Schneider A9F83106 Miniature Circuit Breaker (MCB), Acti9 iC60H, 1P 6A B curve 1
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F83106 is a 1-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 6 A with a B tripping curve. It delivers a breaking capacity of 10,000 A (Icn) at 230 V AC per EN/IEC 60898-1, and up to 15 kA (Icu) at 220-240 V AC per EN/IEC 60947-2, making it suitable for both residential and industrial distribution applications.
Technical specifications:
- Commercial reference: A9F83106
- Manufacturer: Schneider Electric
- Series / range: Acti 9 iC60
- Device short name: iC60H
- Number of poles: 1P
- Number of protected poles: 1
- Rated current (In): 6 A
- Tripping curve: B
- Network type: AC / DC
- Trip unit technology: Thermomagnetic
- Breaking capacity (Icn): 10,000 A at 230 V AC 50/60 Hz per EN/IEC 60898-1
- Breaking capacity (Icu): 15 kA at 220-240 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity (Icu): 42 kA at 12-60 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity (Icu): 15 kA at 100-133 V AC 50/60 Hz per EN/IEC 60947-2
- Breaking capacity (Icu): 15 kA at 72 V DC per EN/IEC 60947-2
- Breaking capacity (Icu): 20 kA at 12-60 V DC per EN/IEC 60947-2
- Rated insulation voltage (Ui): 500 V AC 50/60 Hz
- Rated impulse withstand voltage (Uimp): 6 kV
- Overcurrent protection limit: 4 x In +/- 20%
- Limitation class: 3 per EN/IEC 60898-1
- Use category: Category A per EN/IEC 60947-2
- Width: 18 mm
- Height: 85 mm
- Depth: 78.5 mm
- Weight: 0.215 kg
- IP rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 85 °C
- Relative humidity: 95% at 55 °C
- Mounting: DIN rail
- Connection: Single terminal block (top or bottom), 1-25 mm² rigid / 1-16 mm² flexible
- Tightening torque: 2 N.m (top or bottom)
- Strip length: 14 mm
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Pollution degree: 3
- Overvoltage category: IV
- Standards: EN/IEC 60898-1, EN/IEC 60947-2
Features and benefits:
- High breaking capacity of 10,000 A (Icn) at 230 V AC, providing robust short-circuit protection in demanding installations.
- B tripping curve suited for loads with low inrush current, minimising nuisance tripping on resistive and cable protection circuits.
- Compatible with both AC and DC networks, offering installation flexibility across diverse system types.
- Comb busbar connection supported from top or bottom, simplifying wiring in multi-pole distribution boards.
- Contact position indicator and trip indicator for fast visual diagnostics without opening the panel.
- Suitable for isolation duty per EN/IEC 60898-1 and EN/IEC 60947-2, enabling safe maintenance procedures.
Applications:
- Final distribution boards in residential and commercial buildings requiring reliable overcurrent and short-circuit protection.
- Industrial control panels where AC and DC network compatibility and high breaking capacity are essential.
- Cable protection in low-voltage switchgear and controlgear assemblies operating at 230 V AC or below.
- DIN rail enclosures in light industrial and building automation installations with limited panel width (18 mm pitch).
Compliant with EN/IEC 60898-1 and EN/IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F83106, Schneider Electric A9F83106, Acti9 iC60H 1P 6A MCB, Schneider 6A B-curve circuit breaker.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.