735230419"},{"product_id":"a9f74250-miniature-circuit-breaker-mcb-acti9-ic60n-2p-50a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74250 Acti9 iC60N MCB 2P 50 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74250 is a 2-pole, 50 A miniature circuit breaker from the Acti 9 iC60N range, featuring a C tripping curve and thermomagnetic protection for AC and DC networks. It achieves 10 kA Icu at 380-415 V AC per IEC 60947-2 and 6000 A Icn at 400 V AC per IEC 60898-1, suitable for residential and industrial distribution panel applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74250\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort designation: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 50 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 10 kA at 380-415 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 20 kA at 220-240 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible (upper or lower terminal)\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, IEC 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eApproved for use as an isolating device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for clear local status monitoring\u003c\/li\u003e\n  \u003cli\u003eComb busbar compatible, upper or lower connection, 9 mm pitch, 4 rows\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 for effective short-circuit current limitation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eCircuit protection in industrial control and automation panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in low-voltage control systems up to 125 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, IEC 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74250, Schneider Electric A9F74250, iC60N 2P 50A C curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075309367560,"sku":"SCHA9F74250","price":16.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f74250-miniature-circuit-breaker-mcb-acti9-ic60n-2p-50a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-217999.jpg?v=1735230417"},{"product_id":"a9f74263-miniature-circuit-breaker-mcb-acti9-ic60n-2p-63a-c-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2","title":"Schneider A9F74263 Acti9 iC60N MCB 2P 63 A C Curve 10kA","description":"\u003cp\u003eThe Schneider Electric A9F74263 is an Acti 9 iC60N 2-pole miniature circuit breaker (MCB) rated at 63 A with a C tripping curve, designed for electrical power distribution applications. It features thermomagnetic protection technology and supports both AC and DC network types. With a breaking capacity of 10 kA at 380-415 V AC (per IEC\/EN 60947-2), it delivers reliable overcurrent protection for downstream circuits.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F74263\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60N\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 63 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 6000 A Icn at 400 V AC 50\/60 Hz (EN\/IEC 60898-1); 10 kA Icu at 380-415 V AC 50\/60 Hz (EN\/IEC 60947-2); 10 kA Icu at \u0026lt;= 125 V DC (EN\/IEC 60947-2); 20 kA Icu at 220-240 V AC 50\/60 Hz (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7.5 kA at 380-415 V AC; 15 kA at 220-240 V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60898-1, EN 60898-1, IEC 60947-2, EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve suited for loads with moderate inrush currents, reducing nuisance tripping\u003c\/li\u003e\n  \u003cli\u003eSupports both AC and DC networks, providing flexibility across installation types\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator for quick local status verification\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 rating and overvoltage category IV for demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring reliable branch circuit protection\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic or battery-backed systems up to 125 V DC\u003c\/li\u003e\n  \u003cli\u003eSub-distribution switchboards in light industrial facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F74263, Schneider Electric A9F74263, iC60N 2P 63A C curve MCB, Acti9 63A miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075309465864,"sku":"SCHA9F74263","price":18.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9f74263-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60n-2p-63a-c-curve-6000a-iecen-60898-1-10ka-iecen-60947-2-9243257.jpg?v=1757426448"},{"product_id":"a9k24220-miniature-circuit-breaker-mcb-acti9-ik60n-2p-20a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K24220 Acti9 iK60N MCB 2P 20 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K24220 is a 2-pole miniature circuit breaker (MCB) from the Acti9 iK60N range, rated at 20 A with a C tripping curve and 6000 A breaking capacity at 400 V AC, designed for distribution applications in AC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24220\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iK60N\u003c\/li\u003e\n  \u003cli\u003eApplication: Distribution\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 20 A at 30 °C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5-10 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000 A (100% x Icn) at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection pitch: 18 mm between phases\u003c\/li\u003e\n  \u003cli\u003eConnection type: Tunnel type terminal (top or bottom), rigid 1-25 mm², flexible 1-16 mm²\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 200 g\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eLocking options: Padlocking device\u003c\/li\u003e\n  \u003cli\u003eColour: White\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermal-magnetic trip unit provides reliable overload and short-circuit protection for standard distribution loads.\u003c\/li\u003e\n  \u003cli\u003e6000 A breaking capacity (Icn) with 100% rated service breaking capacity (Ics) ensures robust fault protection.\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting simplifies installation and panel assembly.\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1, enabling safe maintenance and lockout procedures via optional padlocking device.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 60 °C supports use in demanding environments.\u003c\/li\u003e\n  \u003cli\u003eAccepts both rigid (up to 25 mm²) and flexible (up to 16 mm²) conductors for flexible wiring options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eSub-distribution panels in industrial and tertiary installations.\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting, socket, and general-purpose AC circuits at 400 V.\u003c\/li\u003e\n  \u003cli\u003eControl panel assemblies requiring DIN rail-mounted overcurrent protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 iK60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24220, Schneider Electric A9K24220, Acti9 iK60N 2P 20A MCB, Schneider 20A C curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075519049992,"sku":"SCHA9K24220","price":6.36,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k24220-miniature-circuit-breaker-mcb-acti9-ik60n-2p-20a-c-curve-6000a-iecen-60898-1-339645.jpg?v=1735230890"},{"product_id":"a9k24225-miniature-circuit-breaker-mcb-acti9-ik60n-2p-25a-c-curve-6000a-iec-en-60898-1","title":"Schneider A9K24225 Acti9 iK60N MCB 2P 25 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K24225 is a 2-pole miniature circuit breaker (MCB) from the Acti9 iK60N range, rated at 25 A with a C tripping curve and 6000 A breaking capacity at 400 V AC. Designed for distribution applications, it provides reliable thermal-magnetic overcurrent protection on AC networks conforming to EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24225\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iK60N\u003c\/li\u003e\n  \u003cli\u003eApplication: Distribution\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A at 30 °C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000 A (100% x Icn) at 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel type terminal (top or bottom), rigid 1...25 mm², flexible 1...16 mm²\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eConnection pitch: 18 mm between phases\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85 °C\u003c\/li\u003e\n  \u003cli\u003eWeight: 200 g\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit provides protection against both overload and short-circuit currents\u003c\/li\u003e\n  \u003cli\u003eC tripping curve suited for loads with moderate inrush currents such as lighting and distribution circuits\u003c\/li\u003e\n  \u003cli\u003e6000 A breaking capacity (Icn) with 100% rated service breaking capacity (Ics) ensures full protection in demanding installations\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation conforming to EN\/IEC 60898-1, eliminating need for a separate isolator\u003c\/li\u003e\n  \u003cli\u003ePadlocking device option available for lockout\/tagout safety procedures\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25...60 °C) supports use in harsh environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in industrial distribution panels\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and general-purpose AC distribution loads\u003c\/li\u003e\n  \u003cli\u003eDIN rail installations requiring compact 2-pole overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 iK60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24225, Schneider Electric A9K24225, Acti9 iK60N 2P 25A MCB, Schneider 25A C curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075519836424,"sku":"SCHA9K24225","price":6.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9k24225-miniature-circuit-breaker-mcb-acti9-ik60n-2p-25a-c-curve-6000a-iecen-60898-1-299723.jpg?v=1745850999"},{"product_id":"a9k24240-miniature-circuit-breaker-ik60n-2p-40-a-c-curve","title":"Schneider A9K24240 Acti9 iK60N MCB 2P 40 A C Curve 6kA DIN Rail","description":"\u003cp\u003eThe Schneider Electric A9K24240 is a 2-pole miniature circuit breaker (MCB) from the Acti9 iK60N range, rated at 40 A with a C tripping curve and 6000 A breaking capacity at 400 V AC. Designed for distribution applications, it provides thermal-magnetic overcurrent protection on AC networks with a magnetic tripping range of 5 to 10 x In.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24240\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iK60N\u003c\/li\u003e\n  \u003cli\u003eApplication: Distribution\u003c\/li\u003e\n  \u003cli\u003ePoles: 2P (2 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A at 30 °C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5 to 10 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000 A at 400 V AC conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000 A (100% x Icn) at 400 V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection pitch: 18 mm between phases\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type (top or bottom), rigid 1 to 35 mm², flexible 1 to 25 mm²\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 conforming to IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 200 g\u003c\/li\u003e\n  \u003cli\u003eColour: White\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: SNI\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes, conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFull 6000 A rated service breaking capacity (100% Ics) ensures reliable protection without derating.\u003c\/li\u003e\n  \u003cli\u003eC curve thermal-magnetic trip unit provides protection against overloads and short circuits in distribution circuits.\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation duty, eliminating the need for a separate disconnector.\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting with padlocking option for secure installation and lockout\/tagout capability.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25 to 60 °C suits demanding installation environments.\u003c\/li\u003e\n  \u003cli\u003eAccepts rigid conductors up to 35 mm² and flexible conductors up to 25 mm² for installation flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings.\u003c\/li\u003e\n  \u003cli\u003eSub-distribution panels requiring overcurrent protection on 400 V AC three-phase systems.\u003c\/li\u003e\n  \u003cli\u003eProtection of distribution circuits in industrial control panels and switchboards.\u003c\/li\u003e\n  \u003cli\u003eApplications requiring a device suitable for isolation without additional disconnection equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 iK60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24240, Schneider Electric A9K24240, Acti9 iK60N 2P 40A MCB, Schneider 40A C curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075520229640,"sku":"SCHA9K24240","price":8.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k24240-miniature-circuit-breaker-ik60n-2p-40-a-c-curve-882128.jpg?v=1735230890"},{"product_id":"419155-legrand-rx-miniature-circuit-breaker-2p-b6a-10ka","title":"Legrand 419155 MCB RX³ 2P 6A Curve B 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419155 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 6 A on the B tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419155\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970366931\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: B (3-5 In, 18-30 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: B\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 6 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419155, 419155, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461605945608,"sku":"LGR419155","price":6.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419155-legrand-rx3-miniature-circuit-breaker-2p-b6a-10ka-1182222.jpg?v=1762120027"},{"product_id":"419156-legrand-rx-miniature-circuit-breaker-2p-b10a-10ka","title":"Legrand 419156 MCB RX³ 2P 10A Curve B 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419156 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 10 A on the B tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419156\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970366962\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: B (3-5 In, 30-50 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: B\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 10 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419156, 419156, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461606109448,"sku":"LGR419156","price":5.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419156-legrand-rx3-miniature-circuit-breaker-2p-b10a-10ka-9827777.jpg?v=1762119998"},{"product_id":"419158-legrand-rx-miniature-circuit-breaker-2p-b16a-10ka","title":"Legrand 419158 MCB RX³ 2P 16A Curve B 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419158 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 16 A on the B tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419158\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367020\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: B (3-5 In, 48-80 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: B\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 16 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419158, 419158, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461606207752,"sku":"LGR419158","price":5.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419158-legrand-rx3-miniature-circuit-breaker-2p-b16a-10ka-4710599.jpg?v=1762120031"},{"product_id":"419159-legrand-rx-miniature-circuit-breaker-2p-b20a-10ka","title":"Legrand 419159 MCB RX³ 2P 20A Curve B 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419159 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 20 A on the B tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419159\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367051\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: B (3-5 In, 60-100 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: B\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 20 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 20 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419159, 419159, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461606797576,"sku":"LGR419159","price":5.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419159-legrand-rx3-miniature-circuit-breaker-2p-b20a-10ka-7282423.jpg?v=1762120000"},{"product_id":"419160-legrand-rx-miniature-circuit-breaker-2p-b25a-10ka","title":"Legrand 419160 MCB RX³ 2P 25A Curve B 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419160 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 25 A on the B tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419160\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367082\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: B (3-5 In, 75-125 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: B\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 25 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419160, 419160, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461606895880,"sku":"LGR419160","price":5.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419160-legrand-rx3-miniature-circuit-breaker-2p-b25a-10ka-5496164.jpg?v=1762120030"},{"product_id":"419161-legrand-rx-miniature-circuit-breaker-2p-b32a-10ka","title":"Legrand 419161 MCB RX³ 2P 32A Curve B 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419161 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 32 A on the B tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419161\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367112\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: B (3-5 In, 96-160 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: B\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 32 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 32 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419161, 419161, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461606994184,"sku":"LGR419161","price":6.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419161-legrand-rx3-miniature-circuit-breaker-2p-b32a-10ka-8238655.jpg?v=1762120032"},{"product_id":"419162-legrand-rx-miniature-circuit-breaker-2p-b40a-10ka","title":"Legrand 419162 MCB RX³ 2P 40A Curve B 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419162 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 40 A on the B tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419162\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367143\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: B (3-5 In, 120-200 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: B\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 40 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419162, 419162, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461607158024,"sku":"LGR419162","price":7.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419162-legrand-rx3-miniature-circuit-breaker-2p-b40a-10ka-2514268.jpg?v=1762119997"},{"product_id":"419163-legrand-rx-miniature-circuit-breaker-2p-b50a-10ka","title":"Legrand 419163 MCB RX³ 2P 50A Curve B 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419163 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 50 A on the B tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419163\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367174\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: B (3-5 In, 150-250 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: B\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 50 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003eVoltage type: AC\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 50 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419163, 419163, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461607256328,"sku":"LGR419163","price":9.27,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419163-legrand-rx3-miniature-circuit-breaker-2p-b50a-10ka-5707798.jpg?v=1762119997"},{"product_id":"419164-legrand-rx-miniature-circuit-breaker-2p-b63a-10ka","title":"Legrand 419164 MCB RX³ 2P 63A Curve B 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419164 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 63 A on the B tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419164\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367204\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: B (3-5 In, 189-315 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: B\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 63 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 63 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419164, 419164, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461608173832,"sku":"LGR419164","price":9.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419164-legrand-rx3-miniature-circuit-breaker-2p-b63a-10ka-8928508.jpg?v=1762120028"},{"product_id":"419221-legrand-rx-miniature-circuit-breaker-2p-c6a-10ka","title":"Legrand 419221 MCB RX³ 2P 6A Curve C 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419221 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 6 A on the C tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419221\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367730\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: C (5-10 In, 30-60 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: C\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 6 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 6 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419221, 419221, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461610139912,"sku":"LGR419221","price":6.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419221-legrand-rx3-miniature-circuit-breaker-2p-c6a-10ka-9926968.jpg?v=1762119999"},{"product_id":"419222-legrand-rx-miniature-circuit-breaker-2p-c10a-10ka","title":"Legrand 419222 MCB RX³ 2P 10A Curve C 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419222 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 10 A on the C tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419222\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367761\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: C (5-10 In, 50-100 A)\u003c\/li\u003e\n\u003cli\u003eRated current (In): 10 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003eenergy limitation class: Class 3 (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 10 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419222, 419222, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461610172680,"sku":"LGR419222","price":5.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419222-legrand-rx3-miniature-circuit-breaker-2p-c10a-10ka-7654313.jpg?v=1762120028"},{"product_id":"419224-legrand-rx-miniature-circuit-breaker-2p-c16a-10ka","title":"Legrand 419224 MCB RX³ 2P 16A Curve C 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419224 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 16 A on the C tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419224\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367822\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: C (5-10 In, 80-160 A)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 16 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003eenergy limitation class: Class 3 (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 16 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419224, 419224, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461610205448,"sku":"LGR419224","price":5.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419224-legrand-rx3-miniature-circuit-breaker-2p-c16a-10ka-9383913.jpg?v=1762119996"},{"product_id":"419225-legrand-rx-miniature-circuit-breaker-2p-c20a-10ka","title":"Legrand 419225 MCB RX³ 2P 20A Curve C 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419225 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 20 A on the C tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419225\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367853\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: C (5-10 In, 100-200 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: C\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 20 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 20 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419225, 419225, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461610238216,"sku":"LGR419225","price":5.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419225-legrand-rx3-miniature-circuit-breaker-2p-c20a-10ka-5997403.jpg?v=1762120029"},{"product_id":"419226-legrand-rx-miniature-circuit-breaker-2p-c25a-10ka","title":"Legrand 419226 MCB RX³ 2P 25A Curve C 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419226 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 25 A on the C tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419226\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367884\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: C (5-10 In, 125-250 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: C\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003erated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003erated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 25 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419226, 419226, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461610500360,"sku":"LGR419226","price":5.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419226-legrand-rx3-miniature-circuit-breaker-2p-c25a-10ka-3449067.jpg?v=1762119997"},{"product_id":"419227-legrand-rx-miniature-circuit-breaker-2p-c32a-10ka","title":"Legrand 419227 MCB RX³ 2P 32A Curve C 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419227 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 32 A on the C tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419227\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367914\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: C (5-10 In, 160-320 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: C\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 32 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 32 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419227, 419227, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461610533128,"sku":"LGR419227","price":6.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419227-legrand-rx3-miniature-circuit-breaker-2p-c32a-10ka-4156456.jpg?v=1762119995"},{"product_id":"419228-legrand-rx-miniature-circuit-breaker-2p-c40a-10ka","title":"Legrand 419228 MCB RX³ 2P 40A Curve C 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419228 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 40 A on the C tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419228\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367945\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: C (5-10 In, 200-400 A)\u003c\/li\u003e\n\u003cli\u003erelease characteristic: C\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003erated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003erated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icu 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003eFlush-mountable: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 360-440 V\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eHalogen-free: No\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 40 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419228, 419228, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461610565896,"sku":"LGR419228","price":7.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419228-legrand-rx3-miniature-circuit-breaker-2p-c40a-10ka-4587465.jpg?v=1762120032"},{"product_id":"419229-legrand-rx-miniature-circuit-breaker-2p-c50a-10ka","title":"Legrand 419229 MCB RX³ 2P 50A Curve C 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419229 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 50 A on the C tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419229\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970367976\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: C (5-10 In, 250-500 A)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 50 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003erated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003erated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003eenergy limitation class: Class 3 (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 50 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419229, 419229, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461610598664,"sku":"LGR419229","price":8.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419229-legrand-rx3-miniature-circuit-breaker-2p-c50a-10ka-2227197.jpg?v=1762120031"},{"product_id":"419230-legrand-rx-miniature-circuit-breaker-2p-c63a-10ka","title":"Legrand 419230 MCB RX³ 2P 63A Curve C 6kA DIN Rail","description":"\u003cp\u003eThe Legrand 419230 is an RX³ miniature circuit breaker (MCB), 2-pole, rated 63 A on the C tripping curve, for 400 V installations. It has a short-circuit breaking capacity of 6 kA per IEC 60898-1, occupies 2 modules on a DIN rail, and provides overcurrent and short-circuit protection for residential and small-commercial distribution circuits.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 419230\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970368003\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 35.4 × 88.5 × 77.8 mm\u003c\/li\u003e\n\u003cli\u003ebreaking capacity: 6000 A (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003etripping curve: C (5-10 In, 315-630 A)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n\u003cli\u003eRated current (In): 63 A\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003erated insulation voltage: 500 V\u003c\/li\u003e\n\u003cli\u003erated impulse withstand voltage: 4 kV\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 230v: 10 kA\u003c\/li\u003e\n\u003cli\u003eshort circuit breaking capacity icn 400v: 6 kA\u003c\/li\u003e\n\u003cli\u003eFrequency: 50-60 Hz\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK02\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003eenergy limitation class: Class 3 (IEC 60898-1)\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThermal-magnetic tripping provides reliable protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eClass 3 energy limitation per IEC 60898-1 minimises let-through energy during a fault.\u003c\/li\u003e\n\u003cli\u003eAccepts copper cable, prong busbar, or fork busbar for flexible distribution-board assembly.\u003c\/li\u003e\n\u003cli\u003eCompact 1-module-per-pole footprint suits dense modular enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFinal circuit protection for residential and small-commercial distribution boards up to 63 A.\u003c\/li\u003e\n\u003cli\u003eLighting, socket-outlet and small-appliance feeders requiring C-curve tripping behaviour.\u003c\/li\u003e\n\u003cli\u003eSeries coordination with upstream RCDs in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eModular distribution enclosures conforming to IEC 60898-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 419230, 419230, RX³ LEGRAND.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":52461610631432,"sku":"LGR419230","price":9.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/419230-legrand-rx3-miniature-circuit-breaker-2p-c63a-10ka-4715409.jpg?v=1762120001"},{"product_id":"a9f84202-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c2a-10ka","title":"Schneider A9F84202 Miniature Circuit Breaker (MCB), Acti9 iC60H 2P C2A 10kA","description":"\u003cp\u003eThe Schneider Electric A9F84202 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 2A with a C tripping curve. Designed for electrical power distribution, it provides thermomagnetic protection with a 10kA breaking capacity at 400V AC, making it suitable for protecting circuits against overload and short-circuit faults.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84202\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eShort device name: iC60H\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 2A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10kA at 400V AC 50\/60Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 70kA at 220-240V AC 50\/60Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 70kA at 380-415V AC 50\/60Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 15kA at 72-125V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500V AC 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent limiting threshold: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25mm² rigid \/ 1-16mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, IEC 60898-1, EN 60947-2, EN 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 70kA at 380-415V AC provides robust short-circuit protection for demanding installations\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for quick visual fault identification at the panel\u003c\/li\u003e\n  \u003cli\u003eCompatible with busbar comb distribution blocks (top or bottom connection)\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-35 to 70°C) suits demanding industrial environments\u003c\/li\u003e\n  \u003cli\u003eNF quality mark certification ensures compliance with French national standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of low-current control and signalling circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring high breaking capacity protection\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic or battery-backed systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60947-2, IEC 60898-1, EN 60947-2, and EN 60898-1. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F84202, Schneider Electric A9F84202, Acti9 iC60H 2P C2A MCB, Schneider 2A C-curve circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952059674888,"sku":"SCHA9F84202","price":18.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f84202-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c2a-10ka-9605792.jpg?v=1765818552"},{"product_id":"a9f84206-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c6a-10ka","title":"Schneider A9F84206 Miniature Circuit Breaker (MCB), Acti9 iC60H 2P C6A 10kA","description":"\u003cp\u003eThe Schneider Electric A9F84206 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, providing thermomagnetic overload and short-circuit protection with a 10 kA rated breaking capacity at 400 V AC. Suitable for both AC and DC networks, it features a C tripping characteristic designed for standard resistive and slightly inductive loads in power distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84206\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60H\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 6 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eRated breaking capacity [Icn]: 10 kA at 400 V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 42 kA at 12-133 V AC; 30 kA at 220-240 V AC; 15 kA at 380-415 V AC; 10 kA at 440 V AC; 15 kA at up to 125 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 50% of Icu (AC); 100% at 72-125 V DC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eUse category: Category A (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eMounting: Fixed, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible; strip length 14 mm; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: IEC 60947-2, IEC 60898-1, EN 60947-2, EN 60898-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 10 kA at 400 V AC makes it suitable for demanding industrial and commercial distribution networks\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering installation flexibility across different system types\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear visual feedback on device status\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eIsolation-suitable design per EN\/IEC 60898-1 and EN\/IEC 60947-2, enabling use as a disconnecting device\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 ensures fast energy limitation, reducing let-through energy during faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings requiring high fault protection\u003c\/li\u003e\n  \u003cli\u003ePower distribution panels where both AC and DC circuit protection is needed\u003c\/li\u003e\n  \u003cli\u003eProtection of resistive and slightly inductive loads such as lighting circuits and general power outlets\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and automation enclosures requiring IEC 60947-2 compliant devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F84206, Schneider Electric A9F84206, iC60H 2P C6A MCB, Acti9 6A 2-pole circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952059805960,"sku":"SCHA9F84206","price":13.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f84206-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c6a-10ka-8401672.jpg?v=1765818613"},{"product_id":"a9f84210-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c10a-10ka","title":"A9F84210 Schneider MCB, Acti9 iC60H 2P C10A 10kA","description":"\u003cp\u003eThe Schneider Electric A9F84210 is a 2-pole Miniature Circuit Breaker (MCB) from the Acti 9 iC60H range, rated at 10 A with a C tripping characteristic. Using thermomagnetic protection technology, it safeguards both AC and DC circuits with a breaking capacity of 10 kA Icn at 400 V AC per IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84210\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eRated current: 10 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10 kA at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 30 kA at 220-240 V AC \/ 15 kA at 380-415 V AC \/ 10 kA at 440 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 7,500 A (75%) at 400 V AC per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eUtilization category: Category A per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, fixed\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35...70°C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-25 mm² rigid \/ 1-16 mm² flexible, tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection delivers reliable overload and short-circuit disconnection\u003c\/li\u003e\n  \u003cli\u003eC tripping curve suits loads with moderate inrush current such as lighting and general-purpose circuits\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolation device per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces thermal and mechanical stress on downstream wiring and equipment\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator allow quick visual status verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and socket outlet circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial switchboards and control panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in battery-backed or photovoltaic installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F84210, Schneider Electric A9F84210, iC60H 2P 10A C-curve MCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952059969800,"sku":"SCHA9F84210","price":12.63,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f84210-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c10a-10ka-1306998.jpg?v=1765818669"},{"product_id":"a9f84216-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c16a-10ka","title":"Schneider A9F84216 Miniature Circuit Breaker (MCB), Acti9 iC60H 2P C16A 10kA","description":"\u003cp\u003eThe Schneider Electric A9F84216 is a 2-pole Miniature Circuit Breaker (MCB) from the Acti 9 iC60H range, rated at 16 A with a C tripping characteristic. Designed for electrical power distribution, it delivers a breaking capacity of 10 kA at 400 V AC per EN\/IEC 60898-1, making it suitable for both AC and DC network applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84216\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60H\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current: 16 A\u003c\/li\u003e\n  \u003cli\u003eTripping characteristic: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 10 kA Icn at 400 V AC (EN\/IEC 60898-1); 30 kA Icu at 220-240 V AC; 15 kA Icu at 380-415 V AC; 10 kA Icu at 440 V AC; 15 kA Icu at 125 V DC (EN\/IEC 60947-2)\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity (Ics): 7,500 A (75%) at 400 V AC (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC\/EN 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² solid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 10 kA at 400 V AC suitable for demanding distribution applications\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for flexible installation\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indication for fast fault diagnosis\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks (top or bottom connection)\u003c\/li\u003e\n  \u003cli\u003ePollution degree 3 rating and overvoltage category IV for harsh environments\u003c\/li\u003e\n  \u003cli\u003eTropicalization rating (IEC 60068-1) for humid and tropical conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial electrical panels and power distribution switchgear\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery systems\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in main and sub-distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F84216, Schneider Electric A9F84216, iC60H 2P C16A MCB, Acti9 16A 2-pole circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952060100872,"sku":"SCHA9F84216","price":12.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f84216-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c16a-10ka-7295236.jpg?v=1765818610"},{"product_id":"a9f84220-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c20a-10ka","title":"Schneider A9F84220 Miniature Circuit Breaker (MCB), Acti9 iC60H 2P C20A 10kA","description":"\u003cp\u003eThe Schneider Electric A9F84220 is a 2-pole, 20 A Miniature Circuit Breaker (MCB) from the Acti 9 iC60H series, featuring a C tripping curve and thermomagnetic protection technology. Suitable for both AC and DC networks, it delivers a 10 kA breaking capacity at 400 V AC per IEC 60898-1 and up to 30 kA at 220-240 V AC per IEC 60947-2, making it well suited to demanding distribution applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84220\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P (2 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current: 20 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10 kA at 400 V AC per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 15 kA at 380-415 V AC; 30 kA at 220-240 V AC; 42 kA at 12-133 V AC; 15 kA at DC up to 125 V per IEC\/EN 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per IEC\/EN 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent trip threshold: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (fixed)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 36 x 85 x 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-25 mm² rigid \/ 1-16 mm² flexible; tightening torque 2 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3; overvoltage category IV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection guards against both overloads and short circuits on AC and DC networks\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 enables fast current limiting, reducing thermal and mechanical stress on the installation\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbars on upper or lower terminals for flexible panel wiring\u003c\/li\u003e\n  \u003cli\u003eBuilt-in contact position indicator and trip indicator for immediate visual status confirmation\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -35 to 70°C for use in harsh or outdoor enclosure environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring reliable overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems up to 125 V DC\u003c\/li\u003e\n  \u003cli\u003eLow-voltage switchgear and controlgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 60898-1, EN 60898-1, IEC 60947-2, and EN 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F84220, Schneider Electric A9F84220, iC60H 2P C20A MCB, Acti9 miniature circuit breaker 20A 2 pole.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952060199176,"sku":"SCHA9F84220","price":13.41,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f84220-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c20a-10ka-7873509.jpg?v=1765818553"},{"product_id":"a9f84225-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-cc25a-10ka","title":"Schneider A9F84225 Miniature Circuit Breaker (MCB), Acti9 iC60H 2P Cc25A 10kA","description":"\u003cp\u003eThe Schneider Electric A9F84225 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 25 A with a C tripping characteristic. It provides thermomagnetic overcurrent protection for AC and DC distribution circuits, with a breaking capacity of 10,000 A at 400 V AC per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84225\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60H\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 10,000 A at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icu): 30 kA at 220-240 V AC \/ 15 kA at 380-415 V AC \/ 10 kA at 440 V AC \/ 15 kA at \u0026lt;=125 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 6 kV\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC tripping curve suits circuits with moderate inrush loads such as lighting and distribution panels\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks for versatile installation scenarios\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2, eliminating the need for a separate isolator\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting with comb busbar compatibility (top or bottom) for fast and flexible panel assembly\u003c\/li\u003e\n  \u003cli\u003eTrip indicator provides local signalling for quick fault identification\u003c\/li\u003e\n  \u003cli\u003eLimitation class 3 reduces let-through energy, protecting downstream equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring reliable overcurrent protection\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting circuits and general-purpose AC distribution feeders\u003c\/li\u003e\n  \u003cli\u003eDC distribution systems requiring breaking capacity up to 15 kA at 125 V DC\u003c\/li\u003e\n  \u003cli\u003eSwitchboard assemblies where comb busbar connection is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F84225, Schneider Electric A9F84225, iC60H 2P 25A MCB, Acti9 miniature circuit breaker 25A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952060494088,"sku":"SCHA9F84225","price":13.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f84225-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-cc25a-10ka-2912679.jpg?v=1765818608"},{"product_id":"a9f84240-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c40a-10ka","title":"Schneider A9F84240 Miniature Circuit Breaker (MCB), Acti9 iC60H 2P C40A 10kA","description":"\u003cp\u003eThe Schneider Electric A9F84240 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 40 A with a C tripping curve. It provides thermomagnetic overcurrent protection for AC and DC distribution networks, with a breaking capacity of 10 kA Icn at 400 V AC per EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9F84240\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iC60\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iC60H\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC \/ DC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10 kA at 400 V AC 50\/60 Hz per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eUltimate breaking capacity [Icu]: 30 kA at 220-240 V AC \/ 15 kA at 380-415 V AC \/ 10 kA at 440 V AC \/ 15 kA at ≤125 V DC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eService breaking capacity [Ics]: 15 kA at 220-240 V AC \/ 7.5 kA at 380-415 V AC \/ 5 kA at 440 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 per EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 8 x In +\/- 20%\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.25 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block (top or bottom), 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 per IEC\/EN 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -35 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3 per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColour: White\u003c\/li\u003e\n  \u003cli\u003eStandards: EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermomagnetic protection technology provides reliable overload and short-circuit protection in a compact 2-module width\u003c\/li\u003e\n  \u003cli\u003eHigh breaking capacity of 10 kA Icn at 400 V AC makes it suitable for demanding industrial and commercial distribution applications\u003c\/li\u003e\n  \u003cli\u003eCompatible with both AC and DC networks, offering application flexibility\u003c\/li\u003e\n  \u003cli\u003eComb busbar distribution block compatible (top or bottom), simplifying panel wiring\u003c\/li\u003e\n  \u003cli\u003eTrip indicator for quick visual fault identification, with contact position indicator\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation per EN\/IEC 60898-1 and EN\/IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in commercial and industrial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in low-voltage switchboards and panel boards\u003c\/li\u003e\n  \u003cli\u003eMotor and equipment protection in industrial automation panels\u003c\/li\u003e\n  \u003cli\u003eDC circuit protection in photovoltaic and battery systems\u003c\/li\u003e\n  \u003cli\u003eSub-distribution in infrastructure and tertiary sector installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN 60898-1, EN 60947-2, IEC 60898-1, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9F84240, Schneider Electric A9F84240, Acti9 iC60H 2P C40A MCB, Schneider 40A 2-pole circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952060625160,"sku":"SCHA9F84240","price":17.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9f84240-schneider-electric-miniature-circuit-breaker-mcb-acti9-ic60h-2p-c40a-10ka-7852326.jpg?v=1765818551"},{"product_id":"a9k24210-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-2p-c10a-6ka","title":"Schneider A9K24210 Miniature Circuit Breaker (MCB), Acti9 iK60N 2P C10A 6kA","description":"\u003cp\u003eThe Schneider Electric A9K24210 is a 2-pole miniature circuit breaker (MCB) from the Acti9 iK60N series, rated at 10A with a C tripping curve and 6000A breaking capacity at 400V AC. Designed for distribution applications, it provides reliable thermal-magnetic overcurrent protection on AC networks conforming to EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24210\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eDevice short name: iK60N\u003c\/li\u003e\n  \u003cli\u003eApplication: Distribution\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10A at 30°C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5...10 x In\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000A at 400V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000A (100% x Icn) at 400V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35 mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection pitch: 18 mm between phases\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type (top or bottom), rigid 1...25 mm², flexible 1...16 mm²\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection rating: IP20 (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85°C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 85 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 78.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 200 g\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eSuitability for isolation: Yes (EN\/IEC 60898-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermal-magnetic trip unit provides reliable protection against overload and short-circuit currents in distribution circuits\u003c\/li\u003e\n  \u003cli\u003e6000A breaking capacity (Icn) with 100% rated service breaking capacity (Ics) at 400V AC\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting for fast, tool-free installation in standard enclosures\u003c\/li\u003e\n  \u003cli\u003eTunnel-type terminals accept rigid conductors up to 25 mm², simplifying field wiring\u003c\/li\u003e\n  \u003cli\u003ePadlocking device option allows locking in open or closed position for safety and maintenance\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range of -25...60°C suits demanding installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of branch circuits in industrial distribution panels\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in control panels and switchboards\u003c\/li\u003e\n  \u003cli\u003eDIN rail assemblies requiring compact 2-pole MCB protection at 10A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 iK60 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24210, Schneider Electric A9K24210, iK60N 2P C10A MCB, Acti9 10A 2-pole circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952061772040,"sku":"SCHA9K24210","price":6.16,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k24210-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-2p-c10a-6ka-2546633.jpg?v=1765818613"},{"product_id":"a9k24216-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-2p-c16a-6ka","title":"Schneider A9K24216 Miniature Circuit Breaker (MCB), Acti9 iK60N 2P C16A 6kA","description":"\u003cp\u003eThe Schneider Electric A9K24216 is a 2-pole miniature circuit breaker (MCB) from the Acti9 iK60N series, rated at 16A with a C tripping curve and 6000A breaking capacity, designed for distribution applications in AC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9K24216\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti9 iK60N\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003ePoles: 2P (2 protected poles)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 16A at 30°C\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 400V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5-10 x In\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 6000A at 400V AC conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eRated service breaking capacity [Ics]: 6000A (100% x Icn) at 400V AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, 35mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eConnection pitch: 18mm between phases\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: Tunnel type (top or bottom), rigid 1-25 mm², flexible 1-16 mm²\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 14mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eWidth: 36mm | Height: 85mm | Depth: 78.5mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 200g\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 conforming to IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 60°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: II\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eLocking: Padlocking device compatible\u003c\/li\u003e\n  \u003cli\u003eColour: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFull 6000A rated service breaking capacity (100% Ics) ensures reliable fault protection without derating\u003c\/li\u003e\n  \u003cli\u003eSuitable for isolation conforming to EN\/IEC 60898-1, enabling safe maintenance procedures\u003c\/li\u003e\n  \u003cli\u003eThermal-magnetic trip unit with C curve provides reliable overload and short-circuit protection for resistive and light inductive loads\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting simplifies panel assembly and reduces installation time\u003c\/li\u003e\n  \u003cli\u003ePadlocking device compatibility allows locking in open or closed position for safety compliance\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25 to 60°C) suits demanding installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and general power circuits in electrical panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panel circuit protection for distribution applications\u003c\/li\u003e\n  \u003cli\u003eSub-distribution boards requiring reliable overcurrent and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Acti9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9K24216, Schneider Electric A9K24216, Acti9 iK60N 2P C16A MCB, Schneider 16A C curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952061837576,"sku":"SCHA9K24216","price":6.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9k24216-schneider-electric-miniature-circuit-breaker-mcb-acti9-ik60n-2p-c16a-6ka-9644765.jpg?v=1765818608"},{"product_id":"a9n18360-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120n-2p-c63a-10ka","title":"Schneider A9N18360 Miniature Circuit Breaker (MCB), Acti9 C120N 2P C63A 10kA","description":"\u003cp\u003eThe Schneider Electric A9N18360 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 C120N series, rated at 63 A with a C tripping characteristic. Designed for electrical power distribution, it provides thermomagnetic overcurrent protection with a breaking capacity of 10 kA at 230-400 V AC.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9N18360\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 C120\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 63 A at 30 °C\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eProtection unit technology: Thermomagnetic\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection limit: 5-10 x In\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 V AC \/ 380-415 V AC \/ 440 V AC 50\/60 Hz; ≤250 V DC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity [Icn]: 10 kA at 230-400 V AC per EN\/IEC 60898-1; 20 kA at 220-240 V AC, 10 kA at 380-415 V AC, 6 kA at 440 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 1 per EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eMounting: 35 mm symmetrical DIN rail, clip-on\u003c\/li\u003e\n  \u003cli\u003eWidth: 54 mm (6 x 9 mm modules)\u003c\/li\u003e\n  \u003cli\u003eHeight: 81 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.41 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 per IEC 60529\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eOperating altitude: up to 2000 m\u003c\/li\u003e\n  \u003cli\u003eConnection: Tunnel terminals, 1-50 mm² rigid \/ 1.5-35 mm² flexible; strip length 15 mm; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1, EN\/IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eCertifications: EAC\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 10000 cycles per IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh breaking capacity of 10 kA at rated voltage, suitable for demanding distribution applications\u003c\/li\u003e\n  \u003cli\u003eThermomagnetic trip unit provides reliable protection against both overload and short-circuit currents\u003c\/li\u003e\n  \u003cli\u003eHandle sealable with cable diameter 0.7 mm in OFF or ON position for tamper prevention\u003c\/li\u003e\n  \u003cli\u003eCompatible with comb busbar distribution blocks for simplified panel wiring\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides clear local ON\/OFF status reading\u003c\/li\u003e\n  \u003cli\u003eSuitable for use as an isolating device per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eIndustrial electrical panels requiring high breaking capacity protection\u003c\/li\u003e\n  \u003cli\u003ePower distribution switchboards at voltages up to 440 V AC\u003c\/li\u003e\n  \u003cli\u003eDC applications up to 250 V DC in renewable energy or battery systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1 and EN\/IEC 60947-2. Part of the Schneider Electric Acti 9 C120 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9N18360, Schneider Electric A9N18360, C120N 2P 63A MCB, Acti9 C120N C63A circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":52952062591240,"sku":"SCHA9N18360","price":41.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9n18360-schneider-electric-miniature-circuit-breaker-mcb-acti9-c120n-2p-c63a-10ka-5488009.jpg?v=1765818669"},{"product_id":"r9fec210-schneider-electric-miniature-circuit-breaker-mcb-resi9-xe-2p-c10a-3000a-230v","title":"Schneider R9FEC210 Miniature Circuit Breaker (MCB), Resi9 XE, 2P C10A 3000A 230V","description":"\u003cp\u003eThe Schneider Electric R9FEC210 is a 2-pole miniature circuit breaker (MCB) from the Resi9 XE series, rated at 10A with a C tripping curve and 3000A breaking capacity. Designed for distribution applications, it provides reliable thermal-magnetic overcurrent protection for AC networks at 230V, 50\/60Hz.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: R9FEC210\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Resi9 XE\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eApplication: Distribution\u003c\/li\u003e\n  \u003cli\u003ePoles: 2P, 2 protected poles, neutral position left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 10A at 30°C\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 230V AC 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4kV\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 3000A Icn at 230V AC conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5-10 x In AC\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 conforming to EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, DIN rail, 4 x 9mm pitches\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 89 x 71.2mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 208g\u003c\/li\u003e\n  \u003cli\u003eColour: White (RAL 9003)\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20; IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 40°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 80°C\u003c\/li\u003e\n  \u003cli\u003eConnection (top): Plug-in\u003c\/li\u003e\n  \u003cli\u003eConnection (bottom): Tunnel terminals - rigid 1-25mm², flexible 1-16mm², flexible with ferrule 1-16mm²\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 13mm (bottom connection)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: CE, CEBEC\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit provides reliable protection against overload and short-circuit conditions\u003c\/li\u003e\n  \u003cli\u003eC curve characteristic suitable for distribution circuits with standard inductive loads\u003c\/li\u003e\n  \u003cli\u003ePlug-in top connection simplifies installation and replacement in distribution boards\u003c\/li\u003e\n  \u003cli\u003eWide terminal acceptance (up to 25mm² rigid) accommodates various cable sizes\u003c\/li\u003e\n  \u003cli\u003eCompact 36mm width (4 x 9mm pitches) saves panel space in modular enclosures\u003c\/li\u003e\n  \u003cli\u003eON\/OFF local indication allows quick visual status check\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and light commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and socket outlet circuits in domestic installations\u003c\/li\u003e\n  \u003cli\u003eSub-distribution panels in apartments, offices, and small commercial premises\u003c\/li\u003e\n  \u003cli\u003eOvercurrent protection in modular DIN rail enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Resi9 XE range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider R9FEC210, Schneider Electric R9FEC210, Resi9 XE 2P C10A MCB, Schneider 2-pole 10A C-curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53107744801032,"sku":"SCHR9FEC210","price":16.61,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/r9fec210-schneider-electric-miniature-circuit-breaker-mcb-resi9-xe-2p-c10a-3000a-230v-6744820.png?v=1768101309"},{"product_id":"r9fec216-schneider-electric-miniature-circuit-breaker-mcb-resi9-xe-2p-c16a-3000a","title":"Schneider R9FEC216 Miniature Circuit Breaker (MCB), Resi9 XE, 2P C16A 3000A","description":"\u003cp\u003eThe Schneider Electric R9FEC216 is a 2-pole miniature circuit breaker (MCB) from the Resi9 XE range, rated at 16A with a C tripping curve. Designed for distribution applications, it delivers a breaking capacity of 3000A at 230V AC, conforming to EN\/IEC 60898-1.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: R9FEC216\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Resi9 XE\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eApplication: Distribution\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 16A at 30°C\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 3000A Icn at 230V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage [Ue]: 230V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5-10 x In AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, DIN rail\u003c\/li\u003e\n  \u003cli\u003eWidth: 36 mm (4 x 9 mm pitches)\u003c\/li\u003e\n  \u003cli\u003eHeight: 89 mm\u003c\/li\u003e\n  \u003cli\u003eDepth: 71.2 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 208 g\u003c\/li\u003e\n  \u003cli\u003eIP degree of protection: IP20 \/ IP40 (in modular enclosure)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 40°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 80°C\u003c\/li\u003e\n  \u003cli\u003eConnection (top): Plug-in\u003c\/li\u003e\n  \u003cli\u003eConnection (bottom): Tunnel terminals, 1-25 mm² rigid \/ 1-16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eColour: White (RAL 9003)\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: CE, CEBEC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eThermal-magnetic trip unit provides reliable overload and short-circuit protection in a compact 4-module width.\u003c\/li\u003e\n  \u003cli\u003eC curve characteristic suits distribution circuits with moderate inrush loads.\u003c\/li\u003e\n  \u003cli\u003ePlug-in top connection and tunnel-type bottom terminals accept rigid cables up to 25 mm², simplifying installation and wiring.\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting and ON\/OFF toggle indication enable fast, clear panel assembly.\u003c\/li\u003e\n  \u003cli\u003eRated for operation from -25 to 40°C with tropicalisation class 2, suitable for demanding environments.\u003c\/li\u003e\n  \u003cli\u003eWhite RAL 9003 finish with IP20 protection for open distribution boards, upgradeable to IP40 in a modular enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential buildings and apartments.\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical panels requiring reliable branch circuit protection.\u003c\/li\u003e\n  \u003cli\u003eSub-distribution boards in light industrial and tertiary installations.\u003c\/li\u003e\n  \u003cli\u003eProtection of lighting and general power circuits with standard inrush characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Resi9 XE range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider R9FEC216, Schneider Electric R9FEC216, Resi9 XE 2P C16A MCB, Schneider 2-pole 16A C curve miniature circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53107744932104,"sku":"SCHR9FEC216","price":12.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/r9fec216-schneider-electric-miniature-circuit-breaker-mcb-resi9-xe-2p-c16a-3000a-8377553.png?v=1768101372"},{"product_id":"r9fec220-schneider-electric-miniature-circuit-breaker-mcb-resi9-xe-2p-c20a-3000a","title":"Schneider R9FEC220 Miniature Circuit Breaker (MCB), Resi9 XE, 2P C20A 3000A","description":"\u003cp\u003eThe Schneider Electric R9FEC220 is a 2-pole miniature circuit breaker (MCB) from the Resi9 XE range, rated at 20A with a C tripping curve and 3000A breaking capacity per IEC\/EN 60898-1. Designed for distribution applications, it provides reliable thermal-magnetic overcurrent protection for AC networks at 230V.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: R9FEC220\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Resi9 XE\u003c\/li\u003e\n  \u003cli\u003eProduct type: Miniature circuit breaker (MCB)\u003c\/li\u003e\n  \u003cli\u003eApplication: Distribution\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNumber of protected poles: 2\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current: 20A at 30°C (EN\/IEC 60898)\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eTripping curve: C\u003c\/li\u003e\n  \u003cli\u003eTrip unit technology: Thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity: 3000A Icn at 230V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eRated operational voltage: 230V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage: 500V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage: 4 kV\u003c\/li\u003e\n  \u003cli\u003eMagnetic tripping limit: 5-10 x In AC\u003c\/li\u003e\n  \u003cli\u003eLimitation class: 3 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDIN rail pitches: 4 x 9 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 89 x 71.2 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 208 g\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 \/ IP40 (in modular enclosure, IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 40°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 80°C\u003c\/li\u003e\n  \u003cli\u003eConnection type: Plug-in (top); tunnel terminals (bottom) - up to 25 mm² rigid, up to 16 mm² flexible or flexible with ferrule\u003c\/li\u003e\n  \u003cli\u003eWire stripping length: 13 mm (bottom connection)\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 2 N.m\u003c\/li\u003e\n  \u003cli\u003eColour: White (RAL 9003)\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability: 10000 cycles at 230V AC 50\/60 Hz (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eEarth-leakage protection: Without\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2 (EN\/IEC 60898-1)\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: III\u003c\/li\u003e\n  \u003cli\u003eCertifications: CE, CEBEC\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 60898-1\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eC curve thermal-magnetic trip unit provides reliable protection against overloads and short circuits in distribution circuits with moderate inrush currents.\u003c\/li\u003e\n  \u003cli\u003e3000A breaking capacity at 230V AC meets IEC\/EN 60898-1 requirements for residential and light commercial distribution boards.\u003c\/li\u003e\n  \u003cli\u003ePlug-in top connection and tunnel-type bottom terminals accept conductors from 1 to 25 mm² rigid, simplifying installation and wiring flexibility.\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting with 4 x 9 mm pitch allows compact panel assembly and easy integration alongside other Resi9 modular devices.\u003c\/li\u003e\n  \u003cli\u003eOperating range of -25 to 40°C and tropicalisation class 2 (IEC 60068-1) ensure reliable performance across varied environmental conditions.\u003c\/li\u003e\n  \u003cli\u003eON\/OFF toggle indication provides clear local status signalling for safe operation and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential buildings requiring 2-pole overcurrent protection on 230V AC circuits.\u003c\/li\u003e\n  \u003cli\u003eLight commercial installations where C curve characteristics suit loads with moderate inrush, such as lighting and general socket circuits.\u003c\/li\u003e\n  \u003cli\u003eModular enclosure assemblies requiring compact DIN rail-mounted protection devices alongside RCDs or other Resi9 accessories.\u003c\/li\u003e\n  \u003cli\u003eSub-distribution panels in small commercial or industrial premises operating on single-phase 230V AC networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60898-1. Part of the Schneider Electric Resi9 XE range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider R9FEC220, Schneider Electric R9FEC220, Resi9 XE 2P 20A MCB, Schneider 2-pole miniature circuit breaker C20.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":53107745063176,"sku":"SCHR9FEC220","price":12.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/r9fec220-schneider-electric-miniature-circuit-breaker-mcb-resi9-xe-2p-c20a-3000a-6462813.png?v=1768101313"}],"url":"https:\/\/gabbyelectric.com\/en-us\/collections\/2-pole-mcb.oembed?page=3","provider":"Gabby Electric","version":"1.0","type":"link"}