Schneider A9F94110 Miniature Circuit Breaker (MCB), Acti9 iC60L, 1P C10A 15kA
Free Shipping
Get free shipping on orders exceeding €300!
Schneider Electric A9F94110 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60L range, rated at 10 A with a C tripping curve. Designed for electrical power distribution, it delivers a high breaking capacity of 15 kA at 230 V AC and up to 70 kA at 12-60 V AC, making it suitable for demanding installation environments.
Technical specifications:
- Commercial reference: A9F94110
- Manufacturer: Schneider Electric
- Series / range: Acti 9 iC60
- Device short name: iC60L
- Number of poles: 1P
- Number of protected poles: 1
- Rated current [In]: 10 A
- Tripping curve: C
- Network type: AC / DC
- Trip unit technology: Thermomagnetic
- Breaking capacity [Icn]: 15 kA at 230 V AC 50/60 Hz (EN/IEC 60898-1)
- Ultimate breaking capacity [Icu]: 70 kA at 12-60 V AC; 25 kA at 220-240 V AC; 25 kA at 12-48 V DC; 15 kA at 72 V DC (EN/IEC 60947-2)
- Service breaking capacity [Ics]: 12.5 kA (50%) at 220-240 V AC; 7500 A (50%) at 230 V AC per EN 60898-1
- Limiting class: 3 (EN/IEC 60898-1)
- Rated insulation voltage [Ui]: 500 V AC 50/60 Hz
- Rated impulse withstand voltage [Uimp]: 6 kV
- Overcurrent protection limit: 8 x In +/- 20%
- Use category: Category A (EN/IEC 60947-2)
- Mounting: Fixed, DIN rail
- Busbar comb distribution block: Upper or lower
- Width: 18 mm
- Height: 85 mm
- Depth: 78.5 mm
- Weight: 0.215 kg
- Connection: Single terminal block (upper or lower), 1-25 mm² rigid / 1-16 mm² flexible
- Tightening torque: 2 N.m
- Strip length: 14 mm
- IP rating: IP20 (IEC/EN 60529)
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 85 °C
- Relative humidity: 95% at 55 °C
- Mechanical durability: 20,000 cycles
- Electrical durability: 10,000 cycles
- Standards: IEC 60898-1, EN 60898-1, EN 60947-2, IEC 60947-2
- Colour: White
Features and benefits:
- High breaking capacity of 15 kA at 230 V AC for reliable overcurrent and short-circuit protection
- Suitable for both AC and DC networks, providing installation flexibility
- Contact position indicator and trip indicator for clear local status signalling
- Suitable for isolation per EN/IEC 60898-1 and EN/IEC 60947-2
- Compact 18 mm width allows space-efficient panel design on DIN rail
- Tropicalised to level 2 (IEC 60068-1) for reliable operation in high-humidity environments
Applications:
- Final distribution boards in residential and commercial electrical installations
- Industrial control panels requiring high breaking capacity at low AC or DC voltages
- Protection of circuits in switchboards and distribution enclosures
- DC applications including PV systems and battery-backed installations at 12-72 V DC
Compliant with IEC 60898-1, EN 60898-1, EN 60947-2, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F94110, Schneider Electric A9F94110, Acti9 iC60L 1P C10A MCB, Schneider 10A C-curve miniature circuit breaker.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact