Schneider A9F84240 Miniature Circuit Breaker (MCB), Acti9 iC60H 2P C40A 10kA
Free Shipping
Get free shipping on orders exceeding €300!
The Schneider Electric A9F84240 is a 2-pole miniature circuit breaker (MCB) from the Acti 9 iC60H range, rated at 40 A with a C tripping curve. It provides thermomagnetic overcurrent protection for AC and DC distribution networks, with a breaking capacity of 10 kA Icn at 400 V AC per EN/IEC 60898-1.
Technical specifications:
- Commercial reference: A9F84240
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 iC60
- Device short name: iC60H
- Number of poles: 2P
- Number of protected poles: 2
- Rated current [In]: 40 A
- Tripping curve: C
- Network type: AC / DC
- Protection unit technology: Thermomagnetic
- Breaking capacity [Icn]: 10 kA at 400 V AC 50/60 Hz per EN/IEC 60898-1
- Ultimate breaking capacity [Icu]: 30 kA at 220-240 V AC / 15 kA at 380-415 V AC / 10 kA at 440 V AC / 15 kA at ≤125 V DC per EN/IEC 60947-2
- Service breaking capacity [Ics]: 15 kA at 220-240 V AC / 7.5 kA at 380-415 V AC / 5 kA at 440 V AC per EN/IEC 60947-2
- Limitation class: 3 per EN/IEC 60898-1
- Rated insulation voltage [Ui]: 500 V AC 50/60 Hz per EN/IEC 60947-2
- Rated impulse withstand voltage [Uimp]: 6 kV per EN/IEC 60947-2
- Overcurrent protection limit: 8 x In +/- 20%
- Mounting: DIN rail
- Width: 36 mm
- Height: 85 mm
- Depth: 78.5 mm
- Weight: 0.25 kg
- Connection: Single terminal block (top or bottom), 1-35 mm² rigid / 1-25 mm² flexible
- Tightening torque: 3.5 N.m
- IP protection rating: IP20 per IEC/EN 60529
- Operating temperature: -35 to 70 °C
- Storage temperature: -40 to 85 °C
- Relative humidity: 95% at 55 °C
- Pollution degree: 3 per EN/IEC 60947-2
- Overvoltage category: IV
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Colour: White
- Standards: EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2
Features and benefits:
- Thermomagnetic protection technology provides reliable overload and short-circuit protection in a compact 2-module width
- High breaking capacity of 10 kA Icn at 400 V AC makes it suitable for demanding industrial and commercial distribution applications
- Compatible with both AC and DC networks, offering application flexibility
- Comb busbar distribution block compatible (top or bottom), simplifying panel wiring
- Trip indicator for quick visual fault identification, with contact position indicator
- Suitable for isolation per EN/IEC 60898-1 and EN/IEC 60947-2
Applications:
- Final distribution boards in commercial and industrial buildings
- Protection of outgoing circuits in low-voltage switchboards and panel boards
- Motor and equipment protection in industrial automation panels
- DC circuit protection in photovoltaic and battery systems
- Sub-distribution in infrastructure and tertiary sector installations
Compliant with EN 60898-1, EN 60947-2, IEC 60898-1, and IEC 60947-2. Part of the Schneider Electric Acti 9 iC60 range.
Also known as: Schneider A9F84240, Schneider Electric A9F84240, Acti9 iC60H 2P C40A MCB, Schneider 40A 2-pole circuit breaker.
When sold out, you can still preorder by requesting a quote below.
Important
The images shown are for illustration purposes only and may not be an exact
representation of the product.