Schneider Electric 18637 is a 3-pole miniature circuit breaker (MCB) from the Acti 9 NG125N range, rated at 40 A with a C tripping curve and a breaking capacity of 25 kA at 380-415 V AC per IEC 60947-2. Designed for electrical power distribution, it supports both AC and DC networks with thermomagnetic protection technology.
Technical specifications:
- Commercial reference: 18637
- Manufacturer: Schneider Electric
- EAN:
- Series / range: Acti 9 NG125
- Product type: Miniature circuit breaker (MCB)
- Short device name: NG125N
- Number of poles: 3P
- Number of protected poles: 3
- Rated current [In]: 40 A at 40°C
- Tripping curve: C
- Network type: AC / DC
- Protection technology: Thermomagnetic
- Breaking capacity [Icu]: 50 kA at 220-240 V AC; 25 kA at 380-415 V AC; 20 kA at 440 V AC; 10 kA at 500 V AC; 20 kA at up to 375 V DC (EN/IEC 60947-2)
- Service breaking capacity [Ics]: 37.5 kA (220-240 V AC); 18.75 kA (380-415 V AC); 15 kA (440 V AC); 7.5 kA (500 V AC)
- Rated voltage [Ue]: 220-240 V / 380-415 V / 440 V / 500 V AC 50/60 Hz; up to 375 V DC
- Rated insulation voltage [Ui]: 690 V AC
- Rated impulse withstand voltage [Uimp]: 8 kV
- Overcurrent protection limit: 8 x In
- Use category: Category A per IEC 60947-2
- Standard: EN/IEC 60947-2
- IP protection: IP20 (IEC 60529)
- IK protection: IK05 (EN/IEC 62262)
- Operating temperature: -30 to 70°C
- Storage temperature: -40 to 70°C
- Relative humidity: 95% at 55°C
- Mounting: 35 mm symmetrical DIN rail, click-on
- Handle position: Vertical
- Connection terminals: Tunnel terminals 1.5-50 mm² (rigid); 1-35 mm² (flexible)
- Tightening torque: 3.5 N.m
- Strip length: 20 mm
- Dimensions (WxHxD): 81 x 103 x 81 mm
- Weight: 0.72 kg
- Mechanical endurance: 20,000 cycles
- Electrical endurance: 10,000 cycles
- Busbar comb rail compatible: Yes (9 mm pitch)
Features and benefits:
- High breaking capacity of 25 kA at 380-415 V AC suitable for demanding industrial and commercial installations
- Dual AC/DC network compatibility provides flexibility across a wide range of electrical systems
- Integrated locking preparation allows the handle to be padlocked in the OFF position for safe isolation
- Contact position indicator and trip indicator enable quick visual status checks
- Click-on DIN rail mounting and comb busbar compatibility simplify panel assembly
- Wide operating temperature range (-30 to 70°C) suits both indoor and harsh-environment enclosures
Applications:
- Final and sub-distribution boards in commercial and industrial buildings
- Protection of outgoing circuits in main distribution panels
- DC circuit protection in photovoltaic and battery storage installations
- Motor and equipment protection in industrial automation panels
- High-fault-level environments requiring elevated breaking capacity
Compliant with EN/IEC 60947-2. Part of the Schneider Electric Acti 9 NG125 range.