Circutor TP6 250/5 (code M78015) is a single-phase split core current transformer with a 250/5 A transformation ratio and a 30 × 30 mm conductor aperture. Its split core construction allows the unit to be clipped onto existing live cables or busbars without interrupting the circuit or dismantling the installation. The 5 A secondary output feeds compatible metering equipment, protection relays, or energy analysers.
Technical specifications:
- Model: TP6 250/5
- Circutor code: M78015
- EAN: 8433059401344
- Transformer type: Split core
- System: Single-phase
- Transformation ratio: 250/5 A
- Flat strip / inner aperture: 30 × 30 mm
- Class 1 rated burden: 1 VA
- Class 3 rated burden: 2 VA
- Safety factor (SF): 10
- Operating voltage: 0.72 kV~ max.
- Insulation voltage (S1-S2): 3 kV
- Nominal frequency: 50/60 Hz
- Thermal short-circuit current (Ith): 60 In
- Dynamic current (Idyn): 2.5 Ith
- Protection class: IP 20
- Enclosure: V0 self-extinguishing plastic
- Thermal class: B (+130 °C)
- Working temperature: -5 to +40 °C
- Storage temperature: -40 to +85 °C
- Relative humidity: 15 - 85% (without condensation)
- Dimensions (W × H × D): 100 × 51 × 101.8 mm
- Weight: 0.55 kg
- Mounting: Wall or DIN rail (accessory required)
- Maximum installation altitude: 1000 m
- Standards: UNE-EN 61869-1, UNE-EN 61869-2, UL 94
Features and benefits:
- Split core design allows fitting over live cables or busbars - no power shutdown or circuit dismantling needed
- V0 self-extinguishing plastic housing meets flame-retardant requirements for panel and switchgear environments
- Sealable terminals and cable fastening accessories are included as standard
- Dual accuracy rating (1 VA at Class 1 and 2 VA at Class 3) covers a range of metering and monitoring instrument requirements
- Supports wall or DIN rail mounting via accessory, providing flexibility when fitting inside distribution boards
Applications:
- Retrofitting current measurement onto live single-phase busbars up to 30 × 30 mm without a planned outage
- Sub-metering and energy measurement in single-phase distribution panels and switchboards
- Supplying a 5 A secondary signal to energy analysers, power monitors, or protection relays
- Cable and busbar installations in commercial or industrial premises where circuit interruption is not permitted
Also known as: Circutor TP6 250/5, TP6 250/5 M78015, Circutor M78015, split core current transformer 250A, Circutor split core CT 250/5.