{"product_id":"eaton-112927-pf6-63-2-003-a-residual-current-circuit-breaker-rccb-2p-63a-30ma-type-a","title":"Eaton 112927 PF6-63\/2\/003-A RCCB 2P 63 A 30mA Type A DIN Rail","description":"\u003cp\u003eThe Eaton PF6-63\/2\/003-A is a 2-pole Type A residual current circuit breaker (RCCB) from the Moeller series xPole range, rated at 63 A with a 30 mA trip threshold and 6 kA short-time withstand current. Pulse-current sensitive and partially surge-proof up to 250 A, it is designed for residual current protection in residential and commercial distribution boards.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-63\/2\/003-A\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 112927\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015081124657\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 63 A\u003c\/li\u003e\n  \u003cli\u003eFault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: Type A, pulse-current sensitive\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: Partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 35 mm (2 SU)\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25-55 °C \/ 90-95% RH per IEC 60068-2\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid-core): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (multi-wired): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminals: Open mouthed\/lift terminals, finger and touch safe (DGUV VS3, EN 50274)\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: max 40 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 - 250 V AC\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 9.7 W\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eCertification: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A sensitivity detects both sinusoidal and pulsating DC residual currents for broad protection coverage\u003c\/li\u003e\n  \u003cli\u003ePartial surge protection up to 250 A reduces nuisance tripping caused by transient overvoltages\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail attachment with 2 latch positions enables fast, tool-free installation per IEC\/EN 60715\u003c\/li\u003e\n  \u003cli\u003eFinger and touch-safe open mouthed\/lift terminals comply with DGUV VS3 and EN 50274 for safe wiring\u003c\/li\u003e\n  \u003cli\u003eWide ambient operating range (-25 °C to 60 °C) with automatic current derating of 1.8% per 1 °C above 40 °C\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-FW\/LP remote control device, KLV-TC-2 compact enclosure, and Z-RC\/AK-2TE sealing cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidual current protection in domestic and residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical installations requiring Type A RCCB protection\u003c\/li\u003e\n  \u003cli\u003eFinal circuits supplying loads with pulsating DC leakage currents such as frequency inverters and EV chargers\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring partial surge immunity to prevent unwanted tripping\u003c\/li\u003e\n  \u003cli\u003exPole DIN rail assemblies housed in KLV-TC-2 compact enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of Eaton's Moeller series xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-63\/2\/003-A, Eaton 112927, Eaton catalog 112927, Eaton model PF6-63\/2\/003-A, Eaton xPole RCCB 63 A 30 mA Type A, Eaton Moeller PF6 RCCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":57817912312072,"sku":"ETN112927","price":65.33,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/eaton-112927-pf6-632003-a-residual-current-circuit-breaker-rccb-2p-63a-30ma-type-a-6049892.jpg?v=1779034725","url":"https:\/\/gabbyelectric.com\/en-ca\/products\/eaton-112927-pf6-63-2-003-a-residual-current-circuit-breaker-rccb-2p-63a-30ma-type-a","provider":"Gabby Electric","version":"1.0","type":"link"}