Schneider A9F73306 Acti9 iC60N MCB 3P 6 A B Curve 10kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F73306 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 iC60N range, rated at 6 A with a B tripping curve. Designed for electrical power distribution, it provides thermomagnetic overcurrent protection with a breaking capacity of 10 kA at 380-415 V AC, making it suitable for both AC and DC networks.
Technical specifications:
- Commercial reference: A9F73306
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Product type: Miniature Circuit Breaker (MCB)
- Short designation: iC60N
- Number of poles: 3P
- Number of protected poles: 3
- Rated current: 6 A
- Tripping curve: B
- Network type: AC / DC
- Protection unit technology: Thermomagnetic
- Breaking capacity (Icn): 6000 A at 400 V AC per EN/IEC 60898-1
- Breaking capacity (Icu): 10 kA at 380-415 V AC per EN/IEC 60947-2
- Breaking capacity (Icu): 20 kA at 220-240 V AC per EN/IEC 60947-2
- Breaking capacity (Icu): 10 kA at up to 180 V DC per EN/IEC 60947-2
- Limitation class: 3 per EN/IEC 60898-1
- Rated insulation voltage (Ui): 500 V AC
- Rated impulse withstand voltage (Uimp): 6 kV
- Mounting: DIN rail
- Width: 54 mm
- Height: 85 mm
- Depth: 78.5 mm
- Weight: 0.375 kg
- IP protection rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 85 °C
- Relative humidity: 95% at 55 °C
- Connection: Single terminal block (top or bottom), 1-25 mm² rigid / 1-16 mm² flexible
- Tightening torque: 2 N.m
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Standards: IEC 60947-2, IEC 60898-1, EN 60947-2, EN 60898-1
Features and benefits:
- Thermomagnetic protection technology ensures reliable overcurrent and short-circuit protection
- B tripping curve optimised for circuits with low inrush current loads such as resistive and lighting applications
- Compatible with comb busbar distribution blocks (top or bottom), simplifying panel wiring
- Contact position indicator and trip indicator enable quick visual status verification
- Wide operating temperature range (-35 to 70 °C) and tropicalisation class 2 for demanding environments
- Suitable for isolation duty per EN/IEC 60898-1 and EN/IEC 60947-2
Applications:
- Final distribution boards in residential and commercial buildings
- Protection of lighting circuits and resistive loads in electrical panels
- Industrial control panels requiring AC or DC circuit protection
- Low-voltage power distribution switchboards
Compliant with IEC 60947-2, IEC 60898-1, EN 60947-2, and EN 60898-1. Part of the Schneider Electric Acti 9 iC60 range.