{"title":"Residual Current Circuit Breakers RCCB","description":"\u003cp\u003eResidual Current Circuit Breakers (RCCBs) provide essential protection against electric shock and earth leakage in electrical installations. They instantly disconnect the circuit when a fault is detected, preventing damage to equipment and ensuring personal safety. Ideal for residential, commercial, and industrial systems, RCCBs improve overall electrical reliability and compliance with modern safety standards.\u003cbr data-start=\"490\" data-end=\"493\"\u003eGabby Electric offers a wide selection of RCCBs from leading manufacturers such as ABB, Siemens, Schneider Electric, Hager, Legrand, Eaton, and Schelinger - available in multiple ratings and configurations with fast EU-wide delivery.\u003c\/p\u003e","products":[{"product_id":"a9r21225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-a-type-30ma","title":"Schneider A9R21225 Acti9 iID RCCB 2P 25 A 30mA Type A","description":"\u003cp\u003eThe Schneider Electric A9R21225 is a 2-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 iID range, rated at 25 A with a 30 mA trip sensitivity. Designed for Type A networks, it provides instantaneous residual current protection and is suitable for final distribution in residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9R21225\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eTripping delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eResidual current protection class: Type A\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220...240 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated making and breaking capacity: Idm 1500 A \/ Im 1500 A\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eSurge current: 250 A\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, clip-on system\u003c\/li\u003e\n  \u003cli\u003eDIN row width: 4 x 9 mm modules\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 91 x 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.21 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529), IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block top or bottom, 1...35 mm² rigid \/ 1...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 61008-1\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance (AC-1): 15,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A residual current protection detects both sinusoidal and pulsating DC residual currents\u003c\/li\u003e\n  \u003cli\u003eInstantaneous tripping for fast disconnection upon residual current fault\u003c\/li\u003e\n  \u003cli\u003eIndependent tripping technology ensures operation regardless of supply voltage\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides visual confirmation of switch state\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting for quick and tool-free installation\u003c\/li\u003e\n  \u003cli\u003eLocking device option available for tamper-resistant applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential buildings for personal protection against electric shock\u003c\/li\u003e\n  \u003cli\u003eCommercial installations requiring Type A residual current protection for electronic equipment circuits\u003c\/li\u003e\n  \u003cli\u003eDownstream protection in modular enclosures within light industrial panels\u003c\/li\u003e\n  \u003cli\u003eProtection of socket outlet circuits and lighting circuits in compliance with EN\/IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9R21225, Schneider Electric A9R21225, Schneider RCCB 2P 25A 30mA, Schneider residual current device Type A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333018888,"sku":"SCHA9R21225","price":32.68,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r21225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-a-type-30ma-517757.jpg?v=1735231322"},{"product_id":"a9r21440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-a-type-30ma","title":"Schneider A9R21440 Acti9 iID RCCB 4P 40 A 30mA Type A","description":"\u003cp\u003eThe Schneider Electric A9R21440 is a 4-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 iID series, rated at 40 A with 30 mA Type A residual current sensitivity. It operates on AC networks at 380 to 415 V with instantaneous tripping and a 10 kA rated conditional short-circuit current.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9R21440\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNeutral conductor position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC, 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 380 to 415 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRCD sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eRCD class: Type A\u003c\/li\u003e\n  \u003cli\u003eTrip delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eTripping technology: Independent\u003c\/li\u003e\n  \u003cli\u003eRated making\/breaking capacity: Idm\/Im 1500 A\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, clip-on system, 8 x 9 mm modules\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 72 x 91 x 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.37 kg\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block top or bottom, 1 to 35 mm² rigid, 1 to 25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m, strip length 14 mm\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 \/ IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 60 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eInstantaneous trip delay provides rapid disconnection on residual current fault detection\u003c\/li\u003e\n  \u003cli\u003eIndependent tripping technology ensures reliable operation\u003c\/li\u003e\n  \u003cli\u003eContact position indicator gives clear visual confirmation of switch state\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting allows fast installation in modular enclosures\u003c\/li\u003e\n  \u003cli\u003eRated for 20,000 mechanical operating cycles for extended service life\u003c\/li\u003e\n  \u003cli\u003eLocking device option available to restrict unauthorized switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eOutgoing circuit protection in modular distribution enclosures\u003c\/li\u003e\n  \u003cli\u003e4-pole residual current protection on three-phase AC networks\u003c\/li\u003e\n  \u003cli\u003eIndustrial distribution panels requiring Type A RCD protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9R21440, Schneider Electric A9R21440, Acti9 iID 4P 40A 30mA RCCB, Schneider RCCB Type A 4-pole 40A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333149960,"sku":"SCHA9R21440","price":53.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r21440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-a-type-30ma-169712.jpg?v=1735231322"},{"product_id":"a9r41225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-ac-type-30ma","title":"Schneider A9R41225 Acti9 iID RCCB 2P 25 A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9R41225 is a 2-pole RCCB from the Acti 9 iID range, rated 25 A with 30 mA sensitivity for Type AC residual current protection. It provides instantaneous tripping and a rated conditional short-circuit current of 10 kA, designed for load-side use in 220-240 V AC distribution systems.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9R41225\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB (Residual Current Circuit Breaker), 2P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eResidual current class: Type AC\u003c\/li\u003e\n  \u003cli\u003eTrip response: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated making\/breaking capacity: Idm\/Im 1500 A\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eNeutral conductor position: Left\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, click-on system, 4 x 9 mm modules\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 91 x 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.21 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 \/ IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -5 to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1-35 mm² rigid \/ 1-25 mm² flexible, tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 61008-1, EN\/IEC 61008-2-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eInstantaneous Type AC residual current protection with independent trip mechanism\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting enables fast, tool-free panel assembly\u003c\/li\u003e\n  \u003cli\u003eIntegrated contact position indicator provides instant visual status confirmation\u003c\/li\u003e\n  \u003cli\u003eLocking device option prevents unauthorized switching or tampering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential final circuits requiring 30 mA earth leakage protection\u003c\/li\u003e\n  \u003cli\u003eLight commercial distribution boards with Type AC RCCB requirements\u003c\/li\u003e\n  \u003cli\u003eModular DIN rail panels at load-side positions in electrical enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9R41225, Schneider Electric A9R41225, Acti9 iID RCCB 25A 30mA, Schneider RCCB 2P 25A 30mA.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333248264,"sku":"SCHA9R41225","price":29.77,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41225-residual-current-circuit-breaker-rccb-acti9-iid-2p-25a-ac-type-30ma-469002.jpg?v=1735231385"},{"product_id":"a9r41240-residual-current-circuit-breaker-rccb-acti9-iid-2p-40a-ac-type-30ma","title":"Schneider A9R41240 Acti9 iID RCCB 2P 40 A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9R41240 is a 2-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 iID series, rated at 40 A with 30 mA AC-type residual current sensitivity. It delivers instantaneous tripping on 220-240 V AC networks, providing earth leakage protection for residential and commercial electrical installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9R41240\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNeutral conductor position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA, Type AC\u003c\/li\u003e\n  \u003cli\u003eTrip delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse current: 250 A\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on DIN rail, 4 x 9 mm pitch\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 36 x 91 x 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.21 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529), IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -5 to 60 °C\u003c\/li\u003e\n  \u003cli\u003eConnection terminals: 1-35 mm² rigid, 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 61008-1, EN\/IEC 61008-2-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eInstantaneous tripping on AC-type residual currents for fast earth fault protection\u003c\/li\u003e\n  \u003cli\u003eVoltage-independent trip mechanism operates without mains voltage\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides clear visual status of the device\u003c\/li\u003e\n  \u003cli\u003eLockable handle for tamper prevention and controlled access\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting for quick installation in modular enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOutgoing earth leakage protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eFinal circuit protection in single-phase 220-240 V AC installations\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panels requiring Type AC residual current protection\u003c\/li\u003e\n  \u003cli\u003eModular enclosure systems with IP40 protection requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9R41240, Schneider Electric A9R41240, Acti9 iID 2P 40A 30mA RCCB.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333313800,"sku":"SCHA9R41240","price":27.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41240-residual-current-circuit-breaker-rccb-acti9-iid-2p-40a-ac-type-30ma-375306.jpg?v=1735231385"},{"product_id":"a9r41425-residual-current-circuit-breaker-rccb-acti9-iid-4p-25a-ac-type-30ma","title":"Schneider A9R41425 Acti9 iID RCCB 4P 25 A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9R41425 is a 4-pole RCCB from the Acti 9 iID range, rated at 25 A with 30 mA residual current sensitivity for Type AC networks. It provides instantaneous residual current protection and a 10 kA rated conditional short-circuit current, designed for outgoing circuit protection in modular distribution boards.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9R41425\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P, neutral position left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 380...415 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA, Type AC, instantaneous tripping\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMaking\/breaking capacity: Idm\/Im 1500 A\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, clip-on, 8 x 9 mm modules wide\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 72 x 91 x 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.37 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20, IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -5...60°C\u003c\/li\u003e\n  \u003cli\u003eConnection: 1...35 mm² rigid, 1...25 mm² flexible, tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 61008-1, EN\/IEC 61008-2-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eInstantaneous residual current tripping with independent tripping technology, requiring no supply voltage to operate\u003c\/li\u003e\n  \u003cli\u003eVisual contact position indicator for immediate status verification without opening the enclosure\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting with locking device option for secure panel installation\u003c\/li\u003e\n  \u003cli\u003eMechanical durability of 20,000 cycles and electrical durability of 15,000 cycles (AC-1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOutgoing circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eThree-phase and neutral 380-415 V AC circuits requiring earth fault protection\u003c\/li\u003e\n  \u003cli\u003eModular enclosure assemblies requiring Type AC residual current protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial and commercial panels where sinusoidal residual current faults must be detected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9R41425, Schneider Electric A9R41425, Acti 9 iID RCCB 4P 25A 30mA.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333379336,"sku":"SCHA9R41425","price":41.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41425-residual-current-circuit-breaker-rccb-acti9-iid-4p-25a-ac-type-30ma-348688.jpg?v=1735231384"},{"product_id":"a9r41440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma","title":"Schneider A9R41440 Acti9 iID RCCB 4P 40 A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9R41440 is a 4-pole residual current circuit breaker (RCCB) from the Acti 9 iID range, rated at 40 A with 30 mA sensitivity for AC-type earth fault protection. Designed as an outgoing device in AC distribution systems, it delivers instantaneous tripping to protect people and installations from residual fault currents.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9R41440\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: Residual current circuit breaker (RCCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNeutral conductor position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eTripping delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eResidual current class: Type AC\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 380...415 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated making\/breaking capacity: Idm\/Im 1500 A\u003c\/li\u003e\n  \u003cli\u003eSurge current withstand: 250 A (8\/20 µs)\u003c\/li\u003e\n  \u003cli\u003eMounting: Snap-on, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 91 x 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.37 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 \/ IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -5...60 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block upper or lower, 1...35 mm² rigid \/ 1...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 61008-1, EN\/IEC 61008-2-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eInstantaneous, voltage-independent tripping technology ensures reliable earth fault protection\u003c\/li\u003e\n  \u003cli\u003eSnap-on DIN rail mounting allows fast, tool-free installation\u003c\/li\u003e\n  \u003cli\u003eBuilt-in contact position indicator provides quick visual status check\u003c\/li\u003e\n  \u003cli\u003eCompatible locking device option prevents unauthorized switching\u003c\/li\u003e\n  \u003cli\u003eWide conductor acceptance range (1...35 mm² rigid) suits diverse wiring configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eThree-phase and neutral AC circuit protection in modular enclosures\u003c\/li\u003e\n  \u003cli\u003eOutgoing feeder protection in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring Type AC residual current protection per IEC 61008\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 iID range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9R41440, Schneider Electric A9R41440, Schneider RCCB 4P 40A 30mA, Acti9 iID 4-pole RCD.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065333412104,"sku":"SCHA9R41440","price":40.04,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r41440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma-862931.jpg?v=1735231384"},{"product_id":"a9z05225-residual-current-circuit-breaker-rccb-acti9-id-k-2p-25a-ac-type-30ma","title":"Schneider A9Z05225 Acti9 ID K RCCB 2P 25 A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9Z05225 is a 2-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 ID K range, rated at 25 A with a 30 mA sensitivity for AC-type earth fault protection. Designed for final distribution, it provides instantaneous tripping to protect personnel and equipment against residual currents in AC networks operating at 220-240 V AC 50 Hz.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9Z05225\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 ID K\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eTripping delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eRCD class: Type AC\u003c\/li\u003e\n  \u003cli\u003eRated voltage (Ue): 220-240 V AC 50 Hz\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated making and breaking capacity: Idm 500 A, Im 500 A\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: GL63: Inc 4.5 kA \/ K60: Inc 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 440 V AC 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, click-on system, 9 mm pitch - 4 rows\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 81 x 68 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.18 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529) \/ IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -5 to 40 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -30 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Double connection upper or lower, 1-35 mm² rigid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 5000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: AC-1: 2000 cycles\u003c\/li\u003e\n  \u003cli\u003eQuality mark: VDE\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 61008-1, EN\/IEC 61008-2-1\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eInstantaneous tripping at 30 mA sensitivity for fast earth fault disconnection\u003c\/li\u003e\n  \u003cli\u003eType AC residual current detection covers sinusoidal fault currents\u003c\/li\u003e\n  \u003cli\u003eIndependent tripping technology ensures operation independent of mains voltage\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting for fast, tool-free installation in modular enclosures\u003c\/li\u003e\n  \u003cli\u003eDouble-terminal connection accepts both rigid and flexible conductors up to 35 mm²\u003c\/li\u003e\n  \u003cli\u003eVDE-certified and compliant with EN\/IEC 61008-1 for verified performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential final distribution boards requiring personal protection against earth faults\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panels with AC supply networks\u003c\/li\u003e\n  \u003cli\u003eModular DIN rail enclosures in offices, retail, and light industrial installations\u003c\/li\u003e\n  \u003cli\u003eOutgoing circuits requiring 30 mA RCD protection per electrical installation standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9Z05225, Schneider Electric A9Z05225, Schneider RCCB 2P 25A 30mA, Acti9 ID K residual current device.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065336492296,"sku":"SCHA9Z05225","price":17.44,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9z05225-residual-current-circuit-breaker-rccb-acti9-id-k-2p-25a-ac-type-30ma-668883.jpg?v=1735231609"},{"product_id":"a9z05240-residual-current-circuit-breaker-rccb-acti9-id-k-2p-40a-ac-type-30ma","title":"Schneider A9Z05240 Acti9 ID K RCCB 2P 40 A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9Z05240 is an Acti 9 ID K Residual Current Circuit Breaker (RCCB), a 2-pole 40 A device with 30 mA sensitivity for Type AC residual current protection. Designed for instant tripping, it provides reliable protection against earth leakage currents in AC networks at 220-240 V.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9Z05240\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 ID K\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eNeutral conductor position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eTripping delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eResidual current class: Type AC\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220-240 V AC 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eMaking and breaking rated capacity: Idm 500 A, Im 500 A\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: GL63: Inc 4.5 kA \/ K60: Inc 6 kA\u003c\/li\u003e\n  \u003cli\u003eMounting: Click-on system, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDIN rail rows: 4 (9 mm pitch)\u003c\/li\u003e\n  \u003cli\u003eDimensions (HxWxD): 81 x 36 x 68 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.18 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529), IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -5 to 40 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -30 to 70 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Dual connection upper or lower, 1-35 mm² solid \/ 1-25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 61008-1, EN\/IEC 61008-2-1\u003c\/li\u003e\n  \u003cli\u003eQuality marks: VDE\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 5000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance (AC-1): 2000 cycles\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC residual current protection detects sinusoidal alternating fault currents for standard residential and commercial AC circuits.\u003c\/li\u003e\n  \u003cli\u003eInstantaneous tripping at 30 mA sensitivity ensures fast disconnection to protect against electric shock hazards.\u003c\/li\u003e\n  \u003cli\u003eIndependent residual current tripping technology operates without requiring an auxiliary supply.\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting allows quick and tool-free installation in modular distribution boards.\u003c\/li\u003e\n  \u003cli\u003eDual upper or lower connection terminals accept both solid and flexible conductors up to 35 mm².\u003c\/li\u003e\n  \u003cli\u003eVDE certified and fully compliant with EN\/IEC 61008-1 for assured quality and interoperability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential distribution boards requiring earth leakage protection on final circuits.\u003c\/li\u003e\n  \u003cli\u003eCommercial installations where Type AC residual current protection is required on 40 A circuits.\u003c\/li\u003e\n  \u003cli\u003eModular enclosure systems where IP40 ingress protection is needed at the device level.\u003c\/li\u003e\n  \u003cli\u003eOutgoing circuit protection in consumer units operating on 220-240 V AC 50\/60 Hz networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9Z05240, Schneider Electric A9Z05240, Acti9 IDK 2P 40A 30mA RCCB, Schneider residual current circuit breaker 40A Type AC.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065336557832,"sku":"SCHA9Z05240","price":20.44,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9z05240-residual-current-circuit-breaker-rccb-acti9-id-k-2p-40a-ac-type-30ma-720064.jpg?v=1735231609"},{"product_id":"a9z05425-residual-current-circuit-breaker-rccb-acti9-id-k-4p-25a-ac-type-30ma","title":"Schneider A9Z05425 Acti9 ID K RCCB 4P 25 A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9Z05425 is a 4-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 ID K range, rated at 25 A with 30 mA sensitivity. Designed for Type AC networks, it provides reliable earth fault protection with instantaneous tripping action and is suitable for use as an outgoing device in distribution systems.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9Z05425\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 ID K\u003c\/li\u003e\n  \u003cli\u003eProduct type: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eTripping delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eResidual current class: Type AC\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 380...415 V AC 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eRated making and breaking capacity: Idm 500 A \/ Im 500 A\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: GL63: Inc 4.5 kA \/ K60: Inc 6 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse current: 250 A\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Click-on system, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDIN rail rows: 9 mm, 8 modules wide\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 81 x 68 mm\u003c\/li\u003e\n  \u003cli\u003eConnection: Double connection upper or lower, 1...35 mm² rigid \/ 1...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eStrip length: 14 mm\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC 60529) \/ IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -5...40 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -30...70 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical durability: 5000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical durability (AC-1): 2000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 61008-1, EN\/IEC 61008-2-1\u003c\/li\u003e\n  \u003cli\u003eQuality marks: VDE\u003c\/li\u003e\n  \u003cli\u003eColor: White\u003c\/li\u003e\n  \u003cli\u003eWeight: 349 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eInstantaneous tripping action provides fast protection against residual earth fault currents.\u003c\/li\u003e\n  \u003cli\u003eType AC residual current class detects sinusoidal alternating residual currents.\u003c\/li\u003e\n  \u003cli\u003eClick-on DIN rail mounting simplifies installation in modular enclosures.\u003c\/li\u003e\n  \u003cli\u003eDouble connection terminals (upper or lower) accept both rigid and flexible conductors up to 35 mm².\u003c\/li\u003e\n  \u003cli\u003eIP40 protection rating when installed in a modular enclosure, suitable for a range of environments.\u003c\/li\u003e\n  \u003cli\u003eVDE certified, meeting EN\/IEC 61008-1 and EN\/IEC 61008-2-1 for assured compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOutgoing protection in residential and commercial final distribution boards.\u003c\/li\u003e\n  \u003cli\u003eEarth fault protection for three-phase plus neutral circuits in AC systems.\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits in modular DIN rail enclosures in building installations.\u003c\/li\u003e\n  \u003cli\u003eSupplementary earth leakage protection in industrial and commercial electrical panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9Z05425, Schneider Electric A9Z05425, Acti9 ID K RCCB 4P 25A 30mA, Schneider 4-pole residual current device 25A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065336688904,"sku":"SCHA9Z05425","price":22.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9z05425-residual-current-circuit-breaker-rccb-acti9-id-k-4p-25a-ac-type-30ma-804557.jpg?v=1735231609"},{"product_id":"a9z05440-residual-current-circuit-breaker-rccb-acti9-id-k-4p-40a-ac-type-30ma","title":"Schneider A9Z05440 Acti9 ID K RCCB 4P 40 A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9Z05440 is a 4-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 ID K range, rated at 40 A with 30 mA sensitivity for AC-type earth leakage protection. Designed for downstream distribution, it provides instantaneous trip operation with independent tripping technology, offering reliable personnel and equipment protection in residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9Z05440\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 ID K\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNeutral conductor position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eTrip delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eResidual current class: Type AC\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 380...415 V AC 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 440 V AC 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eMaking and breaking capacity: Idm 500 A \/ Im 500 A\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: GL63: Inc 4.5 kA \/ K60: Inc 6 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse current: 250 A\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, DIN rail\u003c\/li\u003e\n  \u003cli\u003eDIN rail rows: 9 mm, 8 modules wide\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 81 x 68 mm\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529), IP40 in modular enclosure\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -5...40 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -30...70 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Dual connection top or bottom, 1...35 mm² rigid \/ 1...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 5000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance (AC-1): 2000 cycles\u003c\/li\u003e\n  \u003cli\u003eCertifications: OVE, VDE\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 61008-1, EN\/IEC 61008-2-1\u003c\/li\u003e\n  \u003cli\u003eWeight: 347 g\u003c\/li\u003e\n  \u003cli\u003eWarranty: 18 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eInstantaneous tripping with independent trip technology ensures fast fault clearance without reliance on supply voltage.\u003c\/li\u003e\n  \u003cli\u003eType AC sensitivity detects sinusoidal residual currents, suitable for standard residential and light commercial loads.\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting simplifies installation and replacement within Acti 9 modular enclosures.\u003c\/li\u003e\n  \u003cli\u003eDual top or bottom connection accepts both rigid and flexible conductors up to 35 mm², providing wiring flexibility.\u003c\/li\u003e\n  \u003cli\u003eOVE and VDE certified, meeting EN\/IEC 61008-1 requirements for use across European markets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential buildings requiring earth leakage protection on 3-phase + neutral circuits.\u003c\/li\u003e\n  \u003cli\u003eCommercial premises distribution panels where 4-pole 40 A earth fault protection is required.\u003c\/li\u003e\n  \u003cli\u003eIndustrial auxiliary circuits requiring AC-type differential protection at the outgoing feeder level.\u003c\/li\u003e\n  \u003cli\u003eModular switchboards built on the Acti 9 system platform in DIN rail enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9Z05440, Schneider Electric A9Z05440, Acti9 IDK 4P 40A 30mA RCCB, Schneider 4-pole residual current circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44065337213192,"sku":"SCHA9Z05440","price":27.51,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9z05440-residual-current-circuit-breaker-rccb-acti9-id-k-4p-40a-ac-type-30ma-871076.jpg?v=1735231609"},{"product_id":"a9a26919-auxiliary-contact-acti9-a9a-isd-of-2-c-o-2ma-to-100ma-24vac-to-250vac-24vdc-to-220vdc-top-and-bottom-connection","title":"Schneider A9A26919 Acti9 Auxiliary Contact iSD+OF 2 C\/O 24-250V AC\/DC","description":"\u003cp\u003eThe Schneider Electric A9A26919 is an auxiliary contact module for the Acti 9 range, combining an iSD fault current indicator and an OF position contact in a single 9 mm wide clip-on unit. It provides 2 changeover (2 C\/O) signal contacts rated for 2-100 mA at 24-240V AC and 24-220V DC, enabling remote status monitoring of the parent circuit breaker.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9A26919\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9\u003c\/li\u003e\n  \u003cli\u003eDevice type: Auxiliary contact - OC and fault contact (iSD+OF)\u003c\/li\u003e\n  \u003cli\u003eSignal contacts: 2 C\/O (2 changeover)\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 2-100 mA at 24-240V AC 50\/60 Hz; 2-100 mA at 24, 48, 60, 130, 220V DC\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 4 kV\u003c\/li\u003e\n  \u003cli\u003eOperating mode: Daisy chain up to 100 devices\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, left side of circuit breaker, DIN rail\u003c\/li\u003e\n  \u003cli\u003eLocal signaling: Mechanical indicator\u003c\/li\u003e\n  \u003cli\u003eWidth: 9 mm, Height: 90 mm, Depth: 73 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 40 g\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 3\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 to 70°C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to 85°C\u003c\/li\u003e\n  \u003cli\u003eRelative humidity: 95% at 55°C\u003c\/li\u003e\n  \u003cli\u003eConnection: Screw terminal (top and bottom), 1 cable 1-4 mm² rigid \/ 0.5-2.5 mm² flexible; 2 cables 2.5 mm² rigid \/ 1.5 mm² flexible with ferrule\u003c\/li\u003e\n  \u003cli\u003eStrip length: 10 mm, Tightening torque: 1 N.m\u003c\/li\u003e\n  \u003cli\u003eCertifications: CE, UKCA, EAC, CCC\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 60947-5-1, EN\/IEC 60947-5-4, GB\/T 14048.5, GB\/T 14048.17\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCombines fault current indication (iSD) and breaker position contact (OF) in one compact 9 mm module\u003c\/li\u003e\n  \u003cli\u003eDaisy-chain wiring supports up to 100 devices on a single signal loop, reducing installation complexity\u003c\/li\u003e\n  \u003cli\u003eWide voltage range (24-250V AC\/DC) makes it compatible with diverse PLC and BMS signal inputs\u003c\/li\u003e\n  \u003cli\u003eTool-free clip-on mounting to the left side of Acti 9 circuit breakers for fast panel assembly\u003c\/li\u003e\n  \u003cli\u003eMechanical indicator provides local visual status without requiring auxiliary power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRemote monitoring of Acti 9 circuit breaker trip and position status in building management systems\u003c\/li\u003e\n  \u003cli\u003eFault signaling in industrial distribution panels and motor control centers\u003c\/li\u003e\n  \u003cli\u003eIntegration with SCADA or PLC systems requiring low-level mA signal contacts\u003c\/li\u003e\n  \u003cli\u003eEnergy management and power monitoring installations requiring breaker state feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 60947-5-1 and EN\/IEC 60947-5-4. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9A26919, Schneider Electric A9A26919, Acti9 iSD+OF auxiliary contact, Acti 9 2 C\/O signal contact.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44074861494536,"sku":"SCHA9A26919","price":21.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9a26919-auxiliary-contact-acti9-a9a-isdof-2-co-2ma-to-100ma-24vac-to-250vac-24vdc-to-220vdc-top-and-bottom-connection-9366851.jpg?v=1757426567"},{"product_id":"a9r11440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma","title":"Schneider A9R11440 Acti9 iID RCCB 4P 40 A 30mA Type AC","description":"\u003cp\u003eThe Schneider Electric A9R11440 is a 4P residual current circuit breaker from the Acti9 iID range, rated 40 A with 30mA sensitivity, Type AC. It provides earth leakage protection for final circuits and sub-boards in domestic, commercial, and industrial distribution boards. Mounts on 35mm DIN rail in 18mm Acti9 module format.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePart number: A9R11440\u003c\/li\u003e\n\u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eSeries: Acti9 iID\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30mA\u003c\/li\u003e\n\u003cli\u003eType: AC\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400V AC 3-phase\u003c\/li\u003e\n\u003cli\u003eMounting: 35mm DIN rail, 18mm\/pole\u003c\/li\u003e\n\u003cli\u003eStandards: IEC\/EN 61008-1, CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eType AC - detects sinusoidal AC residual currents, suitable for standard domestic and commercial circuits\u003c\/li\u003e\n\u003cli\u003eActi9 iID system - compatible with Vigi add-on blocks and Acti9 comb busbars\u003c\/li\u003e\n\u003cli\u003e18mm\/pole module width - fits standard Acti9 distribution boards alongside MCBs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMain RCD protection for groups of circuits in domestic and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eSocket outlet and appliance circuit protection requiring earth leakage protection\u003c\/li\u003e\n\u003cli\u003eTT earthing system main earth leakage protection at board incomer\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Schneider A9R11440, Acti9 iID 4P 40 A 30mA Type AC RCCB, A9R11440 earth leakage circuit breaker.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075764154632,"sku":"SCHA9R11440","price":33.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r11440-residual-current-circuit-breaker-rccb-acti9-iid-4p-40a-ac-type-30ma-767861.jpg?v=1735231322"},{"product_id":"a9r21425-residual-current-circuit-breaker-rccb-acti9-iid-4p-25a-a-type-30ma","title":"Schneider A9R21425 Acti9 iID RCCB 4P 25 A 30mA Type A","description":"\u003cp\u003eThe Schneider Electric A9R21425 is a 4-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 iID range, designed to provide residual current protection with a 25 A rated current and 30 mA sensitivity. It operates on Type A networks, detecting both sinusoidal and pulsating DC residual currents, making it suitable for modern electrical installations with electronic equipment.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9R21425\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 25 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eTripping delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eResidual current class: Type A\u003c\/li\u003e\n  \u003cli\u003eRated make\/break capacity: Idm 1500 A, Im 1500 A\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 380...415 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eNetwork frequency: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, clip-on\u003c\/li\u003e\n  \u003cli\u003eDIN rail rows: 9 mm, 8 modules wide\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 91 x 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.37 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IEC 60529), IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal top or bottom, 1...35 mm² rigid \/ 1...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance (AC-1): 15,000 cycles\u003c\/li\u003e\n  \u003cli\u003eStandard: EN\/IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A residual current protection detects both sinusoidal AC and pulsating DC fault currents\u003c\/li\u003e\n  \u003cli\u003eInstantaneous tripping ensures rapid disconnection on fault detection\u003c\/li\u003e\n  \u003cli\u003eIndependent tripping technology operates without reliance on the supply voltage\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides clear visual status of the device\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting for fast, tool-free installation\u003c\/li\u003e\n  \u003cli\u003eLocking device option available for enhanced tamper protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFinal distribution boards in residential and commercial buildings\u003c\/li\u003e\n  \u003cli\u003eProtection of circuits supplying electronic equipment with switch-mode power supplies\u003c\/li\u003e\n  \u003cli\u003eThree-phase + neutral circuits requiring Type A residual current protection\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and modular enclosures\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring protection against indirect contact and earth leakage faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9R21425, Schneider Electric A9R21425, Acti9 iID RCCB 4P 25A 30mA Type A.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075773853960,"sku":"SCHA9R21425","price":50.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/a9r21425-residual-current-circuit-breaker-rccb-acti9-iid-4p-25a-a-type-30ma-626176.jpg?v=1735231329"},{"product_id":"a9r34491-residual-current-circuit-breaker-rccb-acti9-iid-4p-100a-a-si-type-300ma","title":"Schneider A9R34491 Acti9 iID RCCB 4P 100 A 300mA Type A-SI","description":"\u003cp\u003eThe Schneider Electric A9R34491 is a 4-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 iID range, designed for residual current protection in AC networks. Rated at 100 A with a 300 mA sensitivity and Type A-SI classification, it provides selective instantaneous tripping for reliable fault protection in distribution systems.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9R34491\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eNeutral position: Left\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 100 A\u003c\/li\u003e\n  \u003cli\u003eNetwork type: AC\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 380...415 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 300 mA\u003c\/li\u003e\n  \u003cli\u003eTripping delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eResidual current class: Type A-SI\u003c\/li\u003e\n  \u003cli\u003eRated making\/breaking capacity: Idm 1500 A, Im 1500 A\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: Click-fit on DIN rail\u003c\/li\u003e\n  \u003cli\u003eDIN rail rows: 9 mm, 8 modules\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 72 x 91 x 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.37 kg\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 (IEC 60529), IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40...85 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block upper or lower, 1...35 mm² rigid \/ 1...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eStandards: EN\/IEC 61008-1, EN\/IEC 61008-2-1\u003c\/li\u003e\n  \u003cli\u003eCertifications: CCC\u003c\/li\u003e\n  \u003cli\u003eEMC: 8\/20 µs withstand current impulse 3000 A per EN\/IEC 61008-1\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance (AC-1): 10,000 cycles\u003c\/li\u003e\n  \u003cli\u003eColour: White\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A-SI classification provides selective protection against both sinusoidal and pulsating DC residual currents\u003c\/li\u003e\n  \u003cli\u003eInstantaneous tripping ensures fast disconnection upon detection of residual fault currents\u003c\/li\u003e\n  \u003cli\u003eClick-fit DIN rail mounting enables quick and tool-free installation in modular enclosures\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides immediate visual confirmation of device status\u003c\/li\u003e\n  \u003cli\u003eIndependent tripping technology ensures operation is not affected by supply voltage conditions\u003c\/li\u003e\n  \u003cli\u003eLocking device option supports lockout\/tagout procedures for maintenance safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain residual current protection in final distribution boards for commercial and industrial installations\u003c\/li\u003e\n  \u003cli\u003eProtection of downstream circuits in three-phase and neutral AC distribution systems\u003c\/li\u003e\n  \u003cli\u003eSelective coordination in tiered protection schemes requiring Type A-SI devices\u003c\/li\u003e\n  \u003cli\u003ePanel boards in buildings where protection against pulsating DC fault currents is required\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation panels requiring reliable earth fault protection at 100 A load levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9R34491, Schneider Electric A9R34491, Schneider RCCB 4P 100A 300mA, Acti9 iID residual current device.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075781456136,"sku":"SCHA9R34491","price":107.68,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9r34491-residual-current-circuit-breaker-rccb-acti9-iid-4p-100a-a-si-type-300ma-391000.jpg?v=1745850471"},{"product_id":"a9r61240-residual-current-circuit-breaker-rccb-acti9-iid-2p-40a-a-si-type-30ma","title":"Schneider A9R61240 Acti9 iID RCCB 2P 40 A 30mA Type A-SI","description":"\u003cp\u003eThe Schneider Electric A9R61240 is a 2-pole 40 A Residual Current Circuit Breaker (RCCB) from the Acti 9 iID range, offering 30 mA sensitivity with Type A-SI residual current protection. It delivers instantaneous tripping for reliable disconnection against earth faults in AC electrical distribution systems.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9R61240\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 40 A\u003c\/li\u003e\n  \u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eResidual current class: Type A-SI\u003c\/li\u003e\n  \u003cli\u003eTrip delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 220...240 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage [Ui]: 500 V AC 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated making\/breaking capacity: Idm 1500 A, Im 1500 A\u003c\/li\u003e\n  \u003cli\u003eImpulse current withstand: 3000 A (8\/20 µs per EN\/IEC 61008-1)\u003c\/li\u003e\n  \u003cli\u003eMounting: Clip-on, DIN rail\u003c\/li\u003e\n  \u003cli\u003eModule width: 4 x 9 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 36 x 91 x 73.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.21 kg\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 \/ IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60 °C\u003c\/li\u003e\n  \u003cli\u003eConnection: Single terminal block upper or lower, 1...35 mm² rigid \/ 1...25 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eTightening torque: 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 15,000 cycles (AC-1)\u003c\/li\u003e\n  \u003cli\u003eCertifications: CCC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A-SI class detects both AC and pulsating DC residual fault currents for broader protection\u003c\/li\u003e\n  \u003cli\u003eInstantaneous tripping ensures fast disconnection on earth faults without intentional delay\u003c\/li\u003e\n  \u003cli\u003eContact position indicator provides at-a-glance circuit status\u003c\/li\u003e\n  \u003cli\u003eClip-on DIN rail mounting allows quick, tool-free installation in modular enclosures\u003c\/li\u003e\n  \u003cli\u003eLocking device option prevents unauthorized operation or accidental switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOutgoing protection in residential and commercial electrical distribution boards\u003c\/li\u003e\n  \u003cli\u003eCircuits supplying inverter-driven or electronic equipment that produce pulsating DC fault currents\u003c\/li\u003e\n  \u003cli\u003eFinal distribution in modular enclosures requiring IP40 protection\u003c\/li\u003e\n  \u003cli\u003eInstallations demanding high impulse current robustness and wide operating temperature range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with EN\/IEC 61008-1 and EN\/IEC 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9R61240, Schneider Electric A9R61240, Acti9 iID RCCB 2P 40A 30mA Type A-SI.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075788632328,"sku":"SCHA9R61240","price":43.12,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9r61240-residual-current-circuit-breaker-rccb-acti9-iid-2p-40a-a-si-type-30ma-864459.jpg?v=1745850458"},{"product_id":"a9tdf3616-arc-fault-detection-rcbo-acti9-icv40n-vigiarc-1p-n-16a-c-curve-30ma-type-a-si-6000a","title":"Schneider A9TDF3616 Acti9 iCV40N VigiARC RCBO 1P+N 16 A C 30mA Type A-SI","description":"\u003cp\u003eThe Schneider Electric A9TDF3616 is a 1P+N RCBO from the Acti9 iCV40N VigiARC range, rated 16 A, C curve, 30mA sensitivity, Type A-SI. It combines MCB overload\/short-circuit protection with RCD earth leakage protection in a compact 2-module (36mm) DIN rail device, providing individual circuit protection without requiring a separate RCD.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePart number: A9TDF3616\u003c\/li\u003e\n\u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli\u003eSeries: Acti9 iCV40N VigiARC\u003c\/li\u003e\n\u003cli\u003ePoles: 1P+N\u003c\/li\u003e\n\u003cli\u003eRated current: 16 A\u003c\/li\u003e\n\u003cli\u003eTripping curve: C\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30mA\u003c\/li\u003e\n\u003cli\u003eResidual current type: A-SI\u003c\/li\u003e\n\u003cli\u003eBreaking capacity: 6000A (IEC\/EN 60898-1)\u003c\/li\u003e\n\u003cli\u003eMounting: 35mm DIN rail, 18mm pitch (2 modules)\u003c\/li\u003e\n\u003cli\u003eStandards: IEC\/EN 60898-1, IEC\/EN 61009-1, CE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eType A-SI - selective (time-delayed), coordinates with upstream RCDs to prevent nuisance tripping\u003c\/li\u003e\n\u003cli\u003eCombined MCB+RCD in 2 modules - individual circuit protection without a dedicated RCD on the board incomer\u003c\/li\u003e\n\u003cli\u003eArc fault detection (AFDD) - detects series arc faults in wiring that standard MCBs cannot detect, reducing fire risk\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIndividual final circuit protection with combined overload, short-circuit, and earth leakage protection\u003c\/li\u003e\n\u003cli\u003eShower, washing machine, and socket outlet circuits requiring individual 30mA RCD protection\u003c\/li\u003e\n\u003cli\u003eDistribution boards where individual RCBO protection is preferred over grouped RCD+MCB\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Schneider A9TDF3616, Acti9 iCV40N VigiARC 1P+N 16 A C 30mA RCBO, A9TDF3616 residual current circuit breaker with overload protection.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44075817763080,"sku":"SCHA9TDF3616","price":139.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9tdf3616-arc-fault-detection-rcbo-acti9-icv40n-vigiarc-1pn-16a-c-curve-30ma-type-a-si-6000a-374451.jpg?v=1745850470"},{"product_id":"a9z51463-residual-current-circuit-breaker-rccb-acti9-iid-4p-63a-b-ev-electric-vehicle-type-30ma-double-terminal","title":"Schneider A9Z51463 Acti9 iID B-EV RCCB 4P 63 A 30mA Type B-EV","description":"\u003cp\u003eThe Schneider Electric A9Z51463 is a 4-pole Residual Current Circuit Breaker (RCCB) from the Acti 9 iID range, rated at 63 A with 30 mA differential sensitivity and Type B-EV classification for electric vehicle charging applications. It delivers instantaneous tripping with a 10 kA rated conditional short-circuit current. Quality approvals include VDE, NF, IMQ, and KEMA.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial reference: A9Z51463\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003eEAN: \u003c\/li\u003e\n  \u003cli\u003eSeries \/ range: Acti 9 iID\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB (Residual Current Circuit Breaker)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n  \u003cli\u003eRated current [In]: 63 A\u003c\/li\u003e\n  \u003cli\u003eRated voltage [Ue]: 400 V AC 50 Hz\u003c\/li\u003e\n  \u003cli\u003eDifferential sensitivity: 30 mA\u003c\/li\u003e\n  \u003cli\u003eDifferential protection class: Type B-EV\u003c\/li\u003e\n  \u003cli\u003eOperating delay: Instantaneous\u003c\/li\u003e\n  \u003cli\u003eRated conditional short-circuit current: 10 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage [Uimp]: 6 kV\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, click-on system, 8 x 9 mm modules\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 72 x 88 x 79 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 415 g\u003c\/li\u003e\n  \u003cli\u003eIP protection: IP20 \/ IP40 in modular enclosure (IEC 60529)\u003c\/li\u003e\n  \u003cli\u003eOvervoltage category: IV\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25...60 °C\u003c\/li\u003e\n  \u003cli\u003eConnection (top): up to 35 mm² rigid \/ 25 mm² flexible; tightening torque 3.5 N.m\u003c\/li\u003e\n  \u003cli\u003eConnection (bottom): up to 25 mm² rigid \/ 16 mm² flexible\u003c\/li\u003e\n  \u003cli\u003eCertifications: VDE, NF, IMQ, KEMA, CCC, KC\u003c\/li\u003e\n  \u003cli\u003eMechanical endurance: 20,000 cycles\u003c\/li\u003e\n  \u003cli\u003eElectrical endurance: 15,000 cycles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType B-EV differential protection covers AC, pulsating DC, and smooth DC residual fault currents - purpose-built for EV charger circuits\u003c\/li\u003e\n  \u003cli\u003eIndependent differential operating technology trips without relying on mains voltage\u003c\/li\u003e\n  \u003cli\u003eContact position indicator and trip indicator provide clear local ON\/OFF status reading\u003c\/li\u003e\n  \u003cli\u003eLockable handle for controlled access and safety\u003c\/li\u003e\n  \u003cli\u003eDouble-terminal connections on top and bottom allow flexible cable routing in the enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProtection of electric vehicle charging points and EV charging stations\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial LV distribution boards requiring Type B-EV RCD protection\u003c\/li\u003e\n  \u003cli\u003eOutgoing and group supply positions in modular DIN rail enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC 61008-2-1, IEC\/EN 62423, and EN 61008-2-1. Part of the Schneider Electric Acti 9 range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Schneider A9Z51463, Schneider Electric A9Z51463, Acti9 iID B-EV RCCB 4P 63A 30mA.\u003c\/p\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":44076014174472,"sku":"SCHA9Z51463","price":301.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/products\/a9z51463-residual-current-circuit-breaker-rccb-acti9-iid-4p-63a-b-ev-electric-vehicle-type-30ma-double-terminal-921337.jpg?v=1745850232"},{"product_id":"286492-pf6-25-2-003-residual-current-circuit-breaker-2p-25a-30ma","title":"Eaton 286492 PF6-25\/2\/003 RCCB 2P 25 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-25\/2\/003 is a 2-pole Type AC RCCB from the Moeller series xPole range, rated at 25 A with a 30 mA fault current threshold and 6 kA breaking capacity. Partly surge-proof at 250 A, it protects residential and commercial circuits from earth leakage currents on standard DIN rail.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-25\/2\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286492\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082864927\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eResidual current (IN): 30 mA, Type AC\u003c\/li\u003e\n  \u003cli\u003eBreaking capacity (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC, 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eSurge protection: Partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eBack-up fuse: max. 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm; built-in width: 2 SU (35 mm)\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 55 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConductor cross section (solid-core): 1.5-35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross section (multi-wired): 1.5-16 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminals: Open mouthed\/lift, touch safe, EN 50274\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensitivity detects sinusoidal AC residual currents reliably\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping from transient currents\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals comply with DGUV VS3 and EN 50274\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-FW\/LP remote control device and Z-RC\/AK-2TE sealing cover accessories\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail attachment with 2 latch positions for fast and secure installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth leakage protection in residential consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical distribution boards and panels\u003c\/li\u003e\n  \u003cli\u003eOffice and retail final circuit protection\u003c\/li\u003e\n  \u003cli\u003ePanel assemblies using the KLV-TC-2 compact enclosure\u003c\/li\u003e\n  \u003cli\u003eCircuits requiring remote switching via Z-FW\/LP automatic switching device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-25\/2\/003, Eaton 286492, Eaton catalog 286492, Eaton model PF6-25\/2\/003, Eaton xPole 25A 2-pole RCCB 30mA.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251474886920,"sku":"ETN286492","price":16.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286492-pf6-252003-residual-current-circuit-breaker-2p-25a-30ma-877687.jpg?v=1735225452"},{"product_id":"286496-pf6-40-2-003-residual-current-circuit-breaker-2p-40a-30ma","title":"Eaton 286496 PF6-40\/2\/003 RCCB 2P 40 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-40\/2\/003 is a 2-pole residual current circuit breaker (RCCB) from the Eaton Moeller xPole series, rated at 40 A with a 30 mA trip threshold and Type AC sensitivity. It delivers a conditional short-circuit current rating of 6 kA and is partly surge-proof up to 250 A for reliable earth leakage protection in residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-40\/2\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286496\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082864965\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB, Type AC\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eRated residual operating current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eConditional short-circuit rating (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: Partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse (overload): max 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eShort-circuit rating (max. back-up fuse): 63 A\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 35 mm (2 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25-55 °C \/ 90-95% relative humidity per IEC 60068-2\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (solid): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross-section (multi-wire): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminal type: Open mouthed\/lift terminals\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: Finger and hand touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 - 250 V AC\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 5.8 W\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eCertification: IEC\/EN 61008\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePartly surge-proof up to 250 A reduces nuisance tripping caused by transient impulse currents\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail attachment with 2 latch positions enables fast, tool-free installation\u003c\/li\u003e\n  \u003cli\u003eOpen mouthed\/lift terminals accept solid conductors up to 35 mm² for flexible wiring\u003c\/li\u003e\n  \u003cli\u003eCompatible with optional accessories: remote control device Z-FW\/LP 248296, sealing cover set Z-RC\/AK-2TE 285385, and tripping signal contact Z-NHK 248434\u003c\/li\u003e\n  \u003cli\u003eWide operating range from -25 °C to 60 °C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eFinger and hand touch-safe terminal design per DGUV VS3 and EN 50274 for enhanced installer safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePersonal protection against earth faults in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial installations requiring 30 mA residual current protection per local wiring regulations\u003c\/li\u003e\n  \u003cli\u003eFinal circuits supplying socket outlets, bathroom equipment, and outdoor loads\u003c\/li\u003e\n  \u003cli\u003eUse with compact enclosure KLV-TC-2 276240 for pre-assembled distribution assemblies\u003c\/li\u003e\n  \u003cli\u003eRetrofit installations where surge-robust residual current protection is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-40\/2\/003, Eaton 286496, Eaton catalog 286496, Eaton model PF6-40\/2\/003, Eaton xPole RCCB 40 A 30 mA 2-pole, Eaton Moeller PF6 RCCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251474985224,"sku":"ETN286496","price":20.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286496-pf6-402003-residual-current-circuit-breaker-2p-40a-30ma-664645.jpg?v=1735225452"},{"product_id":"286500-pf6-63-2-003-residual-current-circuit-breaker-2p-63a-30ma","title":"Eaton 286500 PF6-63\/2\/003 RCCB 2P 63 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-63\/2\/003 is a two-pole Type AC residual current circuit breaker from the Moeller series xPole range, providing earth leakage protection in residential and commercial installations. Rated at 63 A with a 30 mA residual operating current and 6 kA short-circuit rating, it is partly surge-proof to 250 A for reduced nuisance tripping. DIN rail mounting in a compact 2 SU width makes it easy to integrate into standard switchgear assemblies.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-63\/2\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286500\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865009\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 63 A\u003c\/li\u003e\n  \u003cli\u003eResidual operating current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: AC\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icw): 6 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: 250 A (partly surge-proof)\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 V AC - 250 V AC\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: 40 A gG\/gL max\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 35 mm (2 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25 - 55 °C \/ 90 - 95% relative humidity (IEC 60068-2)\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section, solid-core: 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section, multi-wired: 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eTerminal type: Open mouthed\/lift terminals, finger and touch safe (DGUV VS3, EN 50274)\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 9.7 W\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n  \u003cli\u003eAccessories required: Z-HK 248432\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensitivity detects sinusoidal residual fault currents for standard residential and commercial circuit protection\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping caused by transient current impulses\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail attachment with 2 latch positions enables fast installation without additional tools\u003c\/li\u003e\n  \u003cli\u003eFinger and touch-safe terminals comply with DGUV VS3 and EN 50274 for safe wiring work\u003c\/li\u003e\n  \u003cli\u003eWide operating range of -25 °C to 60 °C suits demanding panel environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with xPole accessories including remote control device Z-FW\/LP (248296) and sealing cover Z-RC\/AK-2TE (285385)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth leakage protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eMain or sub-circuit RCCB in commercial electrical installations\u003c\/li\u003e\n  \u003cli\u003eFinal circuit protection up to 63 A alongside MCBs in DIN rail assemblies\u003c\/li\u003e\n  \u003cli\u003eIntegration into compact enclosures such as KLV-TC-2 (catalog 276240)\u003c\/li\u003e\n  \u003cli\u003eSwitchgear panels requiring Type AC residual current protection with surge immunity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-63\/2\/003, Eaton 286500, Eaton catalog 286500, Eaton model PF6-63\/2\/003, Eaton xPole RCCB 63A 30mA, Eaton Moeller PF6 RCCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475017992,"sku":"ETN286500","price":31.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286500-pf6-632003-residual-current-circuit-breaker-2p-63a-30ma-652634.jpg?v=1735225452"},{"product_id":"286504-pf6-25-4-003-residual-current-circuit-breaker-4p-25a-30ma","title":"Eaton 286504 PF6-25\/4\/003 RCCB 4P 25 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-25\/4\/003 is a four-pole Type AC residual current circuit breaker from the Moeller series xPole range, rated at 25 A with 30 mA fault-current sensitivity. It carries a 6 kA conditional short-circuit rating and is partly surge-proof to 250 A, protecting residential and commercial 230\/400 V AC circuits against earth faults.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-25\/4\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286504\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865047\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: Four-pole\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eFault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eConditional short-circuit current (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 55 °C\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid-core): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (multi-wired): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eMax. admissible back-up fuse: 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: Finger and hand touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensitivity detects sinusoidal alternating residual currents for reliable earth-fault protection\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof to 250 A, reducing nuisance tripping caused by transient overvoltages\u003c\/li\u003e\n  \u003cli\u003eQuick snap-on DIN rail attachment with 2 latch positions for fast installation\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals accept conductors from 1.5 to 35 mm²\u003c\/li\u003e\n  \u003cli\u003eWide temperature range of -25 °C to 55 °C with IEC 60068-2 climatic proofing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential distribution boards and consumer unit sub-circuits\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical installations requiring 30 mA earth-fault protection\u003c\/li\u003e\n  \u003cli\u003eCircuits protected by back-up fuses up to 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eSystems integrating the Z-FW\/LP remote switching device or KLV-TC-4 compact enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole PF6\/7 RCCB range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-25\/4\/003, Eaton 286504, Eaton catalog 286504, Eaton model PF6-25\/4\/003, xPole RCCB 25A 4-pole 30mA Type AC.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475083528,"sku":"ETN286504","price":20.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286504-pf6-254003-residual-current-circuit-breaker-4p-25a-30ma-964628.jpg?v=1735225455"},{"product_id":"286508-pf6-40-4-003-residual-current-circuit-breaker-4p-40a-30ma","title":"Eaton 286508 PF6-40\/4\/003 RCCB 4P 40 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF6-40\/4\/003 is a four-pole Type AC residual current circuit breaker (RCCB) from the Eaton Moeller series xPole range, providing earth-fault protection in residential and commercial installations. Rated at 40 A with a 30 mA residual operating current and a conditional short-circuit rating of 6 kA, it delivers reliable protection against indirect contact and fire hazards. Partly surge-proof to 250 A, it minimises nuisance tripping caused by transient discharge currents.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-40\/4\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286508\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865085\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eResidual operating current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: AC\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icw): 6 kA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 - 440 V AC\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: max 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eShort-circuit rating: 63 A (max. admissible back-up fuse)\u003c\/li\u003e\n  \u003cli\u003eMounting method: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 70 mm (4 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eTerminals: open mouthed\/lift terminals\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: finger and hand touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section solid-core: 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section multi-wired: 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003ePermitted storage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25 - 55 °C \/ 90 - 95% relative humidity (IEC 60068-2)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 13.1 W\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS conform\u003c\/li\u003e\n  \u003cli\u003eAccessories required: Z-HK 248432\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping from transient discharge currents\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals (DGUV VS3, EN 50274) for safer wiring\u003c\/li\u003e\n  \u003cli\u003eWide conductor range (1.5 - 35 mm² solid-core) suits diverse cable configurations\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail snap-on with 2 latch positions enables fast panel assembly\u003c\/li\u003e\n  \u003cli\u003eCompatible with remote control and automatic switching device Z-FW\/LP 248296\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range (-25 °C to 60 °C) suits varied installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth-fault protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building sub-distribution panels in offices, retail, and hotels\u003c\/li\u003e\n  \u003cli\u003eProtection of socket outlet circuits and fixed appliance circuits\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring remote or automated RCD switching\u003c\/li\u003e\n  \u003cli\u003eLight industrial premises requiring Type AC RCCB protection to IEC\/EN 61008\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole switchgear range, designed for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-40\/4\/003, Eaton 286508, Eaton catalog 286508, Eaton model PF6-40\/4\/003, Eaton xPole RCCB 40 A 4-pole 30 mA Type AC.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475149064,"sku":"ETN286508","price":25.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286508-pf6-404003-residual-current-circuit-breaker-4p-40a-30ma-144365.jpg?v=1735225450"},{"product_id":"286512-pf6-63-4-003-residual-current-circuit-breaker-4p-63a-30ma","title":"Eaton 286512 PF6-63\/4\/003 RCCB 4P 63 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe PF6-63\/4\/003 is a four-pole Type AC residual current circuit breaker (RCCB) from Eaton's Moeller xPole series, rated at 63 A with a 30 mA fault current threshold for reliable earth fault protection. With a 6 kA short-circuit rating and partial surge immunity up to 250 A, it is suited for residential and commercial low-voltage distribution boards. Quick DIN rail attachment and finger-safe open mouthed lift terminals simplify installation in switchgear assemblies up to 400 V AC.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-63\/4\/003\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 286512\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082865122\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB, Type AC, AC current sensitive\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 63 A\u003c\/li\u003e\n  \u003cli\u003eFault current rating (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eShort-circuit rating (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: 250 A (partly surge-proof)\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 V AC - 440 V AC\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: max 40 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25-55 °C \/ 90-95% relative humidity per IEC 60068-2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 70 mm (4 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (L x H x W): 76 x 80 x 70 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor, multi-wire: 1.5 mm² - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor, solid-core: 1.5 mm² - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 mm - 2 mm\u003c\/li\u003e\n  \u003cli\u003eTerminal type: Open mouthed\/lift terminals\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: Finger and hand touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 13.4 W\u003c\/li\u003e\n  \u003cli\u003eAccessories required: Z-HK 248432\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC sensing detects sinusoidal AC residual fault currents\u003c\/li\u003e\n  \u003cli\u003ePartial surge protection up to 250 A reduces nuisance tripping from transient currents\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail latch with 2 positions enables fast, secure panel installation\u003c\/li\u003e\n  \u003cli\u003eFinger and touch-safe open mouthed lift terminals comply with EN 50274 and DGUV VS3\u003c\/li\u003e\n  \u003cli\u003eOperating range down to -25 °C suits installations in unheated environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-NHK 248434 tripping signal contact and Z-FW\/LP 248296 remote control for extended functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault protection in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical panels requiring 30 mA RCD protection\u003c\/li\u003e\n  \u003cli\u003eLow-voltage switchgear assemblies operating at 230 V AC or 400 V AC\u003c\/li\u003e\n  \u003cli\u003eRetrofit into DIN rail enclosures such as the KLV-TC-4 276241 compact enclosure\u003c\/li\u003e\n  \u003cli\u003eInstallations where partial surge immunity is required to prevent spurious tripping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008, RoHS conform. Part of the Eaton Moeller xPole series of residual current circuit breakers.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-63\/4\/003, Eaton 286512, Eaton catalog 286512, Eaton model PF6-63\/4\/003, Eaton xPole RCCB 63A 4P 30mA, Eaton Moeller PF6 four-pole RCCB.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44251475214600,"sku":"ETN286512","price":40.84,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/286512-pf6-634003-residual-current-circuit-breaker-4p-63a-30ma-847982.jpg?v=1735325460"},{"product_id":"112921-pf6-25-2-003-a-residual-current-circuit-breaker-2p-25a-30ma-type-a","title":"Eaton 112921 PF6-25\/2\/003-A RCCB 2P 25 A 30mA Type A DIN Rail","description":"\u003cp\u003eThe Eaton PF6-25\/2\/003-A is a two-pole Type A RCCB from the Moeller series xPole range, rated 25 A \/ 30 mA with a 6 kA short-circuit rating. Pulse-current sensitive and partly surge-proof to 250 A, it protects residential and commercial circuits against AC and pulsating DC residual currents.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-25\/2\/003-A\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 112921\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015081124596\u003c\/li\u003e\n  \u003cli\u003ePoles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eResidual current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: A, pulse-current sensitive\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icw): 6 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC, 50 Hz\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 35 x 80 x 76 mm (2 SU); built-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +55 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -35 °C to +60 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid): 1.5-35 mm²; (multi-wired): 1.5-16 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminals: open mouthed\/lift, touch safe per EN 50274, DGUV VS3\u003c\/li\u003e\n  \u003cli\u003eBack-up fuse: max 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations; electrical: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 2 W\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A pulse-current sensitivity detects both AC and pulsating DC residual currents for broad fault protection\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping from transient impulse currents\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail attachment with 2 latch positions enables fast, secure panel installation\u003c\/li\u003e\n  \u003cli\u003eTouch safe terminals (EN 50274, DGUV VS3) reduce risk during wiring and maintenance\u003c\/li\u003e\n  \u003cli\u003eAccepts Z-FW\/LP remote control device and KLV-TC-2 compact enclosure accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential final circuit and socket outlet residual current protection\u003c\/li\u003e\n  \u003cli\u003eCommercial building distribution board installations\u003c\/li\u003e\n  \u003cli\u003eCircuits supplying electronic equipment with inverters or variable-speed drives\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring Type A RCCB protection per IEC\/EN 61008\u003c\/li\u003e\n  \u003cli\u003eDIN rail switchgear assemblies in residential and commercial enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008 and RoHS. Part of the Eaton Moeller series xPole PF6\/7 RCCB family for residential and commercial switchgear.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-25\/2\/003-A, Eaton 112921, Eaton catalog 112921, Eaton model PF6-25\/2\/003-A, Eaton xPole 2-pole RCCB 25A 30mA Type A.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44256574767368,"sku":"ETN112921","price":20.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/112921-pf6-252003-a-residual-current-circuit-breaker-2p-25a-30ma-type-a-652392.jpg?v=1735223936"},{"product_id":"112924-pf6-40-2-003-a-residual-current-circuit-breaker-2p-40a-30ma-type-a","title":"Eaton 112924 PF6-40\/2\/003-A RCCB 2P 40 A 30mA Type A DIN Rail","description":"\u003cp\u003eThe Eaton PF6-40\/2\/003-A is a 2-pole residual current circuit breaker (RCCB) from the Eaton Moeller xPole series, designed for residential and commercial electrical installations. Rated at 40 A with a 30 mA residual operating current and a conditional short-circuit rating (Icn) of 6 kA, it provides Type A pulse-current-sensitive protection. The device is partly surge-proof up to 250 A, maintaining reliable operation in installations subject to transient impulse currents.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-40\/2\/003-A\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 112924\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015081124626\u003c\/li\u003e\n  \u003cli\u003eProduct type: RCCB\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 230 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eResidual operating current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: Type A\u003c\/li\u003e\n  \u003cli\u003eSensitivity: Pulse-current sensitive\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icw): 6 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: Partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 35 mm (2 SU)\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (IEC\/EN 60715), quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003ePermitted storage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25-55 °C \/ 90-95% relative humidity per IEC 60068-2\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross section (solid-core): 1.5 mm² - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor cross section (multi-wired): 1.5 mm² - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminal type: Open mouthed\/lift terminals\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: Finger and touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 V AC - 250 V AC\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse (overload): max 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eMax admissible back-up fuse (short-circuit): 63 A\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 mm - 2 mm\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 5.8 W\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eFitted with: Interlocking device IS\/SPE-1TE 101911\u003c\/li\u003e\n  \u003cli\u003eRequired accessory: Z-HK 248432\u003c\/li\u003e\n  \u003cli\u003eCertification: IEC\/EN 61008\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A pulse-current-sensitive detection per IEC\/EN 61008 for enhanced residual current protection in modern residential circuits\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof at 250 A, reducing the risk of nuisance tripping from transient impulse currents\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail attachment with 2 latch positions enables fast, secure panel assembly\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals compliant with DGUV VS3 and EN 50274 for safe installation and maintenance\u003c\/li\u003e\n  \u003cli\u003eWide ambient operating range of -25 °C to 60 °C suits diverse installation environments\u003c\/li\u003e\n  \u003cli\u003eTripping signal contact for subsequent installation of Z-NHK 248434; compatible with Z-FW\/LP 248296 remote control and automatic switching device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidual current protection in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eEarth fault protection in commercial electrical panel installations\u003c\/li\u003e\n  \u003cli\u003eInstallation within compact enclosures such as KLV-TC-2 (catalog 276240)\u003c\/li\u003e\n  \u003cli\u003eDIN rail switchgear panels requiring IEC\/EN 61008-compliant RCCB protection\u003c\/li\u003e\n  \u003cli\u003exPole switchgear systems for residential and commercial building electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-40\/2\/003-A, Eaton 112924, Eaton catalog 112924, Eaton model PF6-40\/2\/003-A, Eaton xPole RCCB 40A 2P 30mA Type A.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44256574898440,"sku":"ETN112924","price":25.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/112924-pf6-402003-a-residual-current-circuit-breaker-2p-40a-30ma-type-a-219100.jpg?v=1735223936"},{"product_id":"112930-pf6-25-4-003-a-residual-current-circuit-breaker-4p-25a-30ma-type-a","title":"Eaton 112930 PF6-25\/4\/003-A RCCB 4P 25 A 30mA Type A DIN Rail","description":"\u003cp\u003eThe Eaton PF6-25\/4\/003-A is a 4-pole RCCB from the Moeller series xPole range, rated 25 A with a 30 mA residual operating current and a 6 kA conditional short-circuit current. Type A and pulse-current sensitive, it detects both sinusoidal AC and pulsating DC fault currents, making it suitable for residential and commercial distribution boards.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-25\/4\/003-A\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 112930\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015081124688\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eResidual operating current (IΔN): 30 mA, Type A\u003c\/li\u003e\n  \u003cli\u003eConditional short-circuit current (Icn): 6 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 70 x 80 x 76 mm, 4 SU\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (IEC\/EN 60715), quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eTerminals: open mouthed\/lift, solid-core 1.5 - 35 mm², multi-wired 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: finger and hand touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 55 °C\u003c\/li\u003e\n  \u003cli\u003eStorage\/transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 3.1 W\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 V AC - 440 V AC\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A sensitivity detects pulsating DC residual currents generated by inverters, dimmers, and switch-mode power supplies\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping caused by transient overvoltages\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals (DGUV VS3, EN 50274) protect installers during wiring and commissioning\u003c\/li\u003e\n  \u003cli\u003eQuick snap-on DIN-rail mounting with 2 latch positions speeds up panel assembly\u003c\/li\u003e\n  \u003cli\u003eCompatible with optional Z-FW\/LP 248296 remote control and automatic switching device for automated operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential consumer units and distribution boards requiring 4-pole earth leakage protection\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical installations with mixed single-phase and three-phase loads\u003c\/li\u003e\n  \u003cli\u003eCircuits supplying frequency converters, motor drives, or switched-mode power supplies\u003c\/li\u003e\n  \u003cli\u003eFinal circuits where Type A RCCB protection is required by local wiring regulations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole PF6\/7 RCCB range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-25\/4\/003-A, Eaton 112930, Eaton catalog 112930, Eaton model PF6-25\/4\/003-A, Eaton xPole 4-pole 25 A RCCB 30 mA Type A.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44256575324424,"sku":"ETN112930","price":22.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/112930-pf6-254003-a-residual-current-circuit-breaker-4p-25a-30ma-type-a-864331.jpg?v=1735223936"},{"product_id":"112933-pf6-40-4-003-a-residual-current-circuit-breaker-4p-40a-30ma-type-a","title":"Eaton 112933 PF6-40\/4\/003-A RCCB 4P 40 A 30mA Type A DIN Rail","description":"\u003cp\u003eThe Eaton PF6-40\/4\/003-A is a 4-pole, 40 A residual current circuit breaker (RCCB) from the Eaton Moeller xPole series, offering 30 mA type A trip sensitivity for 230 V AC \/ 400 V AC systems. Designed for DIN rail installation in residential and commercial switchboards, it provides reliable earth leakage protection with a mechanical lifespan of 20,000 operations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-40\/4\/003-A\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 112933\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015081124718\u003c\/li\u003e\n  \u003cli\u003eRated current: 40 A\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eFault current: 30 mA, type A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icw): 6 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: partly surge-proof, 250 A\u003c\/li\u003e\n  \u003cli\u003eMax. admissible back-up fuse: 63 A\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 70 mm (4 SU)\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid-core): 1.5-35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (multi-wired): 1.5-16 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminal protection: finger and touch safe, DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eTerminals: open mouthed\/lift type\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A sensitivity detects both sinusoidal AC and pulsating DC residual currents, covering a wider range of fault types than type AC devices\u003c\/li\u003e\n  \u003cli\u003ePartly surge-proof with 250 A impulse withstand current, reducing nuisance tripping from transient surges\u003c\/li\u003e\n  \u003cli\u003eCurrent derating above 40 °C: rated continuous current decreases by 2.5% per 1 °C, permitting operation up to 60 °C ambient\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail snap-on attachment with two latch positions for fast, flexible panel assembly\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-FW\/LP remote control device and Z-RC\/AK-4TE sealing cover for enhanced functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential consumer units and main distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial and light industrial switchgear panels\u003c\/li\u003e\n  \u003cli\u003eProtection of socket outlet circuits and fixed appliances\u003c\/li\u003e\n  \u003cli\u003eWet area and bathroom circuits requiring 30 mA personal protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole switchgear range for residential and commercial installations.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-40\/4\/003-A, Eaton 112933, Eaton catalog 112933, Eaton model PF6-40\/4\/003-A, Eaton xPole RCCB 40A 4-pole 30mA type A, PF6 40\/4\/003-A.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44256575389960,"sku":"ETN112933","price":28.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/112933-pf6-404003-a-residual-current-circuit-breaker-4p-40a-30ma-type-a-863689.jpg?v=1735223936"},{"product_id":"112936-pf6-63-4-003-a-residual-current-circuit-breaker-4p-63a-30ma-type-a","title":"Eaton 112936 PF6-63\/4\/003-A RCCB 4P 63 A 30mA Type A DIN Rail","description":"\u003cp\u003eThe Eaton PF6-63\/4\/003-A is a four-pole 63 A RCCB from the Moeller xPole series, providing Type A, pulse-current-sensitive earth fault protection for residential and commercial circuits. With a 30 mA tripping threshold and 6 kA short-circuit rating, it delivers reliable personal protection while partial surge immunity to 250 A minimizes nuisance trips from voltage transients.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF6-63\/4\/003-A\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 112936\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015081124749\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 63 A\u003c\/li\u003e\n  \u003cli\u003eRated residual operating current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eResidual current type: Type A (pulse-current sensitive)\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icw): 6 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: 250 A (partly surge-proof)\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: max. 40 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 V AC - 440 V AC\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, quick attachment with 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 70 mm (4 SU)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section, solid-core: 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section, multi-wired: 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eTerminals: open-mouth\/lift type, finger and hand touch safe (DGUV VS3, EN 50274)\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25-55 °C \/ 90-95% RH per IEC 60068-2\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eEquipment heat dissipation (current-dependent): 13.4 W\u003c\/li\u003e\n  \u003cli\u003eRequired accessory: Z-HK 248432\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A sensitivity trips on both sinusoidal AC and pulsating DC residual currents, protecting circuits with modern electronic loads and rectifier-fed equipment\u003c\/li\u003e\n  \u003cli\u003ePartial surge immunity to 250 A reduces nuisance tripping caused by transient overvoltages common in residential installations\u003c\/li\u003e\n  \u003cli\u003eRated for continuous operation up to 60 °C ambient; above 40 °C, permissible current decreases by 1.8% per °C to maintain safe operation\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open-mouth\/lift terminals accept solid-core conductors up to 35 mm², simplifying termination without additional tooling\u003c\/li\u003e\n  \u003cli\u003eTwo-latch DIN rail snap-on attachment speeds panel assembly and enables straightforward field replacement\u003c\/li\u003e\n  \u003cli\u003eCompatible with optional interlocking device IS\/SPE-1TE 101911 and tripping signal contact Z-NHK 248434 for advanced panel configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMain or sub-circuit residual current protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial switchgear panels requiring four-pole 63 A RCCB protection across three-phase and neutral\u003c\/li\u003e\n  \u003cli\u003eCircuits supplying inverter-driven equipment, heat pumps, or EV charging points that generate pulsating DC leakage currents\u003c\/li\u003e\n  \u003cli\u003eHigh-ambient-temperature enclosures and mixed residential-commercial panels operating up to 60 °C\u003c\/li\u003e\n  \u003cli\u003eDIN rail assemblies within compact enclosures such as the Eaton KLV-TC-4 (276241)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole switchgear range for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF6-63\/4\/003-A, Eaton 112936, Eaton catalog 112936, Eaton model PF6-63\/4\/003-A, Eaton xPole RCCB 63A 4-pole 30mA Type A.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44256575488264,"sku":"ETN112936","price":43.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/112936-pf6-634003-a-residual-current-circuit-breaker-4p-63a-30ma-type-a-519420.jpg?v=1735223936"},{"product_id":"411509-tx-residual-current-circuit-breaker-2p-25a-30ma-id","title":"Legrand 411509 RCCB TX³ 2P 25A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Legrand 411509 (catalog reference 4 115 09) is a TX³ residual current circuit breaker (RCCB), 2-pole, rated 25 A with 30 mA AC-type sensitivity for 230 V~ installations. It occupies 2 modules on a DIN rail and conforms to IEC 61008-1, providing personal protection from direct and indirect contact along with insulation-fault protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCatalog reference: 411509\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n  \u003cli\u003eEAN: 3414970352408\u003c\/li\u003e\n  \u003cli\u003eProduct type: TX³ RCCB (residual current circuit breaker)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 230 V~ (operating range 180-250 V~)\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eRated residual current (IΔn): 30 mA (0.03 A)\u003c\/li\u003e\n  \u003cli\u003eResidual current type: AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 250 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eShort-circuit conditional capacity (Icw): 10 kA\u003c\/li\u003e\n  \u003cli\u003eSurge current capacity: 0.25 kA\u003c\/li\u003e\n  \u003cli\u003eWidth: 2 modules \/ 35.6 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 88.9 mm; depth: 77.8 mm; built-in depth: 44 mm\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (EN 60715 \/ DIN 35)\u003c\/li\u003e\n  \u003cli\u003eConnection: screw terminals; busbar and cable compatible\u003c\/li\u003e\n  \u003cli\u003eCable cross-section: 0.75 to 50 mm² solid-core, 0.75 to 35 mm² multi-wired\u003c\/li\u003e\n  \u003cli\u003eCompatible with prong-type and fork-type supply busbars\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eImpact resistance: IK04\u003c\/li\u003e\n  \u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n  \u003cli\u003eAmbient temperature (operating): -25 to +60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to +70 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eHalogen-free\u003c\/li\u003e\n  \u003cli\u003eStandard: IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eElectromagnetic residual current sensing detects insulation faults and protects people from direct and indirect contact in IT, TT, and TN earthing systems.\u003c\/li\u003e\n  \u003cli\u003eInterlocking device supports lockout\/tagout procedures during maintenance.\u003c\/li\u003e\n  \u003cli\u003eBidirectional supply allows the device to be wired from the top or bottom of the enclosure.\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction reduces toxic emissions in the event of fire.\u003c\/li\u003e\n  \u003cli\u003eProng and fork busbar compatibility speeds up distribution-board assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential and commercial distribution boards requiring 30 mA residual-current personal protection.\u003c\/li\u003e\n  \u003cli\u003eInsulation-fault protection for lighting circuits, socket outlets, and general-purpose feeders.\u003c\/li\u003e\n  \u003cli\u003eSelective coordination with upstream protective devices in IT, TT, and TN-S supply systems.\u003c\/li\u003e\n  \u003cli\u003eDIN rail enclosures specifying a 2-module-wide 25 A RCCB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: Legrand 411509, TX³ RCCB 2P 25A 30mA Type AC, 4 115 09.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":44261650137352,"sku":"LGR411509","price":24.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/411509-tx3-residual-current-circuit-breaker-2p-25a-30ma-id-902141.jpg?v=1735226572"},{"product_id":"411510-tx-residual-current-circuit-breaker-2p-40a-30ma-id","title":"Legrand 411510 RCCB TX³ 2P 40A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Legrand 411510 (catalog reference 4 115 10) is a TX³ residual current circuit breaker (RCCB), 2-pole, rated 40 A with 30 mA AC-type sensitivity for 230 V~ installations. It occupies 2 modules on a DIN rail and conforms to IEC 61008-1, providing personal protection from direct and indirect contact along with insulation-fault protection.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCatalog reference: 411510\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n  \u003cli\u003eEAN: 3414970352422\u003c\/li\u003e\n  \u003cli\u003eProduct type: TX³ RCCB (residual current circuit breaker)\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 2\u003c\/li\u003e\n  \u003cli\u003eRated voltage: 230 V~ (operating range 180-250 V~)\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eRated residual current (IΔn): 30 mA (0.03 A)\u003c\/li\u003e\n  \u003cli\u003eResidual current type: AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated insulation voltage (Ui): 250 V\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eShort-circuit conditional capacity (Icw): 10 kA\u003c\/li\u003e\n  \u003cli\u003eSurge current capacity: 0.25 kA\u003c\/li\u003e\n  \u003cli\u003eWidth: 2 modules \/ 35.6 mm\u003c\/li\u003e\n  \u003cli\u003eHeight: 88.9 mm; depth: 77.8 mm; built-in depth: 44 mm\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (EN 60715 \/ DIN 35)\u003c\/li\u003e\n  \u003cli\u003eConnection: screw terminals; busbar and cable compatible\u003c\/li\u003e\n  \u003cli\u003eCable cross-section: 0.75 to 50 mm² solid-core, 0.75 to 35 mm² multi-wired\u003c\/li\u003e\n  \u003cli\u003eCompatible with prong-type and fork-type supply busbars\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20\u003c\/li\u003e\n  \u003cli\u003eImpact resistance: IK04\u003c\/li\u003e\n  \u003cli\u003eColour: Grey (RAL 7035)\u003c\/li\u003e\n  \u003cli\u003eAmbient temperature (operating): -25 to +60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage temperature: -40 to +70 °C\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eHalogen-free\u003c\/li\u003e\n  \u003cli\u003eStandard: IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eElectromagnetic residual current sensing detects insulation faults and protects people from direct and indirect contact in IT, TT, and TN earthing systems.\u003c\/li\u003e\n  \u003cli\u003eInterlocking device supports lockout\/tagout procedures during maintenance.\u003c\/li\u003e\n  \u003cli\u003eBidirectional supply allows the device to be wired from the top or bottom of the enclosure.\u003c\/li\u003e\n  \u003cli\u003eHalogen-free construction reduces toxic emissions in the event of fire.\u003c\/li\u003e\n  \u003cli\u003eProng and fork busbar compatibility speeds up distribution-board assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential and commercial distribution boards requiring 30 mA residual-current personal protection.\u003c\/li\u003e\n  \u003cli\u003eInsulation-fault protection for higher-current circuits (cookers, water heaters, EV charge points) up to 40 A.\u003c\/li\u003e\n  \u003cli\u003eSelective coordination with upstream protective devices in IT, TT, and TN-S supply systems.\u003c\/li\u003e\n  \u003cli\u003eDIN rail enclosures specifying a 2-module-wide 40 A RCCB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: Legrand 411510, TX³ RCCB 2P 40A 30mA Type AC, 4 115 10.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":44261650202888,"sku":"LGR411510","price":24.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/411510-tx3-residual-current-circuit-breaker-2p-40a-30ma-id-564397.jpg?v=1735226569"},{"product_id":"411707-tx-residual-current-circuit-breaker-4p-25a-30ma-id","title":"Legrand 411707 RCCB TX³ 4P 25A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Legrand 411707 is a residual current device, 4-pole, rated 25 A with 30 mA AC-type sensitivity for 400 V installations. It occupies 4 modules on a DIN rail and conforms to IEC 61008-1, providing personal protection from direct and indirect contact along with insulation-fault protection.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 411707\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3414970353061\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H × D): 71.2 × 88.9 × 78.85 mm\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n\u003cli\u003eRated voltage: 400 V\u003c\/li\u003e\n\u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n\u003cli\u003eRated residual current (IΔn): 0.03 A\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage (Ui): 500 V\u003c\/li\u003e\n\u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eResidual current type: AC\u003c\/li\u003e\n\u003cli\u003eShort-circuit conditional capacity (Icw): 10 kA\u003c\/li\u003e\n\u003cli\u003eSurge current capacity: 0.25 kA\u003c\/li\u003e\n\u003cli\u003eVoltage type: AC\u003c\/li\u003e\n\u003cli\u003eInterlocking device: Yes\u003c\/li\u003e\n\u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 4\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eAmbient temperature (operating): -25 to 60 °C\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eCable cross-section (multi-wired): 0.75-35 mm²\u003c\/li\u003e\n\u003cli\u003eCable cross-section (solid-core): 0.75-50 mm²\u003c\/li\u003e\n\u003cli\u003eColour: Grey\u003c\/li\u003e\n\u003cli\u003eRAL reference: 7035\u003c\/li\u003e\n\u003cli\u003eImpact resistance (IK): IK04\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 340-440 V\u003c\/li\u003e\n\u003cli\u003eHalogen-free: Yes\u003c\/li\u003e\n\u003cli\u003eConnection type: Screwed terminal, Busbar and cable\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 61008-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eElectromagnetic residual current sensing detects insulation faults and protects people from direct and indirect contact.\u003c\/li\u003e\n\u003cli\u003eInterlocking device supports lockout\/tagout procedures during maintenance.\u003c\/li\u003e\n\u003cli\u003eHalogen-free construction reduces toxic emissions in the event of fire.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eResidential and commercial distribution boards requiring 30 mA residual-current personal protection.\u003c\/li\u003e\n\u003cli\u003eInsulation-fault protection for circuits up to 25 A.\u003c\/li\u003e\n\u003cli\u003eSelective coordination with upstream protective devices in TT and TN-S supply systems.\u003c\/li\u003e\n\u003cli\u003eDIN rail enclosures specifying a 2-module-wide RCD.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 411707, 411707, TX³ LEGRAND RCCB.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":44261650235656,"sku":"LGR411707","price":30.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/411707-tx3-residual-current-circuit-breaker-4p-25a-30ma-id-960774.jpg?v=1735226575"},{"product_id":"411708-tx-residual-current-circuit-breaker-4p-40a-30ma-id","title":"Legrand 411708 TX3 RCCB 4P 40A 30mA Type AC 6kA DIN Rail","description":"\u003cp\u003eLegrand 411708 TX3 is a 4-pole residual current circuit breaker (RCCB) providing earth-leakage protection in distribution boards. It detects residual currents to ground and disconnects the circuit within milliseconds, protecting against electric shock and reducing fire risk from earth faults. Rated 40A continuous current with 30mA sensitivity, Type AC for sinusoidal alternating residual currents.\u003c\/p\u003e\n\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart number: 411708\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eSeries: TX3\u003c\/li\u003e\n\u003cli\u003eType: Residual current circuit breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P (3P+N)\u003c\/li\u003e\n\u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n\u003cli\u003eRated sensitivity (IΔn): 30 mA\u003c\/li\u003e\n\u003cli\u003eResidual current type: AC (sinusoidal)\u003c\/li\u003e\n\u003cli\u003eRated voltage (Ue): 400 V AC\u003c\/li\u003e\n\u003cli\u003eBreaking capacity (Im): 6 kA\u003c\/li\u003e\n\u003cli\u003eTrip mechanism: Electromechanical (voltage-independent)\u003c\/li\u003e\n\u003cli\u003eTest button: Yes (monthly test recommended)\u003c\/li\u003e\n\u003cli\u003eConnection: Screw terminals up to 25 mm²\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail (35 mm)\u003c\/li\u003e\n\u003cli\u003eWidth: 4 modules (72 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage-independent tripping ensures operation even on partial supply failure\u003c\/li\u003e\n\u003cli\u003eTest button validates trip mechanism without test equipment\u003c\/li\u003e\n\u003cli\u003eSealed mechanism for long-term reliability in residential and commercial panels\u003c\/li\u003e\n\u003cli\u003eCompatible with Legrand DX3 MCBs in the same enclosure for combined RCD + overcurrent protection\u003c\/li\u003e\n\u003cli\u003eStandard 4-module width fits in any 18-module DIN rail row\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth-leakage protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eGroup RCCB protection for multiple downstream MCB circuits\u003c\/li\u003e\n\u003cli\u003eCommercial offices, retail spaces, schools, and apartment buildings\u003c\/li\u003e\n\u003cli\u003eThree-phase + neutral mains protection in industrial sub-distribution\u003c\/li\u003e\n\u003cli\u003eReplacement for older RCDs in panel upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eStandards: IEC 61008-1, EN 61008-1, IEC 60364, RoHS compliant.\u003c\/p\u003e\n\n\u003cp\u003eAlso known as: Legrand TX3 40A 30mA 4P RCCB, Legrand RCCB 411708, 4-pole 40A residual current device, Type AC RCD.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":44261650268424,"sku":"LGR411708","price":33.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/411708-tx3-residual-current-circuit-breaker-4p-40a-30ma-id-553733.jpg?v=1735226568"},{"product_id":"2csf204004r1250-fh204-ac-25-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204004R1250 F200 RCBO 1P+N 204 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB FH204 AC-25\/0.03 (article 2CSF204004R1250) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 25 A with a 30 mA trip sensitivity. It shields people and electrical installations from earth fault currents, and is designed primarily for use in domestic applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: FH200 (model FH204 AC-25\/0.03)\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204004R1250\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542893905\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eType: AC (standard instantaneous)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4-pole design disconnects all live conductors simultaneously, covering three-phase plus neutral circuits in a single device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity provides personal protection against indirect contact with live parts\u003c\/li\u003e\n\u003cli\u003eType AC operation responds to sinusoidal residual currents, which are the fault type most commonly encountered in domestic settings\u003c\/li\u003e\n\u003cli\u003ePart of the FH200 range, which covers both AC and A type variants to suit a wide variety of residential installation requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eEarth fault protection for domestic socket outlet circuits\u003c\/li\u003e\n\u003cli\u003eProtection of household appliances in kitchens, bathrooms, and utility rooms\u003c\/li\u003e\n\u003cli\u003eGeneral 4-pole RCCB earth fault protection in home electrical installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB FH204 AC-25\/0.03, FH204 AC-25\/0.03 2CSF204004R1250, ABB 2CSF204004R1250, 4-pole RCCB 25 A 30 mA Type AC, ABB FH200 RCCB.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750011695368,"sku":"ABB2CSF204004R1250","price":20.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204004r1250-fh204-ac-25003-residual-current-circuit-breaker-4p-ac-type-30-ma-251638.png?v=1735225733"},{"product_id":"2csf204004r1400-fh204-ac-40-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204004R1400 F200 RCBO 1P+N 204 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB FH204 AC-40\/0.03 (article 2CSF204004R1400) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 40 A with a 30 mA earth fault tripping threshold. It is designed to protect both people and electrical installations from fault currents flowing to earth. The Type AC tripping characteristic makes this device well suited for standard domestic installation environments.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: FH204 AC-40\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204004R1400\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542894001\u003c\/li\u003e\n\u003cli\u003eProduct family: FH200\u003c\/li\u003e\n\u003cli\u003ePoles: 4P (4-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eRated residual current: 30 mA\u003c\/li\u003e\n\u003cli\u003eTripping type: Type AC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole design protects all four conductors in a single device, covering both live and neutral conductors across the circuit\u003c\/li\u003e\n\u003cli\u003e30 mA residual current rating provides sensitive earth fault detection, safeguarding people and installations from leakage currents\u003c\/li\u003e\n\u003cli\u003eStandard instantaneous Type AC tripping covers typical earth fault conditions encountered in domestic wiring\u003c\/li\u003e\n\u003cli\u003ePart of the FH200 series, which includes both AC and A type variants across a broad range of ratings for domestic use\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDomestic distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eProtection of final circuits in residential properties and apartments\u003c\/li\u003e\n\u003cli\u003e4-pole earth fault protection in new-build and retrofit home installations\u003c\/li\u003e\n\u003cli\u003eGeneral residential electrical installations requiring standard Type AC protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB FH204 AC-40\/0.03, FH204 AC-40\/0.03 2CSF204004R1400, ABB 2CSF204004R1400, 4-pole RCCB 40 A 30 mA Type AC, FH200 4P RCCB.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750011859208,"sku":"ABB2CSF204004R1400","price":27.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204004r1400-fh204-ac-40003-residual-current-circuit-breaker-4p-ac-type-30-ma-709594.png?v=1735225733"},{"product_id":"2csf204004r1630-fh204-ac-63-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204004R1630 F200 RCBO 1P+N 204 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB FH204 AC-63\/0.03 (article 2CSF204004R1630) is a 4-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 63 A with a residual current sensitivity of 30 mA. It guards people and electrical installations from earth fault currents by disconnecting the circuit when leakage current exceeds the 30 mA threshold. Its Type AC classification means the device responds to sinusoidal alternating residual currents, as encountered in standard domestic wiring.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: FH204 AC-63\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204004R1630\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542894100\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 63 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTrip type: AC - instantaneous, sinusoidal alternating residual current\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole design disconnects all circuit conductors simultaneously on fault detection, providing complete isolation\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity trips the breaker well below current levels considered dangerous for people, supporting personal protection\u003c\/li\u003e\n\u003cli\u003eType AC operation covers sinusoidal alternating residual currents typical of standard domestic loads\u003c\/li\u003e\n\u003cli\u003ePart of the FH200 range, which spans both AC and A type variants, giving installers a consistent product family across multiple specifications\u003c\/li\u003e\n\u003cli\u003eOptimised for domestic applications, making it a straightforward fit for residential distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eResidential consumer units and distribution boards\u003c\/li\u003e\n\u003cli\u003eEarth fault protection on final sub-circuits in homes and apartments\u003c\/li\u003e\n\u003cli\u003eSocket-outlet circuits requiring protection against electric shock\u003c\/li\u003e\n\u003cli\u003eDomestic installations where a 4-pole 63 A RCCB is specified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB FH204 AC-63\/0.03, FH204 AC-63\/0.03 2CSF204004R1630, ABB 2CSF204004R1630, ABB RCCB 4P 63A 30mA Type AC, residual current circuit breaker 4 pole 63 A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750011891976,"sku":"ABB2CSF204004R1630","price":50.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204004r1630-fh204-ac-63003-residual-current-circuit-breaker-4p-ac-type-30-ma-802042.png?v=1735225733"},{"product_id":"2csf204001r1250-f204-ac-25-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204001R1250 F200 RCBO 1P+N 204 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB F204 AC-25\/0.03 (article 2CSF204001R1250) is a 4-pole residual current circuit breaker from the ABB F200 series, rated at 25 A with a 30 mA residual current sensitivity. It protects people and electrical installations by disconnecting the circuit when earth leakage current exceeds the 30 mA threshold. As a Type AC device, it is designed to detect sinusoidal alternating residual currents in standard installations.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F204 AC-25\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204001R1250\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542781202\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eOperating type: AC (standard instantaneous)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole design switches all live conductors simultaneously, covering three-phase and neutral circuits in a single device\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity threshold provides personal protection against electric shock from earth fault currents\u003c\/li\u003e\n\u003cli\u003eType AC classification makes it suited to general installations where sinusoidal AC residual currents are expected\u003c\/li\u003e\n\u003cli\u003ePart of the F200 series, which spans a broad range of instantaneous and selective AC and A type configurations\u003c\/li\u003e\n\u003cli\u003eThe wider F200 family also includes variants for special applications, allowing system designers to select the right device for each circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEarth fault protection in three-phase residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eSafeguarding personnel and fixed installations from leakage current faults\u003c\/li\u003e\n\u003cli\u003eConsumer units and switchgear panels requiring 4-pole RCCB protection at 25 A\u003c\/li\u003e\n\u003cli\u003eGeneral electrical installations where Type AC earth fault detection is appropriate\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F204 AC-25\/0.03, F204 AC-25\/0.03 2CSF204001R1250, ABB 2CSF204001R1250, 4-pole RCCB 25 A 30 mA Type AC, ABB F200 RCCB 4P 25A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750014808328,"sku":"ABB2CSF204001R1250","price":39.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204001r1250-f204-ac-25003-residual-current-circuit-breaker-4p-ac-type-30-ma-374253.png?v=1735225740"},{"product_id":"2csf204001r1400-f204-ac-40-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204001R1400 F200 RCBO 1P+N 204 A 30mA DIN Rail","description":"\u003cp\u003eABB F204 AC-40\/0.03 (article 2CSF204001R1400) is a 4-pole, 40 A residual current circuit breaker from the ABB F200 series with a 30 mA trip sensitivity. As a Type AC device, it trips on sinusoidal alternating residual currents to earth and is designed to guard both people and electrical installations against the hazards of earth leakage faults.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F204 AC-40\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204001R1400\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542781301\u003c\/li\u003e\n\u003cli\u003eType: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 4P (4-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTrip type: Type AC - standard instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole design simultaneously disconnects all live conductors, making it well suited to three-phase circuits\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity delivers the standard personal protection level against electric shock from earth fault currents\u003c\/li\u003e\n\u003cli\u003eType AC operation ensures detection of sinusoidal alternating residual fault currents\u003c\/li\u003e\n\u003cli\u003eStandard instantaneous trip characteristic from the F200 series, which also covers selective variants for tiered protection schemes\u003c\/li\u003e\n\u003cli\u003eAddresses a range of applications including special configurations supported across the broader F200 offer\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEarth fault protection in three-phase distribution boards and sub-panels\u003c\/li\u003e\n\u003cli\u003ePersonal and installation protection in commercial and light industrial premises\u003c\/li\u003e\n\u003cli\u003e4-pole residual current protection in circuits rated up to 40 A\u003c\/li\u003e\n\u003cli\u003eInstallations where sinusoidal alternating fault currents are the primary earth leakage risk\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F204 AC-40\/0.03, F204 AC-40\/0.03 2CSF204001R1400, ABB RCCB 4-pole 40A 30mA Type AC, residual current circuit breaker 40A 4P, ABB 2CSF204001R1400.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750014873864,"sku":"ABB2CSF204001R1400","price":44.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204001r1400-f204-ac-40003-residual-current-circuit-breaker-4p-ac-type-30-ma-344614.jpg?v=1735225740"},{"product_id":"2csf204001r1630-f204-ac-63-0-03-residual-current-circuit-breaker-4p-ac-type-30-ma","title":"ABB 2CSF204001R1630 F200 RCBO 1P+N 204 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB F204 AC-63\/0.03 (article 2CSF204001R1630) is a 4-pole Type AC residual current circuit breaker from the ABB F200 series, rated at 63 A with a trip sensitivity of 30 mA. It is built to guard people and electrical installations against fault currents flowing to earth, making it a direct fit for circuits where earth leakage protection is required.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F204 AC-63\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF204001R1630\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542781400\u003c\/li\u003e\n\u003cli\u003ePoles: 4P\u003c\/li\u003e\n\u003cli\u003eRated current: 63 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eOperating type: AC (sinusoidal alternating residual current)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-pole construction covers all live conductors and neutral in a single device, suited to three-phase installations\u003c\/li\u003e\n\u003cli\u003e30 mA sensitivity threshold provides personal protection against electric shock from earth fault currents\u003c\/li\u003e\n\u003cli\u003eType AC classification gives reliable trip response to sinusoidal alternating residual currents\u003c\/li\u003e\n\u003cli\u003ePart of the F200 range, which spans both standard instantaneous and selective trip variants as well as configurations for special applications\u003c\/li\u003e\n\u003cli\u003eProtects both people and connected equipment from the hazards of unintended earth fault paths\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEarth fault protection in residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eThree-phase circuits in offices, retail premises, and light industrial buildings\u003c\/li\u003e\n\u003cli\u003eSub-distribution panels requiring four-pole RCCB protection at 63 A\u003c\/li\u003e\n\u003cli\u003eInstallations where simultaneous protection of all phases plus neutral is mandatory\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F204 AC-63\/0.03, F204 AC-63\/0.03 2CSF204001R1630, ABB 4-pole RCCB 63 A 30 mA, ABB F200 series RCCB, residual current circuit breaker 2CSF204001R1630.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750014972168,"sku":"ABB2CSF204001R1630","price":62.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf204001r1630-f204-ac-63003-residual-current-circuit-breaker-4p-ac-type-30-ma-719982.jpg?v=1735225732"},{"product_id":"2csf202001r0160-f202-ac-16-0-01-residual-current-circuit-breaker-2p-ac-type-10-ma","title":"ABB 2CSF202001R0160 F200 RCBO 1P+N 0160 A 10mA DIN Rail","description":"\u003cp\u003eThe ABB F202 AC-16\/0.01 (article 2CSF202001R0160) is a 2-pole residual current circuit breaker (RCCB) from the F200 series, rated at 16 A with a residual current sensitivity of 10 mA and Type AC operation. It is designed to safeguard both people and electrical installations from dangerous fault currents flowing to earth. The 10 mA sensitivity level makes this device well suited to applications where a high degree of personal protection is needed.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F202 AC-16\/0.01\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202001R0160\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542779902\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current: 16 A\u003c\/li\u003e\n\u003cli\u003eRated residual operating current: 10 mA\u003c\/li\u003e\n\u003cli\u003eType: AC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProtects people and electrical installations against fault currents to earth, covering both personal safety and installation security\u003c\/li\u003e\n\u003cli\u003e10 mA residual current sensitivity delivers a high level of personal protection for circuits with elevated human contact risk\u003c\/li\u003e\n\u003cli\u003eType AC operation detects sinusoidal AC residual currents, the standard fault current form found in domestic and light commercial circuits\u003c\/li\u003e\n\u003cli\u003e2-pole configuration suits single-phase branch circuit protection in a compact form\u003c\/li\u003e\n\u003cli\u003ePart of the F200 series, which spans standard instantaneous and selective variants in AC and A types, plus configurations for special applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSocket outlet circuits in bathrooms, kitchens, and other locations with elevated risk of human contact with live conductors\u003c\/li\u003e\n\u003cli\u003eSingle-phase branch circuit protection in residential and light commercial buildings\u003c\/li\u003e\n\u003cli\u003eEarth leakage protection where sinusoidal AC fault currents represent the primary hazard\u003c\/li\u003e\n\u003cli\u003eAny installation requiring high-sensitivity personal protection against earth fault currents\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F202 AC-16\/0.01, F202 AC-16\/0.01 2CSF202001R0160, ABB RCCB 2P 16A 10mA Type AC, ABB earth leakage circuit breaker 16A, residual current device 10mA 16A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021296392,"sku":"ABB2CSF202001R0160","price":44.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202001r0160-f202-ac-16001-residual-current-circuit-breaker-2p-ac-type-10-ma-428311.jpg?v=1735325771"},{"product_id":"2csf202001r1250-f202-ac-25-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202001R1250 F200 RCBO 1P+N 202 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB F202 AC-25\/0.03 (article 2CSF202001R1250) is a 2-pole residual current circuit breaker (RCCB) from the F200 series, rated at 25 A with a 30 mA residual current trip threshold. It is designed to guard both people and electrical installations against fault currents flowing to earth, and responds to Type AC residual current.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F202 AC-25\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202001R1250\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542780007\u003c\/li\u003e\n\u003cli\u003eType: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003ePoles: 2P (2-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTrip type: Type AC\u003c\/li\u003e\n\u003cli\u003eProduct family: F200\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProvides protection for people and electrical installations against fault current flowing to earth, addressing both personal safety and equipment integrity.\u003c\/li\u003e\n\u003cli\u003eRated residual current of 30 mA defines the trip threshold, at which the device disconnects the circuit upon detecting earth leakage.\u003c\/li\u003e\n\u003cli\u003eType AC designation covers sensitivity to sinusoidal alternating residual currents, the type encountered in standard AC supply circuits.\u003c\/li\u003e\n\u003cli\u003e2-pole construction interrupts both live and neutral conductors in a single operation, suited to single-phase circuit protection.\u003c\/li\u003e\n\u003cli\u003ePart of the broader F200 range, which spans standard instantaneous and selective variants as well as configurations for special applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eProtection of socket-outlet and lighting circuits in homes and light commercial premises\u003c\/li\u003e\n\u003cli\u003eSingle-phase branch circuits requiring earth fault protection\u003c\/li\u003e\n\u003cli\u003eElectrical installations where protection of people against indirect contact is required\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F202 AC-25\/0.03, F202 AC-25\/0.03 2CSF202001R1250, ABB 2CSF202001R1250, RCCB 2-pole 25 A 30 mA Type AC, ABB F200 RCCB 25A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021329160,"sku":"ABB2CSF202001R1250","price":31.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202001r1250-f202-ac-25003-residual-current-circuit-breaker-2p-ac-type-30-ma-219635.jpg?v=1735225740"},{"product_id":"2csf202001r1400-f202-ac-40-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202001R1400 F200 RCBO 1P+N 202 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB F202 AC-40\/0.03 (article 2CSF202001R1400) is a 2-pole residual current circuit breaker from the ABB F200 series, rated at 40 A with a 30 mA trip sensitivity and Type AC residual current detection. It is designed to protect both people and electrical installations from fault current to earth, serving as a core safety device in single-phase distribution circuits.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: F202 AC-40\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202001R1400\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542780106\u003c\/li\u003e\n\u003cli\u003ePoles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eResidual current type: Type AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtects people and electrical installations against fault current to earth, combining personal safety and installation protection in a single device\u003c\/li\u003e\n\u003cli\u003e30 mA trip sensitivity provides earth fault detection at the level required for personal protection\u003c\/li\u003e\n\u003cli\u003e2-pole design isolates both conductors simultaneously on detection of a fault, appropriate for single-phase circuits\u003c\/li\u003e\n\u003cli\u003ePart of the wide F200 series offer, which spans standard instantaneous and selective variants across AC and A types to cover a broad range of installation requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePersonal protection on final circuits in residential consumer units and distribution boards\u003c\/li\u003e\n\u003cli\u003eEarth leakage protection for socket outlet and fixed equipment circuits\u003c\/li\u003e\n\u003cli\u003eSingle-phase circuits in light commercial and small industrial installations\u003c\/li\u003e\n\u003cli\u003eAny application calling for Type AC earth fault protection at up to 40 A rated current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB F202 AC-40\/0.03, F202 AC-40\/0.03 2CSF202001R1400, ABB RCCB 2-pole 40 A 30 mA, ABB residual current circuit breaker 40 A Type AC, F200 series RCCB 2P.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021361928,"sku":"ABB2CSF202001R1400","price":33.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202001r1400-f202-ac-40003-residual-current-circuit-breaker-2p-ac-type-30-ma-350485.png?v=1735225740"},{"product_id":"2csf202001r1630-f202-ac-63-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202001R1630 F200 RCBO 1P+N 202 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB F202 AC-63\/0.03 (article 2CSF202001R1630) is a 2-pole residual current circuit breaker (RCCB) from ABB's F200 series, rated at 63 A with a residual current sensitivity of 30 mA. It is built to protect both people and electrical installations against earth fault currents. The Type AC designation means it responds to sinusoidal alternating residual currents.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: F202 AC-63\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202001R1630\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542780205\u003c\/li\u003e\n\u003cli\u003ePoles: 2P (2-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 63 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eResidual current type: Type AC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e30 mA tripping threshold offers personal protection against electric shock caused by earth fault currents\u003c\/li\u003e\n\u003cli\u003e63 A rated current accommodates higher-load single-phase circuits\u003c\/li\u003e\n\u003cli\u003e2-pole configuration suits single-phase distribution applications\u003c\/li\u003e\n\u003cli\u003eType AC detection responds to sinusoidal alternating residual currents as found in standard AC installations\u003c\/li\u003e\n\u003cli\u003ePart of the F200 series, which covers both instantaneous and selective variants as well as configurations for special applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eResidential and light commercial distribution boards requiring earth fault protection\u003c\/li\u003e\n\u003cli\u003eSingle-phase final circuits loaded up to 63 A\u003c\/li\u003e\n\u003cli\u003eInstallations where protection of people against indirect contact is required\u003c\/li\u003e\n\u003cli\u003eCircuits calling for Type AC residual current protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB F202 AC-63\/0.03, F202 AC-63\/0.03 2CSF202001R1630, ABB 2CSF202001R1630, 2-pole RCCB 63 A 30 mA Type AC, ABB residual current circuit breaker 63A.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021394696,"sku":"ABB2CSF202001R1630","price":51.52,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202001r1630-f202-ac-63003-residual-current-circuit-breaker-2p-ac-type-30-ma-868989.jpg?v=1735225739"},{"product_id":"2csf202004r1250-fh202-ac-25-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202004R1250 F200 RCBO 1P+N 202 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB FH202 AC-25\/0.03 (article 2CSF202004R1250) is a 2-pole residual current circuit breaker (RCCB) from the FH200 series, rated at 25 A with a 30 mA earth fault sensitivity. It detects fault currents flowing to earth and trips instantaneously to protect both people and electrical installations. This Type AC variant responds to sinusoidal alternating residual currents and is designed for standard domestic applications.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: FH202 AC-25\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202004R1250\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542893608\u003c\/li\u003e\n\u003cli\u003eType: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current: 25 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTrip characteristic: Type AC - standard instantaneous, sinusoidal AC residual current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30 mA sensitivity offers effective personal protection against earth leakage fault current\u003c\/li\u003e\n\u003cli\u003eInstantaneous tripping provides fast disconnection the moment a fault current to earth is detected\u003c\/li\u003e\n\u003cli\u003e2-pole design switches both live and neutral conductors in single-phase circuits\u003c\/li\u003e\n\u003cli\u003eType AC classification covers sinusoidal AC residual currents as found in standard domestic loads\u003c\/li\u003e\n\u003cli\u003ePart of the FH200 series, developed for domestic installation environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eSocket outlet and lighting circuits in homes and apartments\u003c\/li\u003e\n\u003cli\u003eBathroom, kitchen, and outdoor circuits where personal protection is required\u003c\/li\u003e\n\u003cli\u003eSingle-phase domestic wiring requiring earth fault protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso known as: ABB FH202 AC-25\/0.03, FH202 AC-25\/0.03 2CSF202004R1250, ABB RCCB 2P 25A 30mA Type AC, residual current circuit breaker 25A 30mA, ABB 2CSF202004R1250.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021427464,"sku":"ABB2CSF202004R1250","price":18.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202004r1250-fh202-ac-25003-residual-current-circuit-breaker-2p-ac-type-30-ma-336980.png?v=1735225732"},{"product_id":"2csf202004r1400-fh202-ac-40-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB FH202 AC-40\/0.03 2-Pole Residual Current Circuit Breaker (40 A","description":"\u003cp\u003eThe ABB FH202 AC-40\/0.03 (article 2CSF202004R1400) is a 2-pole residual current circuit breaker from the FH200 series, rated at 40 A with a 30 mA residual current trip threshold. It is built to guard people and electrical installations against earth fault currents, and is designed as a standard instantaneous Type AC device for domestic wiring applications.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: FH202 AC-40\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202004R1400\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542893707\u003c\/li\u003e\n\u003cli\u003eManufacturer: ABB\u003c\/li\u003e\n\u003cli\u003ePoles: 2P (2-pole)\u003c\/li\u003e\n\u003cli\u003eRated current: 40 A\u003c\/li\u003e\n\u003cli\u003eResidual current sensitivity: 30 mA\u003c\/li\u003e\n\u003cli\u003eTripping type: AC (sinusoidal alternating residual currents)\u003c\/li\u003e\n\u003cli\u003eOperation: standard instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e30 mA trip threshold provides personal protection against indirect contact with live conductors\u003c\/li\u003e\n\u003cli\u003e2-pole format protects both line and neutral conductors on single-phase circuits\u003c\/li\u003e\n\u003cli\u003eType AC response covers sinusoidal AC earth fault currents, the standard requirement for most domestic circuits\u003c\/li\u003e\n\u003cli\u003eInstantaneous operation trips the circuit without intentional time delay on detection of a fault current\u003c\/li\u003e\n\u003cli\u003ePart of the broad FH200 family, sized and specified for installation in residential distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDomestic consumer units and distribution boards in homes and apartments\u003c\/li\u003e\n\u003cli\u003eSingle-phase final circuits requiring personal shock protection\u003c\/li\u003e\n\u003cli\u003eBathroom, kitchen, and utility room circuits where earth fault protection is mandatory\u003c\/li\u003e\n\u003cli\u003eGeneral residential wiring installations where a standard Type AC RCCB is specified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB FH202 AC-40\/0.03, FH202 AC-40\/0.03 2CSF202004R1400, ABB RCCB 40A 30mA 2-pole Type AC, residual current circuit breaker 40 A 30 mA, ABB earth leakage circuit breaker FH200.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021558536,"sku":"ABB2CSF202004R1400","price":20.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202004r1400-fh202-ac-40003-residual-current-circuit-breaker-2p-ac-type-30-ma-223431.png?v=1735225732"},{"product_id":"2csf202004r1630-fh202-ac-63-0-03-residual-current-circuit-breaker-2p-ac-type-30-ma","title":"ABB 2CSF202004R1630 F200 RCBO 1P+N 202 A 30mA DIN Rail","description":"\u003cp\u003eThe ABB FH202 AC-63\/0.03 (article 2CSF202004R1630) is a 2-pole 63 A residual current circuit breaker from the ABB FH200 series, offering a 30 mA residual current sensitivity and a Type AC tripping characteristic. It is built to protect both people and electrical installations from earth fault currents. This RCCB is particularly suited to domestic wiring and distribution applications.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSeries: FH202 AC-63\/0.03\u003c\/li\u003e\n\u003cli\u003eABB article number: 2CSF202004R1630\u003c\/li\u003e\n\u003cli\u003eEAN: 8012542893806\u003c\/li\u003e\n\u003cli\u003eDevice type: Residual Current Circuit Breaker (RCCB)\u003c\/li\u003e\n\u003cli\u003eNumber of poles: 2P\u003c\/li\u003e\n\u003cli\u003eRated current: 63 A\u003c\/li\u003e\n\u003cli\u003eResidual operating current: 30 mA\u003c\/li\u003e\n\u003cli\u003eTripping type: AC - instantaneous\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e2-pole design disconnects both conductors on a fault, providing full isolation of the protected circuit\u003c\/li\u003e\n\u003cli\u003e30 mA residual operating current protects people against earth fault currents\u003c\/li\u003e\n\u003cli\u003e63 A rated current suits high-load final and sub-main circuit positions in domestic distribution boards\u003c\/li\u003e\n\u003cli\u003eInstantaneous Type AC tripping response addresses earth fault protection requirements in residential environments\u003c\/li\u003e\n\u003cli\u003ePart of the ABB FH200 series, designed specifically for domestic installation applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEarth fault protection in residential distribution boards and consumer units\u003c\/li\u003e\n\u003cli\u003eProtection of final circuits in domestic wiring installations\u003c\/li\u003e\n\u003cli\u003eSafeguarding people and installations against earth leakage in household electrical systems\u003c\/li\u003e\n\u003cli\u003eReplacement or upgrade of 2-pole 63 A Type AC RCCBs in domestic switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlso known as: ABB FH202 AC-63\/0.03, FH202 AC-63\/0.03 2CSF202004R1630, ABB 2CSF202004R1630, ABB 63 A 30 mA 2-pole RCCB, ABB FH200 RCCB Type AC.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44750021591304,"sku":"ABB2CSF202004R1630","price":32.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/2csf202004r1630-fh202-ac-63003-residual-current-circuit-breaker-2p-ac-type-30-ma-913844.png?v=1735225733"},{"product_id":"263577-pf7-25-2-003-de-residual-current-circuit-breaker-2p-25a-30ma-type-ac","title":"Eaton 263577 PF7-25\/2\/003-DE RCCB 2P 25 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF7-25\/2\/003-DE is a 2-pole Type AC RCCB from the Moeller xPole series, rated 25 A \/ 30 mA with a 10 kA Icn. Partly surge-proof to 250 A, it serves residential and commercial distribution installations.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF7-25\/2\/003-DE\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 263577\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082635770\u003c\/li\u003e\n  \u003cli\u003ePoles \/ leakage type: 2-pole, Type AC\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eFault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icn): 10 kA\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC, 50 Hz\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to +55 °C\u003c\/li\u003e\n  \u003cli\u003eStorage \/ transport temperature: -35 °C to +60 °C\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width \/ depth: 2 SU (35 mm) \/ 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail (IEC\/EN 60715), 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eTerminals: open-mouth lift, finger-safe per DGUV VS3, EN 50274\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (flexible): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid-core): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eMax. back-up fuse: 25 A gG\/gL (overload) \/ 63 A (short-circuit)\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 - 250 V AC\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 2 W\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations; electrical: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePartly surge-proof to 250 A reduces nuisance tripping caused by transient overvoltages\u003c\/li\u003e\n  \u003cli\u003eWide ambient range -25 °C to +55 °C suits demanding installation environments\u003c\/li\u003e\n  \u003cli\u003eFinger- and touch-safe terminals per DGUV VS3 and EN 50274 improve installer safety\u003c\/li\u003e\n  \u003cli\u003eDIN-rail snap-on with 2 latch positions enables fast, secure panel assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidual current protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial electrical installations requiring Type AC fault current detection\u003c\/li\u003e\n  \u003cli\u003eFinal circuits with 25 A rated current in domestic and light commercial premises\u003c\/li\u003e\n  \u003cli\u003ePanel assemblies where partial surge immunity limits nuisance disconnections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole series for residential and commercial switchgear.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF7-25\/2\/003-DE, Eaton 263577, Eaton catalog 263577, PF7 RCCB 25A 30mA.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44761458966792,"sku":"ETN263577","price":29.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/263577-pf7-252003-de-residual-current-circuit-breaker-2p-25a-30ma-type-ac-858957.jpg?v=1735225384"},{"product_id":"263584-pf7-25-4-003-de-residual-current-circuit-breaker-4p-25a-30ma-type-ac","title":"Eaton 263584 PF7-25\/4\/003-DE RCCB 4P 25 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF7-25\/4\/003-DE is a 4-pole Type AC RCCB from the Moeller xPole PF6\/7 series, designed for earth leakage protection in residential and commercial electrical installations. Rated at 25 A with a 30 mA fault current threshold and 10 kA short-time withstand current, it delivers reliable personnel and installation protection across 230 V AC and 400 V AC systems.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF7-25\/4\/003-DE\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 263584\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082635848\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 25 A\u003c\/li\u003e\n  \u003cli\u003eFault current (IN): 30 mA\u003c\/li\u003e\n  \u003cli\u003eLeakage current type: AC (Type AC)\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icn): 10 kA\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: 250 A (partly surge-proof)\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 V AC - 440 V AC\u003c\/li\u003e\n  \u003cli\u003eAdmissible back-up fuse: 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eDimensions (WxHxD): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 70 mm (4 SU)\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, 2 latch positions\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 55 °C\u003c\/li\u003e\n  \u003cli\u003eStorage and transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (solid): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor cross-section (multi-wire): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation: 3.1 W\u003c\/li\u003e\n  \u003cli\u003eTerminal type: Open mouthed\/lift terminals, EN 50274, DGUV VS3\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC current sensitivity with partial surge protection to 250 A reduces nuisance tripping from transient currents\u003c\/li\u003e\n  \u003cli\u003eQuick 2-position DIN rail latching enables fast, tool-free panel assembly\u003c\/li\u003e\n  \u003cli\u003eTouch-safe open mouthed\/lift terminals rated to EN 50274 and DGUV VS3 for safe field wiring\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-FW\/LP 248296 remote control device for automated or remote switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial switchgear panels and office electrical installations\u003c\/li\u003e\n  \u003cli\u003eSocket outlet and final circuit earth leakage protection\u003c\/li\u003e\n  \u003cli\u003eSwitchgear assemblies requiring supplementary sealing with Z-RC\/AK-4TE 101062\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008, RoHS conform. Part of the Eaton Moeller xPole PF6\/7 RCCB series for residential and commercial switchgear applications.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF7-25\/4\/003-DE, Eaton 263584, Eaton catalog 263584, Eaton model PF7-25\/4\/003-DE, Eaton xPole 25 A 4-pole RCCB 30 mA Type AC.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44761459032328,"sku":"ETN263584","price":36.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/263584-pf7-254003-de-residual-current-circuit-breaker-4p-25a-30ma-type-ac-272492.jpg?v=1735225384"},{"product_id":"263586-pf7-40-4-003-de-residual-current-circuit-breaker-4p-40a-30ma-type-ac","title":"Eaton 263586 PF7-40\/4\/003-DE RCCB 4P 40 A 30mA Type AC DIN Rail","description":"\u003cp\u003eThe Eaton PF7-40\/4\/003-DE is a 4-pole Type AC RCCB from the Moeller series xPole range, rated at 40 A with a 30 mA residual current threshold. Offering a 10 kA short-time withstand current and partial surge immunity up to 250 A, it is designed for earth fault protection in residential and commercial distribution systems operating on 230 V AC \/ 400 V AC networks.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF7-40\/4\/003-DE\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 263586\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082635862\u003c\/li\u003e\n  \u003cli\u003eNumber of poles: 4\u003c\/li\u003e\n  \u003cli\u003eRated current (In): 40 A\u003c\/li\u003e\n  \u003cli\u003eRated residual current (IN): 30 mA, Type AC\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (ICW): 10 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand current: partly surge-proof 250 A\u003c\/li\u003e\n  \u003cli\u003eVoltage rating: 230 V AC \/ 400 V AC\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n  \u003cli\u003eDegree of protection: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eAmbient operating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, IEC\/EN 60715, 4 SU (70 mm)\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 70 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.32 kg\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor, solid-core: 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eConnectable conductor, multi-wired: 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eMaximum admissible back-up fuse: 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eCertifications: IEC\/EN 61008, RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType AC detection responds to sinusoidal alternating residual currents for standard residential and commercial protection\u003c\/li\u003e\n  \u003cli\u003ePartial surge immunity rated at 250 A reduces nuisance tripping caused by transient currents\u003c\/li\u003e\n  \u003cli\u003eQuick DIN rail snap-fit with 2 latch positions for fast installation per IEC\/EN 60715\u003c\/li\u003e\n  \u003cli\u003eOpen mouthed\/lift terminals accept solid-core conductors up to 35 mm², enabling flexible wiring configurations\u003c\/li\u003e\n  \u003cli\u003eFinger and touch-safe terminal protection per EN 50274 and DGUV VS3 for safe on-site work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building main and sub-distribution panels\u003c\/li\u003e\n  \u003cli\u003eProtection of 3-phase and neutral circuits in 400 V AC systems\u003c\/li\u003e\n  \u003cli\u003eDIN rail panel assemblies with optional remote control via Z-FW\/LP 248296\u003c\/li\u003e\n  \u003cli\u003eInstallations requiring surge-resistant residual current protection in mixed environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller series xPole PF7 RCCB range.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF7-40\/4\/003-DE, Eaton 263586, Eaton catalog 263586, Eaton model PF7-40\/4\/003-DE, Eaton xPole 4-pole 40 A RCCB 30 mA Type AC.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44761459851528,"sku":"ETN263586","price":37.45,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/263586-pf7-404003-de-residual-current-circuit-breaker-4p-40a-30ma-type-ac-718791.jpg?v=1735225384"},{"product_id":"263602-pf7-25-2-003-de-residual-current-circuit-breaker-2p-40a-30ma-type-a","title":"Eaton 263602 PF7-40\/2\/003-A-DE RCCB 2P 40 A 30mA Type A DIN Rail","description":"\u003cp\u003eThe Eaton PF7-40\/2\/003-A-DE is a two-pole 40 A RCCB from the Moeller xPole series, rated 230 V AC at 50 Hz. Tripping at 30 mA with Type A pulse-current sensitivity, it protects against indirect contact and earth leakage in residential and commercial installations. Certified to IEC\/EN 61008 and RoHS compliant.\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eModel code: PF7-40\/2\/003-A-DE\u003c\/li\u003e\n  \u003cli\u003eCatalog number: 263602\u003c\/li\u003e\n  \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n  \u003cli\u003eEAN: 4015082636029\u003c\/li\u003e\n  \u003cli\u003ePoles: 2 (two-pole)\u003c\/li\u003e\n  \u003cli\u003eRated current: 40 A\u003c\/li\u003e\n  \u003cli\u003eVoltage: 230 V AC, 50 Hz\u003c\/li\u003e\n  \u003cli\u003eFault current: 30 mA, Type A, pulse-current sensitive\u003c\/li\u003e\n  \u003cli\u003eRated impulse withstand voltage (Uimp): 4 kV\u003c\/li\u003e\n  \u003cli\u003eRated short-time withstand current (Icw): 10 kA\u003c\/li\u003e\n  \u003cli\u003eImpulse withstand: 250 A (partly surge-proof)\u003c\/li\u003e\n  \u003cli\u003eMax. admissible back-up fuse: 25 A gG\/gL\u003c\/li\u003e\n  \u003cli\u003eShort-circuit rating: 63 A\u003c\/li\u003e\n  \u003cli\u003eFrame: 45 mm\u003c\/li\u003e\n  \u003cli\u003ePollution degree: 2\u003c\/li\u003e\n  \u003cli\u003eIP rating: IP20 (IP40 with suitable enclosure)\u003c\/li\u003e\n  \u003cli\u003eMounting: DIN rail, 2-latch positions, IEC\/EN 60715\u003c\/li\u003e\n  \u003cli\u003eBuilt-in width: 35 mm (2 SU), depth: 69.5 mm\u003c\/li\u003e\n  \u003cli\u003eDimensions (W x H x D): 35 x 80 x 76 mm\u003c\/li\u003e\n  \u003cli\u003eWeight: 0.22 kg\u003c\/li\u003e\n  \u003cli\u003eBusbar material thickness: 0.8 - 2 mm\u003c\/li\u003e\n  \u003cli\u003eConductor (multi-wired): 1.5 - 16 mm²\u003c\/li\u003e\n  \u003cli\u003eConductor (solid-core): 1.5 - 35 mm²\u003c\/li\u003e\n  \u003cli\u003eTerminals: open mouthed\/lift, touch-safe (DGUV VS3, EN 50274)\u003c\/li\u003e\n  \u003cli\u003eTest circuit range: 184 - 250 V AC\u003c\/li\u003e\n  \u003cli\u003eOperating temperature: -25 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eStorage\/transport temperature: -35 °C to 60 °C\u003c\/li\u003e\n  \u003cli\u003eClimatic proofing: 25-55 °C \/ 90-95% RH (IEC 60068-2)\u003c\/li\u003e\n  \u003cli\u003eHeat dissipation (current-dependent): 5.8 W\u003c\/li\u003e\n  \u003cli\u003eMechanical lifespan: 20,000 operations\u003c\/li\u003e\n  \u003cli\u003eElectrical lifespan: 4,000 operations\u003c\/li\u003e\n  \u003cli\u003eCertification: IEC\/EN 61008\u003c\/li\u003e\n  \u003cli\u003eCompliance: RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eType A sensitivity detects sinusoidal and pulsating DC residual currents, covering modern electronic and mixed loads\u003c\/li\u003e\n  \u003cli\u003eWide operating range -25 °C to 60 °C; current rating derated 2.5% per 1 °C above 40 °C\u003c\/li\u003e\n  \u003cli\u003eTouch-safe terminals (DGUV VS3, EN 50274) minimize shock risk during installation and maintenance\u003c\/li\u003e\n  \u003cli\u003eQuick two-position DIN rail latching for fast assembly and removal in xPole panels\u003c\/li\u003e\n  \u003cli\u003eExpandable with remote control Z-FW\/LP 248296, sealing cover Z-RC\/AK-2TE 285385, and tripping signal contact Z-NHK 248434\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eResidual current protection in residential consumer units and distribution boards\u003c\/li\u003e\n  \u003cli\u003eEarth leakage protection in commercial switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003exPole installations with compact enclosures such as KLV-TC-2 276240\u003c\/li\u003e\n  \u003cli\u003eSupplementary protection for circuits supplying electronic equipment and mixed loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompliant with IEC\/EN 61008. Part of the Eaton Moeller xPole series for residential and commercial switchgear.\u003c\/p\u003e\n\u003cp\u003eAlso known as: Eaton PF7-40\/2\/003-A-DE, Eaton 263602, Eaton catalog 263602, Eaton model PF7-40\/2\/003-A-DE, Eaton xPole RCCB 40A 30mA Type A.\u003c\/p\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":44761459884296,"sku":"ETN263602","price":28.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/263602-pf7-252003-de-residual-current-circuit-breaker-2p-40a-30ma-type-a-772332.jpg?v=1735225385"},{"product_id":"411005-dx-residual-current-circuit-breaker-1p-n-32a-30ma-230v-ac-type","title":"Legrand 411005 RCBO DX³ 6000 10kA 1P+N 230V~ 32A 30mA Type AC N right","description":"\u003cp\u003eThe Legrand 411005 is part of the DX³ LEGRAND RCBO range. RCBO DX³ 6000 10kA 1P+N 230V~ 32A 30mA Type AC N right.\u003c\/p\u003e\u003cp\u003eTechnical specifications:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCatalog reference: 411005\u003c\/li\u003e\n\u003cli\u003eManufacturer: Legrand\u003c\/li\u003e\n\u003cli\u003eEAN: 3245064110051\u003c\/li\u003e\n\u003cli\u003eproduct type: RCBO (Residual Current Circuit Breaker with Overcurrent protection)\u003c\/li\u003e\n\u003cli\u003enumber of poles total: 2\u003c\/li\u003e\n\u003cli\u003enumber of protected poles: 1\u003c\/li\u003e\n\u003cli\u003eRated voltage: 230 V\u003c\/li\u003e\n\u003cli\u003eRated current (In): 32 A\u003c\/li\u003e\n\u003cli\u003eRated residual current (IΔn): 0.03 A\u003c\/li\u003e\n\u003cli\u003eResidual current type: AC\u003c\/li\u003e\n\u003cli\u003ecurrent limiting class: 3\u003c\/li\u003e\n\u003cli\u003erated short circuit breaking capacity iec 61009: 6 kA\u003c\/li\u003e\n\u003cli\u003erated short circuit breaking capacity iec 60947 2: 10 kA\u003c\/li\u003e\n\u003cli\u003eSurge current capacity: 0.25 kA\u003c\/li\u003e\n\u003cli\u003eVoltage type: AC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50 Hz\u003c\/li\u003e\n\u003cli\u003erelease characteristic: C\u003c\/li\u003e\n\u003cli\u003econcurrently switching neutral: Yes\u003c\/li\u003e\n\u003cli\u003eInterlocking device: Yes\u003c\/li\u003e\n\u003cli\u003ePollution degree: 2\u003c\/li\u003e\n\u003cli\u003eWidth (modules): 2\u003c\/li\u003e\n\u003cli\u003ebuilt in depth mm: 44\u003c\/li\u003e\n\u003cli\u003eDegree of protection (IP): IP20\u003c\/li\u003e\n\u003cli\u003econnectable conductor solid core: 0.75-16 mm²\u003c\/li\u003e\n\u003cli\u003econnectable conductor multi wired: 0.75-10 mm²\u003c\/li\u003e\n\u003cli\u003eMounting: DIN rail\u003c\/li\u003e\n\u003cli\u003eneutral position: Right\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFeatures and benefits:\u003c\/p\u003e\u003cul\u003e\u003cli\u003eManufactured by Legrand for professional electrical installations.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eApplications:\u003c\/p\u003e\u003cul\u003e\u003cli\u003eProfessional electrical installations using the DX³ LEGRAND RCBO range.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eAlso known as: Legrand 411005, 411005, DX³ LEGRAND RCBO.\u003c\/p\u003e","brand":"LEGRAND","offers":[{"title":"Default Title","offer_id":50221903708424,"sku":"LGR411005","price":33.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/4351\/3096\/files\/411005-dx3-residual-current-circuit-breaker-1pn-32a-30ma-230v-ac-type-161004.jpg?v=1735226576"}],"url":"https:\/\/gabbyelectric.com\/en-ca\/collections\/residual-current-circuit-breakers.oembed?page=5","provider":"Gabby Electric","version":"1.0","type":"link"}