Circutor M78012 TP6 Split Core Current Transformer 100/5A, 30x30mm
Free Shipping
Get free shipping on orders exceeding €300!
The Circutor TP6 100/5 (code M78012) is a single-phase split-core current transformer rated 100/5 A with a 30 × 30 mm busbar and cable opening. The split-core construction allows the unit to be fitted around an energised conductor or busbar without interrupting the circuit, making it well suited to retrofit metering work. The secondary output is a standard 5 A signal compatible with energy meters and panel instruments.
Technical specifications:
- Model: TP6 100/5
- Circutor code: M78012
- EAN: 8433059401184
- Measurement range: 100/5 A
- System: Single-phase
- Transformer type: Split core
- Busbar / flat strip opening: 30 × 30 mm
- Inner diameter: 30 mm
- Rated power (Class 3): 1 VA
- Safety factor (SF): 10
- Insulation voltage between terminals S1-S2: 3 kV
- Operating voltage: 0.72 kV~ max.
- Nominal frequency: 50/60 Hz
- Dynamic current (Idyn): 2.5 Ith
- Thermal short-circuit current (Ith): 60 In
- Overall dimensions (W × H × D): 100 × 51 × 101.8 mm
- Enclosure: Plastic, V0 self-extinguishing
- Mounting: Wall-mounted or DIN rail (accessory required)
- Weight: 0.55 kg
- Protection class: IP 20
- Thermal class: Class B (max. +130 °C)
- Working temperature: -5 to +40 °C
- Storage temperature: -40 to +85 °C
- Relative humidity: 15-85% (non-condensing)
- Maximum installation altitude: 1000 m
- Standards: UNE-EN 61869-1, UNE-EN 61869-2, UL 94
Features and benefits:
- Split-core design permits installation on live cables and busbars, removing the need for a planned power interruption.
- Accepts flat conductors and busbars up to 30 × 30 mm without dismantling existing wiring or switchgear.
- V0 self-extinguishing plastic enclosure limits fire propagation inside closed panels and distribution boards.
- Sealable terminals and cable fastening accessories are supplied with the unit, covering standard installation requirements without additional procurement.
- Rated for working temperatures from -5 to +40 °C and storage down to -40 °C, suitable for indoor panels and unheated enclosures.
Applications:
- Retrofitting energy monitoring or billing metering to live low-voltage distribution boards where a power outage is impractical.
- Current measurement in single-phase cable or busbar systems with conductors up to 30 × 30 mm.
- Supplying a 5 A secondary signal to panel instruments, energy analysers, or power meters.
- Metering installations requiring sealable, tamper-evident measurement terminals.
Also known as: Circutor TP6 100/5, TP6 100/5 M78012, Circutor M78012, split core current transformer 100/5 A, split core CT 30 × 30 mm.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.